SPREPOWER MV-M6-G, M12, M17 — generator switchgear up to 17.5 kV, up to 7000 A

SPREPOWER MV-M6-G, MV-M12 and MV-M17 are generator switchgear assemblies from the manufacturer for 12, 15 and 17.5 kV, intended for connecting power plant generators. The series are rated for high operating and short-circuit currents, from 5100 to 7000 A and up to 72 kA. All have the loss of service continuity category LSC 2B and a type-tested pressure relief duct.

M6-G
12/15/17.5 kV, 5200 A, 72 kA (peak 193 kA), withdrawable, IAC AFLR up to 72 kA/0.1 s or 63 kA/0.5 s
M12
12/15/17.5 kV, 7000 A, 63 kA (peak 160 kA), on trucks, IAC AFLR up to 63 kA/0.3 s
M17
12/15/17.5 kV, 5100 A, 72 kA (peak 197 kA), trucks with motor drive
Loss of service continuity
LSC 2B

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

MV-M6-G is a compact air-insulated switchgear with withdrawable devices for high currents. The busbar and feeder current is 5200 A, the thermal withstand current 72 kA and the peak current 193 kA. The power-frequency test voltage is 28/36/38 kV and the impulse voltage 75/95/95 kV for 12/15/17.5 kV respectively. Internal arc resistance is IAC AFLR up to 72 kA/0.1 s or 63 kA/0.5 s. The cubicle height is 2400–2550 mm, the width 800–1000 mm (only 1000 mm for 15 and 17.5 kV) and the depth 1600 mm.

MV-M12 has devices on withdrawable trucks and the highest busbar and feeder current in the range, up to 7000 A. The withstand current is 63 kA, the peak current 160 kA, IAC AFLR up to 63 kA/0.3 s. The cubicle dimensions are 3000×1500×2200 mm, and the test voltages are the same as for MV-M6-G. It is chosen for generators whose current exceeds the limits of compact cubicles.

MV-M17 is built on trucks with a motor drive. It is compact at high currents with good access to all components. The current is 5100 A, 72 kA, peak current 197 kA. For 17.5 kV the power-frequency test voltage is up to 50 kV and the impulse voltage up to 110 kV. IAC AFLR is up to 72 kA/0.1 s or 63 kA/0.5 s, and the dimensions are 2900×1200×2300 mm. The motor drive moves the device without manual work at the cubicle. At a width of 1200 mm the MV-M17 cubicle is narrower than MV-M12 with its 1500 mm.

Generator switchgear is equipped with SPRECON protection and automation, including generator protection, the SPRECON-E-C-SYNC synchronizing device and regulators. Before closing the generator circuit breaker, the synchronizing device compares the phase difference, frequency and voltage amplitude of the generator and the network. These belong to one SPRECON platform, so engineering and service of the secondary part are the same. The supply includes design, installation and commissioning. Applications are generator switchgear of hydro, thermal and industrial power plants, auxiliary power of power plants, and connection of high-power generators to a 6–15 kV network.

Technical specifications

M6-G12/15/17.5 kV, 5200 A, 72 kA (peak 193 kA), withdrawable, IAC AFLR up to 72 kA/0.1 s or 63 kA/0.5 s
M1212/15/17.5 kV, 7000 A, 63 kA (peak 160 kA), on trucks, IAC AFLR up to 63 kA/0.3 s
M1712/15/17.5 kV, 5100 A, 72 kA (peak 197 kA), trucks with motor drive
Loss of service continuityLSC 2B
Test voltages28–50 kV (50 Hz), 75–110 kV (impulse)

Request a price and lead time

SPREPOWER MV-M6-G, M12, M17 — generator switchgear up to 17.5 kV, up to 7000 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
HS, 6 digits8537 20
CN (EU)8537 20 91
HTSUS (USA)8537 20 00 00
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which series is rated for 7000 A?

MV-M12 with devices on withdrawable trucks, busbar and feeder current up to 7000 A, withstand current 63 kA, peak current 160 kA.

How resistant is the generator switchgear to internal arc?

MV-M6-G and MV-M17 have IAC AFLR up to 72 kA/0.1 s or 63 kA/0.5 s, MV-M12 up to 63 kA/0.3 s.

Which voltages are the SPREPOWER generator switchgear made for?

All three series are made for 12, 15 and 17.5 kV. They are used for connecting generators to a 6–15 kV network and for auxiliary power of power plants.