Dry-type air-core and iron-core reactors 10–800 kV: shunt, current-limiting, filter, smoothing and arm reactors for DC lines
Dry-type air-core and iron-core reactors cover classes from 10 to ±800 kV. They include shunt, current-limiting, filter, neutral, smoothing and arm reactors for AC networks, capacitor banks and DC transmission.
- Shunt 110 kV
- BKGKL-2×40000/110: 115 kV max., 2×73.1 mH, LI 650 kV, losses ≤196 kW
- Current-limiting
- 10–110 kV (XKGKL-10-4000-10: 0.46 mH) and 220–750 kV
- Series / damping
- for capacitor banks of 10–110 kV (CKGKL-12/10-1: 18.33 mH)
- Neutral
- ZJKK-400/15: 66 kV, 15 Ohm, LI 325 kV
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The manufacturer, together with its subsidiary, produces dry-type air-core and iron-core reactors for distribution and trunk networks, capacitor installations and DC converter substations. It built the industry's first dry-type air-core arm reactor of ±800 kV for the Wudongde multi-terminal link, ±800 kV smoothing reactors for the West–East links and filter reactors for the Yazhong–Jiangxi ±800 kV link. It also has China's first installation of 110 kV series air-core reactors for direct load-side compensation.
Air-core reactors have linear inductance, high withstand to surge currents, a small skin effect and low eddy-current losses. They are protected from rain and birds, run quietly and are easy to install. Shunt reactors of 10–110 kV compensate reactive power and limit overvoltages. An example is the BKGKL-2×40000/110 with an inductance of 2×73.1 mH, a maximum voltage of 115 kV, insulation of LI 650 kV and losses up to 196 kW. The winding temperature rise is 55 K and that of the hottest spot, per the manufacturer, is up to 73 K. Such units are bought by grid companies, electrified railways, and metallurgical and petrochemical enterprises.
Current-limiting reactors of 10–110 kV and 220–750 kV are connected in series in a line to bring the short-circuit current down to an allowable level, for example the XKGKL-10-4000-10 of 0.46 mH. Series and damping reactors for capacitor banks of 10–110 kV (CKGKL-12/10-1, 18.33 mH) suppress amplification of higher harmonics and limit inrush currents on energisation. Neutral reactors of 35–66 kV limit the earth-fault current; the ZJKK-400/15 is designed for 66 kV and 15 Ohm with insulation of LI 325 kV. Filter reactors of 8–220 kV work in the filters of DC substations in series with capacitors (LKK-25-342-59.5, 59.5 mH, LI 550 kV).
For DC transmission, smoothing reactors of 20–800 kV are made, connected between the converter and the line. The PKGKL-800-5000-75 is rated ±800 kV, 5000 A, 75 mH, LI 1300 kV, with losses up to 300 kW. Arm reactors of 20–800 kV for voltage-source converter links, such as the QKGKL-800-1472-40 for ±800 kV and 40 mH with insulation of LI 1050 kV, together with the leakage inductance of the transformer form the interface between the converter and the grid and limit short-circuit currents.
Dry-type iron-core reactors for 10 kV are represented by the series CKSC-1200/10-12 (1200 kvar, 1.728 Ohm) and the shunt BKSC-10000/10 (10 Mvar, 10 Ohm). They are compact and light, with radial magnetic cores of reduced eddy-current losses, vacuum-cast windings, low partial discharge, noise of up to 59–60 dB(A) and vibration dampers.
Technical specifications
| Shunt 110 kV | BKGKL-2×40000/110: 115 kV max., 2×73.1 mH, LI 650 kV, losses ≤196 kW |
|---|---|
| Current-limiting | 10–110 kV (XKGKL-10-4000-10: 0.46 mH) and 220–750 kV |
| Series / damping | for capacitor banks of 10–110 kV (CKGKL-12/10-1: 18.33 mH) |
| Neutral | ZJKK-400/15: 66 kV, 15 Ohm, LI 325 kV |
| Filter | 8–220 kV, for filters of DC substations (LKK-25-342-59.5: 59.5 mH, LI 550 kV) |
| Smoothing ±800 kV | PKGKL-800-5000-75: 75 mH, 5000 A, LI 1300 kV, losses ≤300 kW |
| Arm ±800 kV (VSC) | QKGKL-800-1472-40: 40 mH, LI 1050 kV |
| Iron-core 10 kV | CKSC-1200/10-12 (1200 kvar), BKSC-10000/10 (10 Mvar), noise ≤59–60 dB(A) |
Replacement for
РБ, РБА, РБГ, РБДГ, РТСТ, РТОС (dry-type current-limiting 6–35 kV); ФРОС, ФРОМ (filter reactors for filter-compensating units and static var compensators); dry-type 110–800 kV has no direct equivalent
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Dry-type air-core and iron-core reactors 10–800 kV: shunt, current-limiting, filter, smoothing and arm reactors for DC lines. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 50 00 00 |
|---|---|
| HS, 6 digits | 8504 50 |
| CN (EU) | 8504 50 95 |
| HTSUS (USA) | 8504 50 00 00 |
| China customs tariff | 8504 50 00 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
What are the parameters of the ±800 kV smoothing reactor?
The PKGKL-800-5000-75 is rated 5000 A and 75 mH, insulation LI 1300 kV. Losses up to 300 kW.
What is the neutral reactor ZJKK-400/15 for?
It limits the earth-fault current in 35–66 kV networks. Parameters: 66 kV, 15 Ohm, insulation LI 325 kV.
How do iron-core reactors differ from air-core ones?
They are more compact and lighter, with radial magnetic cores and vacuum-cast windings. For 10 kV the CKSC-1200/10-12 rated 1200 kvar and the BKSC-10000/10 rated 10 Mvar are made, with noise of up to 59–60 dB(A).