Equipment for compensating capacitive earth-fault currents in medium-voltage networks. It includes arc suppression coils, neutral-forming transformers and earthing transformers. It is used in resonant-earthed MV networks.

Composition
arc suppression coils (fixed and adjustable under load), neutral-forming and earthing transformers, combined devices
Control
electronic controller with an automatic mode
Application
resonant-earthed medium-voltage networks
Manufacture
the company's plant, Neumark, Germany

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Arc suppression coils are available as fixed units and as units adjustable under load. Neutral-forming and earthing transformers are supplied separately, and combined devices are also available. Coil tuning is handled by an electronic controller with an automatic mode. Manufactured at the company's plant in Neumark, Germany.

Technical specifications

Compositionarc suppression coils (fixed and adjustable under load), neutral-forming and earthing transformers, combined devices
Controlelectronic controller with an automatic mode
Applicationresonant-earthed medium-voltage networks
Manufacturethe company's plant, Neumark, Germany

Replacement for

РЗДПОМ-…/6–10, РЗДСОМ, РУОМ, РДМР (arc suppression 6–35 kV); ФМЗО, ТМПС (neutral-forming ZNyn 6–35 kV)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Arc suppression coils and earthing transformers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 50 00 90
HS, 6 digits8504 50
CN (EU)8504 50 00
HTSUS (USA)8504 50 80 00
China customs tariff8504 50 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What networks is the equipment intended for?

Resonant-earthed medium-voltage networks where the capacitive earth-fault current must be compensated.

Are there coils with on-load adjustment?

Yes. Besides fixed coils, coils adjustable under load are produced, with an electronic controller in automatic mode.

Where is this equipment made?

At the company's plant in Neumark, Germany.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides