Switchgear, GIS and ring main units
Medium-voltage switchgear, gas-insulated switchgear and ring main units for substations and industry. 106 items.
Low-voltage versions (up to 1000 V) — on ukrsk.com.ua: Switchgear and package substations

Switchgear, GIS and ring main units24 kV air-insulated MV switchgear, line and transformer cubicles 500 mm, 630 A busbars

Switchgear, GIS and ring main unitsIndoor MV switchgear to 24 kV for substations, 350 or 630 A busbars, cubicles from 690 mm

Switchgear, GIS and ring main unitsSF₆-free 12 kV switchgear with vacuum breakers and magnetic actuator, 630–2000 A, 25 kA

Switchgear, GIS and ring main unitsFactory-built SF₆-free MV containerised substations, EV PowerSub 36/12 kV version

Switchgear, GIS and ring main unitsCompact extensible gas-insulated switchgear, 24 or 36 kV, 400 or 630 A

Switchgear, GIS and ring main unitsModular air-insulated MV switchgear, 12–36 kV, 400 and 630 A, up to 20 kA

Switchgear, GIS and ring main unitsExtensible concrete sectioning point for rural MV cable networks

Switchgear, GIS and ring main unitsCompact extensible gas-insulated switchgear, 24 kV, 400 A, SF6 insulation

Switchgear, GIS and ring main unitsAir-insulated switchgear 12–24 kV, 630 A, with load-break switches and fuses

Switchgear, GIS and ring main unitsModular outdoor switchgear for railway power supply up to 25 kV, up to 2000 A

Switchgear, GIS and ring main unitsCompact SF6-free 12 and 24 kV switchgear, synthetic ester insulation, 240 mm panel pitch

Switchgear, GIS and ring main unitsAir-insulated 36 kV switchgear without SF6, up to 2000 A, 31.5 kA / 3 s, IP3X, LSC2A

Switchgear, GIS and ring main unitsAir-insulated 12 and 24 kV switchgear, up to 630 A (W12) and 1250–1600 A (W24)

Switchgear, GIS and ring main units12 and 24 kV switchgear with withdrawable vacuum breakers, up to 2500 A, up to 31.5 kA

Switchgear, GIS and ring main unitsCompact air-insulated 12 and 24 kV switchgear, 630 A, up to 20 kA 1 s, IP3X

Switchgear, GIS and ring main unitsPackaged transformer and transfer substations up to 36 kV, compact and walk-in

Switchgear, GIS and ring main unitsSF6-free ring main unit (RMU) monobloc up to 24 kV with gas insulation

Switchgear, GIS and ring main unitsGas-insulated ring main unit (RMU) up to 36 kV for secondary networks

Switchgear, GIS and ring main unitsSF6-free medium-voltage gas-insulated switchgear up to 36 kV for primary distribution

Switchgear, GIS and ring main unitsMedium-voltage metal-clad switchgear up to 24 kV with air insulation

Switchgear, GIS and ring main unitsModular air-insulated switchgear up to 36 kV for secondary distribution

Switchgear, GIS and ring main unitsMetal-clad air-insulated switchgear 36 kV, up to 4000 A, 50 kA

Switchgear, GIS and ring main unitsCompact MV network sectionalising station with remote control, RMU up to 6 modules

Switchgear, GIS and ring main unitsCubicle SF6 switchgear 25.8 kV, busbars up to 2000 A, withstand up to 25 kA 1 s

Switchgear, GIS and ring main unitsSolid insulated switchgear with draw-out vacuum breaker 15 and 25.8 kV, 630 and 1250 A

Switchgear, GIS and ring main units72.5–170 kV GIS on SF6 and eco-gas, hybrid MTS 145 kV, up to 4000 A and 50 kA

Switchgear, GIS and ring main unitsModular solid insulated secondary switchgear, 12.5 kA, automatic transfer in 1 cycle

Switchgear, GIS and ring main unitsDC switchgear 750/1500 V for currents up to 6000 A for traction substations

Switchgear, GIS and ring main unitsSF6 RMU monoblock 17.5 and 24 kV, 21 kA 3 s, gas leakage below 0.1 % over 30 years

Switchgear, GIS and ring main unitsPad-Mount switchgear 15 and 27 kV, 12.5 kA 1 s, submersible LBS 25.8 kV IPX8

Switchgear, GIS and ring main unitsSolid insulated substation switchgear 15–40.5 kV, up to 2500 A, 25–40 kA

Switchgear, GIS and ring main units12 kV solid insulated RMU monoblock without SF6, 20 kA 3 s, 52 kA

Switchgear, GIS and ring main unitsGIS 72–300 kV and cubicle-type GIS 24 and 72 kV for power systems and railways

Switchgear, GIS and ring main unitsCubicle gas-insulated medium voltage switchgear up to 38 kV, 25–40 kA

Switchgear, GIS and ring main unitsGas-insulated high and extra-high voltage switchgear 72.5–800 kV

Switchgear, GIS and ring main unitsAir-insulated medium voltage switchgear 4.76–38 kV, up to 4000 A, up to 50 kA

