TKFC — three-phase shunt reactors 6–35 kV

TKFC three-phase oil-immersed shunt reactors for 6–35 kV networks with a rating of up to 8000 kVA. They compensate reactive (capacitive) power in distribution networks and at wind and solar plants.

Network voltage
6, 10, 15, 20, 35 kV
Rating
up to 8000 kVA
Connection
Y or YN
Adjustment
fixed rating or taps with an off-circuit tap changer

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The reactors are built for network voltages of 6, 10, 15, 20 and 35 kV, with a Y or YN connection. The rating is fixed or adjusted by taps with an off-circuit tap changer. The tank is hermetically sealed or has an oil conservator and a dehydrating breather, and cooling is by oil. Such a reactor is connected where cable networks produce excess capacitive power.

Technical specifications

Network voltage6, 10, 15, 20, 35 kV
Ratingup to 8000 kVA
ConnectionY or YN
Adjustmentfixed rating or taps with an off-circuit tap changer
Designhermetically sealed tank, or with oil conservator and dehydrating breather
Coolingoil

Replacement for

shunt reactors 6–35 kV — РОМ (generic type); controlled РТУ (generic type)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

TKFC — three-phase shunt reactors 6–35 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 50 00 90
HS, 6 digits8504 50
CN (EU)8504 50 00
HTSUS (USA)8504 50 80 00
China customs tariff8504 50 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What are the rating and voltage of the TKFC reactors?

A rating of up to 8000 kVA and a network voltage of 6, 10, 15, 20 or 35 kV.

Can the reactor rating be adjusted?

Yes, by taps with an off-circuit tap changer. A fixed-rating version is also available.

What tank design and cooling do they have?

A hermetically sealed tank or a tank with an oil conservator and a dehydrating breather, with oil cooling.