International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TPM / TPM Air monobloc medium voltage ring main unit (RMU) up to 25 kV

TPM and TPM Air are compact indoor ring main units (RMU) for voltages up to 25 kV and a rated current of 630 A. They are used for secondary distribution in urban and industrial networks. The design allows expansion and remote control for Smart Grid.

Rated voltage
up to 25 kV (TPM Air up to 24 kV)
Rated current
630 A
Short-time withstand current
16 kA (3 s) / 20 kA (1 s) / 25 kA (3 s)
Insulation
TPM: SF6 gas; TPM Air: dry air and vacuum chambers, no SF6

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TPM version has SF6 gas insulation and operates at voltages up to 25 kV. TPM Air is insulated with dry air, switching takes place in vacuum chambers, without SF6, and the voltage limit is 24 kV. Short-time withstand current is 16 kA (3 s), 20 kA (1 s) or 25 kA (3 s) depending on the version. The range includes line, transformer and bus-section units, circuit-breaker units and metering units. The devices comply with the standards PN-EN 62271-1, -100, -105, -200.

Technical specifications

Rated voltageup to 25 kV (TPM Air up to 24 kV)
Rated current630 A
Short-time withstand current16 kA (3 s) / 20 kA (1 s) / 25 kA (3 s)
InsulationTPM: SF6 gas; TPM Air: dry air and vacuum chambers, no SF6
Unitsline, transformer, circuit-breaker, bus-section, metering
StandardsPN-EN 62271-1, -100, -105, -200

Request a price and lead time

TPM / TPM Air monobloc medium voltage ring main unit (RMU) up to 25 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
HS, 6 digits8537 20
CN (EU)8537 20 91
HTSUS (USA)8537 20 00 20
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How does TPM differ from TPM Air?

TPM is SF6 gas insulated and works up to 25 kV. TPM Air uses dry air and vacuum chambers without SF6, with voltage up to 24 kV.

What currents can the RMU withstand?

Rated current 630 A. Short-time withstand current 16 kA (3 s), 20 kA (1 s) or 25 kA (3 s).

What types of units are in the series?

Line, transformer, circuit-breaker, bus-section and metering units. The series complies with PN-EN 62271-1, -100, -105, -200.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides