ZT — earthing transformers and auxiliary transformers
ZT transformers create an artificial neutral and supply the auxiliary loads of substations. Example version ZT 500 kVA 34/0.4 kV. They were supplied in large numbers for offshore wind farm platforms.
- Example version
- ZT 500 kVA 34/0.4 kV
- Purpose
- grounding of the network neutral and supply of auxiliary loads
- Application
- substations, including offshore wind farms
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The transformer combines grounding of the network neutral with the supply of the substation auxiliary loads. The HV side forms an artificial neutral in a network where there is none, and the LV winding feeds the auxiliary loads. They are used at substations, including offshore wind farm substations. The ZT 500 kVA 34/0.4 kV version is designed for a 34 kV network and supplies 0.4 kV consumers.
Technical specifications
| Example version | ZT 500 kVA 34/0.4 kV |
|---|---|
| Purpose | grounding of the network neutral and supply of auxiliary loads |
| Application | substations, including offshore wind farms |
Replacement for
ФМЗО, ТМПС (neutral-forming ZNyn 6–35 kV); auxiliary transformers: ТМ-…/10, ТМГ-100/10…ТМГ-250/10, ТСЗ-…/10, ТМ-…/35
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
ZT — earthing transformers and auxiliary transformers. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 23 00 00 |
|---|---|
| HS, 6 digits | 8504 21 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 23 00 |
| HTSUS (USA) | 8504 21 00 20 8504 21 00 40 8504 21 00 60 8504 21 00 80 8504 22 00 40 8504 22 00 80 8504 23 00 41 8504 23 00 45 8504 23 00 80 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 23 11 00 8504 23 12 00 8504 23 13 00 8504 23 21 00 8504 23 29 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
What is the ZT transformer used for?
It creates an artificial neutral of the network for its grounding and at the same time supplies the auxiliary loads of the substation.
What is a typical ZT version?
Example version ZT 500 kVA 34/0.4 kV.
Where are these transformers used?
At substations, including in large numbers on offshore wind farm platforms.