International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

RELF / RELF 2S — withdrawable medium-voltage switchgear up to 36 kV

RELF and RELF 2S are primary distribution switchgear of metal-clad design with withdrawable elements and air insulation for 12 kV, 17.5 kV, 24 kV or 36 kV. The busbar and incomer current is 630–4000 A. They are installed at industrial substations and main step-down substations.

Rated voltage
12; 17.5; 24; 36 kV (RELF 2S — 12 kV)
Busbar and incomer current
630–4000 A
Design
metal-clad, withdrawable, air insulation; RELF 2S — double busbar system
Degree of protection
IP4X

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The withdrawable module is fitted with a circuit breaker, contactor, disconnector or voltage transformers. The RELF 2S modification has a double busbar system and is rated for 12 kV. Enclosure protection is IP4X. The devices comply with IEC 62271-200, IEC 62271-1 and GOST. Such switchgear is installed on substation incomers and feeders where an apparatus must be replaced quickly without dismantling the cell.

Technical specifications

Rated voltage12; 17.5; 24; 36 kV (RELF 2S — 12 kV)
Busbar and incomer current630–4000 A
Designmetal-clad, withdrawable, air insulation; RELF 2S — double busbar system
Degree of protectionIP4X
StandardsIEC 62271-200, IEC 62271-1, GOST

Request a price and lead time

RELF / RELF 2S — withdrawable medium-voltage switchgear up to 36 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
HS, 6 digits8537 20
CN (EU)8537 20 91
HTSUS (USA)8537 20 00 20
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltages is RELF available for?

RELF is available for 12 kV, 17.5 kV, 24 kV and 36 kV, the RELF 2S modification for 12 kV.

Which apparatus can be installed in the withdrawable module?

A circuit breaker, contactor, disconnector or voltage transformers. The busbar and incomer current is 630–4000 A.

Which standards does RELF comply with?

IEC 62271-200, IEC 62271-1 and GOST. The degree of protection is IP4X.

Similar equipment from other manufacturers