ASR arc suppression reactors (Petersen coils), continuously adjustable, 6–110 kV

Continuously adjustable ASR arc suppression reactors (Petersen coils) for 6–110 kV networks with ratings of 125–19000 kVA. They compensate the capacitive earth fault current in MV and HV networks and are connected to the neutral of a power or earthing transformer.

Rated network voltage
6–110 kV
Rated power
125–19000 kVA
Frequency
50 Hz
Duty
short-time (KB-2h) or continuous (DB)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The reactor current is adjusted continuously in the range of 10–100 % In, at a network frequency of 50 Hz. The reactors are made for short-time (KB-2h) or continuous (DB) duty and comply with IEC 60076-6. The combined ASRC version joins the reactor and an earthing transformer in one tank, which is convenient for networks without an accessible neutral. The set includes a current indicator DU and a voltage indicator Uo.

Technical specifications

Rated network voltage6–110 kV
Rated power125–19000 kVA
Frequency50 Hz
Dutyshort-time (KB-2h) or continuous (DB)
Current adjustment range10–100 % In, continuous
StandardIEC 60076-6
Versionincluding the combined ASRC reactor with an earthing transformer in a common tank
Accessoriescurrent indicator DU, voltage indicator Uo

Replacement for

РЗДПОМ-…/6–10, РЗДСОМ, РУОМ, РДМР (arc suppression reactors 6–35 kV); for 110 kV there is no direct analogue

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

ASR arc suppression reactors (Petersen coils), continuously adjustable, 6–110 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 50 00 90
HS, 6 digits8504 50
CN (EU)8504 50 00
HTSUS (USA)8504 50 80 00
China customs tariff8504 50 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

For which networks and ratings are the ASR reactors made?

For 6–110 kV networks at 50 Hz, rated power 125–19000 kVA.

In what range is the reactor current adjusted?

Continuously within 10–100 % of rated current.

What is the ASRC version?

A combined unit in which the arc suppression reactor and an earthing transformer are placed in a common tank.