Switchgear, GIS and ring main unitsRing main unit monoblocks (RMU) 7.2–24 kV, 630 A, 21 kA

Switchgear, GIS and ring main unitsHigh-voltage gas-insulated switchgear 72.5–800 kV with SF6 insulation

Switchgear, GIS and ring main unitsMetal-clad medium-voltage switchgear 12–24 kV, 630–4000 A

Switchgear, GIS and ring main unitsGas-insulated medium-voltage switchgear 24–38 kV, 630–4000 A

Switchgear, GIS and ring main unitsModular and compact SF6 secondary distribution switchgear 12, 24, 36 kV, up to 630 A

Switchgear, GIS and ring main unitsSF6-free 24/36 kV secondary switchgear, dry air at 0.2 bar, 630 A, 20 kA 3 s

Switchgear, GIS and ring main unitsConcrete packaged transformer substations 12, 24, 36 kV from 1×50 to 2×1250 kVA

Switchgear, GIS and ring main unitsIntegrated inverter + transformer + MV switchgear platform 24/36 kV up to 10 MVA for PV

Switchgear, GIS and ring main unitsCubicle gas-insulated MV switchgear for 25.8 and 36 kV, breaking current up to 40 kA

Switchgear, GIS and ring main unitsSF6 GIS 72.5–420 kV up to 4000 A and 50 kA, eco-friendly g3 GIS for 170 kV

Switchgear, GIS and ring main unitsSF6 ring main units for 12, 17.5 and 24 kV, busbars 630 A, 21 kA / 3 s

Switchgear, GIS and ring main unitsMetal-clad MV switchgear 7.2–36 kV with withdrawable vacuum breakers, to 4000 A and 50 kA

Switchgear, GIS and ring main unitsSF6-insulated RMU up to 38 kV, 630 A, for networks, wind and solar plants

Switchgear, GIS and ring main units12 kV RMU with synthetic air insulation and front cable entry

Switchgear, GIS and ring main unitsSF6-insulated RMU 12–24 kV, up to 630 A, with built-in RTU

Switchgear, GIS and ring main unitsPrimary air-insulated GIS without SF6 up to 36 kV

Switchgear, GIS and ring main unitsRMU with synthetic air insulation up to 17.5 kV, SF6-free

Switchgear, GIS and ring main unitsSF6-insulated RMU up to 24 kV, up to 630 A, with side or rear cable entry

Switchgear, GIS and ring main unitsFuse-switch RMU up to 17.5 kV, up to 630 A

Switchgear, GIS and ring main unitsOil-insulated fused RMU up to 15.5 kV, 630 A

Switchgear, GIS and ring main unitsGas-insulated primary distribution switchgear 24/36 kV (ANSI 27/38 kV), up to 2000 A

Switchgear, GIS and ring main unitsPrimary distribution switchgear 24/36 kV with single or double busbar, up to 2500 A

Switchgear, GIS and ring main units52 kV, 630 A gas-insulated units for MV networks of solar plants and renewable sites

Switchgear, GIS and ring main units52 kV primary distribution switchgear with single or double busbar, up to 2000 A

Switchgear, GIS and ring main unitsModular and compact secondary switchgear up to 38.5 kV, 630 A for wind, solar and grids

Switchgear, GIS and ring main units72.5 kV, 1250 A switchgear with vacuum breaker for substations in modular buildings

Switchgear, GIS and ring main unitsCubicle GIS 12/24 kV, busbars 630/1250 A, 25 kA, SF6 or dry-air insulation

Switchgear, GIS and ring main unitsCubicle GIS 24/36 kV, 630–2500 A, up to 40 kA 3 s, single and double busbar system

Switchgear, GIS and ring main unitsAir-insulated withdrawable switchgear for 7.2–15 kV, busbars up to 3150 A, up to 40 kA

Switchgear, GIS and ring main unitsGas-insulated switchgear for voltages of 72–1100 kV

Switchgear, GIS and ring main unitsCompact gas-insulated secondary distribution switchgear up to 40.5 kV, 630 A, 25 kA

Switchgear, GIS and ring main unitsModular gas-insulated switchgear up to 36/38 kV with increased 800 A current, 25 kA

Switchgear, GIS and ring main unitsSF6-free modular secondary distribution switchgear up to 24 kV, 630 A, 20 kA

Switchgear, GIS and ring main unitsCompact modular fully gas-insulated switchgear up to 24/27 kV, 630 A, 25 kA

Switchgear, GIS and ring main unitsGas-insulated single busbar primary switchgear up to 24 kV, 2000 A, 25 kA

Switchgear, GIS and ring main unitsGas-insulated single busbar primary switchgear up to 40.5 kV, 2500 A, 31.5 kA

Switchgear, GIS and ring main unitsGas-insulated double busbar switchgear up to 36 kV, 2000 A, 31.5 kA

Switchgear, GIS and ring main unitsCompact gas-insulated secondary distribution switchgear up to 24 kV, 630 A, 20 kA

