CBGS-2 REN — 52 kV, 630 A gas-insulated units for solar plant networks and renewable energy sites

CBGS-2 REN is a range of gas-insulated 52 kV, 630 A units for medium-voltage networks of solar plants and other renewable energy sites. The standard functions D, S and 0 together with a metering unit are assembled into radial and ring schemes of solar plant generating stations.

Rated voltage
52 kV
Power frequency withstand voltage
95 kV
Lightning impulse
250 kV
Rated busbar current
630 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

CBGS-2 REN is built on the 52 kV CBGS-2 range for medium-voltage networks of renewable energy projects, primarily solar photovoltaic plants. A solar plant network connects several generating stations in radial or ring lines. Therefore the standard set consists of function D (transformer protection by circuit breaker), function S (incomer with disconnector), function 0 (side incomer) and a metering unit. These are assembled into the configurations SD, SSD, 0D, 0SD, 00D and others.

The unit has an upper busbar tank of 3 mm stainless steel with a three-position disconnector (closed, open, earthed), a sealed circuit breaker tank, a cable compartment and a low-voltage compartment. The front panel carries a mimic diagram, position indicators, an operation counter, an SF6 pressure gauge, capacitive voltage indicators on each phase and a mechanical emergency trip button. The disconnector complies with IEC 62271-102 and makes onto a short circuit of 20/25 kA through the circuit breaker. Operation is manual. The lever cannot be removed until the operation is complete, and the circuit breaker will not close until the lever has been taken off.

The 52 kV circuit breaker is made for a rated current of 630 or 200 A. The rated breaking current is 20–25 kA, the making current is 50–63 kA (peak), the capacitive load breaking current is 220 A, and the operating sequence is O–0.3 s–CO–3 min–CO. Breaking time is 35–43 ms and making time 55–65 ms. The transformer unit is equipped with a motor operating mechanism for the circuit breaker, a double trip coil, 110/125 V DC control circuits and, to order, an Easergy P1 protection relay.

Current transformers are toroidal or flange-mounted for commercial metering, and voltage transformers are flange-mounted on the gas tank, with cast insulation and an external earthed screen. One cable is connected per phase. The units comply with IEC 62271-1, IEC 62271-100, IEC 62271-102 and IEC 62271-200 and work from −5 to +40 °C at altitudes up to 1000 m; for other conditions the design is agreed with the manufacturer. Internal arc resistance per the catalogue is 20–25 kA for 0.5 s. The marking on the units shows the manufacturer and the country, Spain.

Technical specifications

Rated voltage52 kV
Power frequency withstand voltage95 kV
Lightning impulse250 kV
Rated busbar current630 A
Rated feeder current630 / 200 A
Rated breaking current20 / 25 kA
Short-circuit making current50 / 63 kA (peak)
Capacitive load breaking current220 A
Circuit breaker operating sequenceO–0.3 s–CO–3 min–CO
SF6 overpressure at 20 °C0.40 bar
Degree of protectionIP65 (HV compartments); IP3X (LV compartments)
Control voltage110 / 125 V DC
Ambient temperature−5 to +40 °C
Installation altitudeup to 1000 m

Request a price and lead time

CBGS-2 REN — 52 kV, 630 A gas-insulated units for solar plant networks and renewable energy sites. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
HS, 6 digits8537 20
CN (EU)8537 20 91
HTSUS (USA)8537 20 00 20
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which functional units make up CBGS-2 REN?

Function D for transformer protection by circuit breaker, S for an incomer with disconnector, 0 for a side incomer, and a metering unit. They are assembled into the schemes SD, SSD, 0D, 0SD and 00D.

What short-circuit currents does the unit withstand?

The rated breaking current is 20 or 25 kA, the making current is 50 or 63 kA (peak), and the short-time withstand current is 20–25 kA for 3 s.

What is the control circuit voltage of CBGS-2 REN?

The circuit breaker control circuits are rated 110 or 125 V DC. The transformer unit has a motor operating mechanism and a double trip coil.