SR / SRA — auxiliary resistors for arc-suppression reactors

SR and SRA auxiliary (secondary) resistors for arc-suppression reactors in compensated networks. They briefly increase the active component of the earth-fault current so that directional earth-fault protection operates reliably.

Purpose
brief increase of the active component of the earth-fault current
Connection
to the power auxiliary winding of the arc-suppression reactor
SR
fixed resistance
SRA
set of resistor elements switched by contactors, controlled by the ARS-01 controller

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The resistor is connected to the power auxiliary winding of the arc-suppression reactor. The SR model has a fixed resistance. The SRA is assembled from a set of resistor elements switched by contactors on commands from the ARS-01 controller. Cooling is natural air and the installation is outdoor.

Technical specifications

Purposebrief increase of the active component of the earth-fault current
Connectionto the power auxiliary winding of the arc-suppression reactor
SRfixed resistance
SRAset of resistor elements switched by contactors, controlled by the ARS-01 controller
Coolingnatural air, outdoor installation

Replacement for

no direct analog; the closest are resistors for arc-suppression reactors РЗДПОМ (generic type)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

SR / SRA — auxiliary resistors for arc-suppression reactors. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8533 40 90 00
HS, 6 digits8533 40
CN (EU)8533 40 90
HTSUS (USA)8533 40 80 70
China customs tariff8533 40 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How do the SR and SRA resistors differ?

The SR has a fixed resistance. The SRA consists of a set of elements switched by contactors under the control of the ARS-01 controller.

Where is the auxiliary resistor connected?

To the power auxiliary winding of the arc-suppression reactor.

Why is an auxiliary resistor needed in a compensated network?

It briefly increases the active component of the earth-fault current, and the directional protection reliably identifies the faulted feeder.