Reactors and arc suppression coils
Shunt, series and current-limiting reactors, neutral grounding and arc suppression (Petersen) coils. 48 items.

Reactors and arc suppression coilsLine traps for power line carrier communication, band 40–500 kHz, 50/60 Hz networks

Reactors and arc suppression coilsShunt reactors for compensating the charging power of power lines and cables

Reactors and arc suppression coilsEarthing transformers and single-phase transformers for networks and railway traction

Reactors and arc suppression coilsNeutral coils, compensating impedances and homopolar generators for 7.2–36 kV MV networks

Reactors and arc suppression coilsMV current-limiting reactors for capacitor banks, 50–200 A, 30–450 µH

Reactors and arc suppression coilsDry filter reactors for MV/HV filter-compensating units and HVDC

Reactors and arc suppression coilsDry air-core current-limiting reactor for HV and EHV networks up to 765 kV

Reactors and arc suppression coilsDry shunt reactor for direct connection to HV and EHV networks

Reactors and arc suppression coilsDry reactors for HVDC lines and back-to-back links

Reactors and arc suppression coilsHigh-frequency line trap for HV overhead lines, a reactor with a tuning element

Reactors and arc suppression coilsDry shunt reactor for MV networks up to 60 kV and tertiary transformer windings

Reactors and arc suppression coilsDry neutral grounding reactor for MV and HV transformer neutrals

Reactors and arc suppression coilsDry reactors for high-voltage and high-power test laboratories

Reactors and arc suppression coilsDry arc suppression reactor for compensated-neutral networks

Reactors and arc suppression coilsContinuously adjustable arc suppression reactors 6–110 kV, 125–19000 kVA

Reactors and arc suppression coilsGrounding transformers 6–52 kV, 200–8000 kVA

Reactors and arc suppression coilsNeutral grounding resistors for MV distribution networks, outdoor installation

Reactors and arc suppression coilsAuxiliary resistors for arc-suppression reactors in compensated networks

Reactors and arc suppression coilsThree-phase oil-immersed shunt reactors 6–35 kV, up to 8000 kVA

Reactors and arc suppression coilsMV protective filter and resonant reactors to 24 kV and 3,000 kVA for capacitor banks

Reactors and arc suppression coilsThree-phase MV shunt reactors with a magnetic core, 50–1,000 kvar, 3–20 kV

Reactors and arc suppression coilsAir-core MV current-limiting reactors without a magnetic core, up to 15.75 kV and 2,000 A

Reactors and arc suppression coilsSingle-phase air-core MV damping reactors up to 36 kV and 500 A for capacitor banks

Reactors and arc suppression coilsShunt reactors up to 765 kV and 250 MVAr, fixed and variable

Reactors and arc suppression coilsOil-immersed series reactors up to 245 kV and grounding transformers up to 170 kV

Reactors and arc suppression coilsDry-type reactors and chokes up to 36 kV, 1 kvar to several Mvar, AN, AF or WF cooling

Reactors and arc suppression coilsShunt reactors up to 800 kV, single-phase up to 110 Mvar, three-phase up to 300 Mvar

Reactors and arc suppression coilsShunt reactors up to 765 kV and 250 MVAr, fixed and VSR variable types

Reactors and arc suppression coilsEarthing and auxiliary transformers, example version ZT 500 kVA 34/0.4 kV

Reactors and arc suppression coilsReactors limiting short-circuit currents at substations and in industrial networks

Reactors and arc suppression coilsArc suppression coils and reactors for capacitive current compensation, MV

Reactors and arc suppression coilsEarthing and auxiliary transformers for substations and power plants

Reactors and arc suppression coilsOil-filled shunt reactors for reactive power compensation in HV networks

Reactors and arc suppression coilsDry-type reactors with cast resin or air insulation up to 15 Mvar, LI 200 kV

Reactors and arc suppression coilsOil-filled reactors and arc suppression coils up to 30/50 Mvar, insulation up to LI 750 kV

Reactors and arc suppression coilsArc suppression coils, neutral-forming and earthing transformers for MV networks

Reactors and arc suppression coilsOil-filled shunt reactors for high-voltage networks, 75 Mvar, 52.5 kV design

Reactors and arc suppression coilsShunt and series reactors for reactive power compensation in HV networks

Reactors and arc suppression coilsOil-immersed shunt reactors, 220–1000 kV, 60–320 Mvar

Reactors and arc suppression coilsDry-type air-core and iron-core reactors, 10–800 kV

Reactors and arc suppression coilsHV and EHV shunt reactors up to 500 kV for compensating line charging power

Reactors and arc suppression coilsDry-type smoothing and filter reactors for HVDC up to 1100 kV, up to 300 Mvar

Reactors and arc suppression coilsDry-type reactors for harmonic filters, SVC and FACTS up to 765 kV, up to 250 Mvar

Reactors and arc suppression coilsComplete earth-fault current compensation system for networks up to 36 kV, up to 15 Mvar

Reactors and arc suppression coilsArc suppression reactors with oil or ester fluid up to 145 kV, continuous adjustment

Reactors and arc suppression coilsDry-type air core shunt reactors up to 550 kV, rated up to 250 Mvar

Reactors and arc suppression coilsHF line traps for line communication up to 765 kV, short-circuit current up to 80 kA

Reactors and arc suppression coilsDry-type current-limiting series reactors up to 765 kV, BIL up to 2100 kV
Other sections
Power transformers and autotransformersOil-immersed distribution transformersDry-type transformersSpecial transformersTap changers and transformer fittingsBushings and insulated busductsPackaged substations and MV stationsSwitchgear, GIS and ring main unitsCircuit breakers, disconnectors and reclosersInsulators and hardware for overhead lines and substationsCables, wires and cable accessoriesSurge arrestersReactive power compensation and STATCOMInstrument transformersProtection relays and substation automationMonitoring and diagnosticsTest and reference equipment
