Air Core Shunt Reactors — dry-type shunt reactors up to 550 kV, 250 Mvar

Dry-type shunt reactors for voltages up to 550 kV and ratings up to 250 Mvar. They compensate the charging power of long, lightly loaded overhead and cable lines.

Voltage class
up to 550 kV
Rating
up to 250 Mvar
Design
dry, without a magnetic core, winding in an epoxy-fibreglass capsule
Connection
to the tertiary winding of an autotransformer, to the busbars or directly to the line

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The reactor is oil-free, so it needs no fire-extinguishing systems or bushings. The design is dry, without a magnetic core, and the winding is enclosed in an epoxy-fibreglass capsule. The reactor is connected to the tertiary winding of an autotransformer, to the busbars or directly to the line. The units are manufactured to IEC and ANSI/IEEE standards.

Technical specifications

Voltage classup to 550 kV
Ratingup to 250 Mvar
Designdry, without a magnetic core, winding in an epoxy-fibreglass capsule
Connectionto the tertiary winding of an autotransformer, to the busbars or directly to the line
StandardsIEC, ANSI/IEEE

Replacement for

oil-filled shunt reactors РОДЦ-60000/500, РОДЦ-110000/750; no direct analogue for dry-type HV units

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Air Core Shunt Reactors — dry-type shunt reactors up to 550 kV, 250 Mvar. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 50 00 90
HS, 6 digits8504 50
CN (EU)8504 50 00
HTSUS (USA)8504 50 80 00
China customs tariff8504 50 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What are the voltage and rating of the shunt reactors?

Up to 550 kV and up to 250 Mvar.

Where is a dry-type shunt reactor connected?

To the tertiary winding of an autotransformer, to the substation busbars or directly to the line.

Does the reactor need a fire-extinguishing system and bushings?

No, the reactor is oil-free and needs neither fire extinguishing nor bushings. The winding is in an epoxy-fibreglass capsule.