Switchgear, GIS and ring main unitsFluorine-free primary distribution single-busbar switchgear up to 24 kV, 1600 A, 25 kA

Switchgear, GIS and ring main unitsModular MV switchgear with screened solid insulation up to 17.5 kV, 1250 A

Switchgear, GIS and ring main unitsIndoor air-insulated switchgear with vacuum breakers up to 36 kV, IAC A FLR to 31.5 kA

Switchgear, GIS and ring main unitsGas-insulated secondary distribution switchgear and RMU up to 24 and 36 kV, 630 A busbars

Switchgear, GIS and ring main unitsANSI switchgear with withdrawable vacuum breakers up to 27 kV, breaking up to 63 kA

Switchgear, GIS and ring main unitsAir-insulated switchgear 24–36 kV, up to 31.5 kA, busbars up to 2500 A

Switchgear, GIS and ring main unitsAir-insulated switchgear with withdrawable vacuum breakers up to 17.5 kV, 40/50 kA, 4000 A

Switchgear, GIS and ring main unitsMedium-voltage gas-insulated switchgear 7.2–38 kV, up to 31.5 kA, busbars up to 2500 A

Switchgear, GIS and ring main unitsANSI switchgear with load-break switches and vacuum breaker, 5 and 15 kV, up to 1200 A

Switchgear, GIS and ring main unitsSecondary distribution switchgear up to 24 kV, 25 kA (2 s), busbars and feeders 1250 A

Switchgear, GIS and ring main unitsSF6 GIS 72.5–245 kV, up to 300 kV offshore, breaking current up to 63 kA

Switchgear, GIS and ring main unitsSF6 GIS 245–550 kV, breaking current up to 80 kA, busbars up to 6300 A

Switchgear, GIS and ring main unitsCompact SF6-free 72.5 kV GIS for wind turbines and substations, up to 3000 A and 50 kA

Switchgear, GIS and ring main unitsSF6-free 145 kV GIS, vacuum circuit breakers, up to 3150 A and 50 kA

Switchgear, GIS and ring main unitsMV switchgear 7.2–40.5 kV for substations, busbars up to 4000 A, up to 63 kA

Switchgear, GIS and ring main unitsGenerator switchgear 12/15/17.5 kV, busbars up to 7000 A, up to 72 kA, LSC 2B

Switchgear, GIS and ring main unitsTraction power switchgear 17.5 kV 16.7 Hz, busbars up to 2552 A, 40 kA, IAC AFLR

Switchgear, GIS and ring main unitsGas-insulated switchgear and RMU 12–72.5 kV to 3150 A for MV networks and wind farms

Switchgear, GIS and ring main unitsWithdrawable switchgear 3.6–40.5 kV to 5000 A, VTB vacuum and pole-mounted breakers

Switchgear, GIS and ring main unitsCompact combined HGIS apparatus 40.5–126 kV up to 3150 A for solar and wind substations

Switchgear, GIS and ring main unitsSF6 GIS 126–550 kV up to 6300 A and 63 kA, SF6/N2 and clean-air designs

Switchgear, GIS and ring main unitsSIS switchgear 24–72 kV, C-GIS, GIS and gas circuit breakers for traction substations

Switchgear, GIS and ring main unitsMV starters, MCC, arc-resistant MCC and soft starters for induction and synchronous motors

Switchgear, GIS and ring main unitsGIS up to 550 kV, turnkey substations up to 800 kV, SF₆-free AEROXIA on natural gases

Switchgear, GIS and ring main unitsAir-insulated switchgear with vacuum circuit breakers 36 kV, 31.5 kA, busbars up to 2500 A

Switchgear, GIS and ring main unitsAir-insulated medium-voltage switchgear 12 and 24 kV, busbars up to 3150 A, SF6-free

Switchgear, GIS and ring main unitsMedium-voltage busbar trunking 12/24 kV, 2000 A, linking two rows of VECTOR switchgear

Switchgear, GIS and ring main unitsAir-insulated MV switchgear 2.3–36 kV, up to 4000 A and 50 kA, withdrawable devices

Switchgear, GIS and ring main unitsWithdrawable medium-voltage switchgear 12–36 kV, 630–4000 A

Switchgear, GIS and ring main unitsModular air-insulated medium-voltage switchgear up to 25 kV, 630 A

Switchgear, GIS and ring main unitsMonobloc MV ring main unit (RMU) up to 25 kV, 630 A, SF6 or air insulated

Switchgear, GIS and ring main unitsMV cable connection point in a concrete enclosure with TPM SF6 switchgear
Other sections
Power transformers and autotransformersOil-immersed distribution transformersDry-type transformersSpecial transformersTap changers and transformer fittingsBushings and insulated busductsPackaged substations and MV stationsCircuit breakers, disconnectors and reclosersInsulators and hardware for overhead lines and substationsCables, wires and cable accessoriesSurge arrestersReactors and arc suppression coilsReactive power compensation and STATCOMInstrument transformersProtection relays and substation automationMonitoring and diagnosticsTest and reference equipment
