Explosion-protected equipment (Ex)
Explosion-protected junction boxes, control stations, luminaires, plugs and sockets, panels and switches, intrinsic safety barriers and purge systems for hazardous areas in oil and gas, chemical and mining plants. 139 items.

Explosion-protected equipment (Ex)Ex d and Ex tb flameproof boxes, aluminium or stainless steel, IP66

Explosion-protected equipment (Ex)Ex e, Ex ia, Ex tb boxes in GRP or stainless steel, IP66, NEMA Type 4X

Explosion-protected equipment (Ex)Ex e local control units in polyamide or AISI 316L steel, −40 … 55 °C

Explosion-protected equipment (Ex)Ex d flameproof control stations, aluminium or stainless steel, IP66

Explosion-protected equipment (Ex)Ex e control stations in GRP or AISI 316L stainless steel, −40 … 55 °C

Explosion-protected equipment (Ex)Enviro-Line pressurisation kit for enclosures up to 250 ft³ (7.2 m³)

Explosion-protected equipment (Ex)Ex pyb purge system, 6500 series, enclosures up to 12.7 m³ (450 ft³)

Explosion-protected equipment (Ex)Type X purge system, 6000 series, enclosures up to 450 ft³ (12.7 m³)

Explosion-protected equipment (Ex)Ex pzc purge system for enclosures up to 12.7 m³ (450 ft³), IP66

Explosion-protected equipment (Ex)Tubular LED light fitting, Ex d, 13 ... 48 W, from 338 lm, IP66/IP68, IK10

Explosion-protected equipment (Ex)LED floodlight, 100, 160 and 225 W, 110 ... 277 V AC, stainless steel, IP66, IK10

Explosion-protected equipment (Ex)Ex nR LED floodlight, 100, 160 and 225 W, 110 ... 277 V AC, IP66, IK10, -60 ... +60 °C

Explosion-protected equipment (Ex)Ex ec LED floodlight, 100, 160 and 225 W, 110 ... 277 V AC, IP66, IK10, -60 ... +60 °C

Explosion-protected equipment (Ex)C-LUX emergency LED luminaire, up to 775 lm, 1.5/3 h, IP66/IP67, Zones 1, 2, 21, 22

Explosion-protected equipment (Ex)EXLUX linear LED luminaire, up to 7920 lm, IP66/IP67, mounting height up to 10 m

Explosion-protected equipment (Ex)EXLUX emergency LED luminaire, 25 and 45 W, 2910 and 5810 lm, 1.5 ... 3.0 h

Explosion-protected equipment (Ex)EXLUX linear LED luminaire, 18 ... 42 W, up to 5100 lm, IP66/IP67

Explosion-protected equipment (Ex)EXLUX emergency LED luminaire, 25 and 45 W, 2910 and 5810 lm, 90 or 180 minutes

Explosion-protected equipment (Ex)EXLUX emergency LED luminaire, sizes 2 and 4, 25 W, 7 Ah NiCd battery, IK10

Explosion-protected equipment (Ex)Visual signalling device, LED or 5 J xenon, Ex d/Ex e chamber, IP66/67

Explosion-protected equipment (Ex)MiniCON NEC/CE Code plug connectors, 500 V, 8 A, seven poles, M20/M32
Explosion-protected equipment (Ex)MiniCON coupling, 500 V, 16 A, 7 P + PE / 8 P, IP66/IP67, Zones 1, 2, 21, 22
Explosion-protected equipment (Ex)MiniCON plug, 500 V, 16 A, 7 P + PE / 8 P, IP66/IP67, Zones 1, 2, 21, 22
Explosion-protected equipment (Ex)MiniCON flange socket for Ex e enclosure, 500 V, 16 A, IP66/IP67
Explosion-protected equipment (Ex)MiniCON device plug for Ex e enclosure, 500 V, 16 A, M32 x 1.5

Explosion-protected equipment (Ex)TOUGHLUX linear LED luminaire, 2890 and 5770 lm, IP66/IP67, IK10

Explosion-protected equipment (Ex)TOUGHLUX linear LED luminaire, 19 and 35 W, 2800 and 5600 lm, IP66/IP67, IK10

Explosion-protected equipment (Ex)Audible signalling device, up to 120 dB(A) at 1 m, 4 tone channels, 64 tones, IP66

Explosion-protected equipment (Ex)Audible and visual signalling device, up to 120 dB(A) at 1 m, LED or 5 J, Ex d/Ex e

Explosion-protected equipment (Ex)Explosion-protected lighting switch, 2 poles, 690 V AC, 16 A, IP66

Explosion-protected equipment (Ex)Motor protection breakers for Ex e / Ex d motors, 0.16–32 A, 3-pole, Ex db eb IIC T4 Gb, IP66

Explosion-protected equipment (Ex)Ex safety switch, 250 A, 690 V / 500 V AC, AC-3 and AC-23, IP65

Explosion-protected equipment (Ex)Ex safety switches, 10–180 A, up to 690 V AC, AC-3, 3-pole, 6-pole and 3-pole + N

Explosion-protected equipment (Ex)Safety switches, stainless steel 1.4404, 16–125 A, 690 V AC, AC-3, IP66
Explosion-protected equipment (Ex)16 A plug, 3-, 4- and 5-pole, IP66, Zones 2 and 22, silicone-free, cable 8 - 18 mm
Explosion-protected equipment (Ex)32 A plug, 3P+PE or 3P+N+PE, IP66, Zones 2 and 22, silicone-free, cable 13 - 25 mm

Explosion-protected equipment (Ex)63 A plug, 3P+PE or 3P+N+PE, IP66, Zones 2 and 22, silicone-free, cable 24 - 36 mm

Explosion-protected equipment (Ex)20 A plug, 3-, 4- and 5-pole, NEC 505, cable 8 - 19.70 mm, protective cap

Explosion-protected equipment (Ex)32 A plug, 3P+PE or 3P+N+PE, Zones 1, 2, 21, 22, cable 13 - 25 mm

Explosion-protected equipment (Ex)63 A plug, 3P+PE or 3P+N+PE, Zone 1/21, floating pins

Explosion-protected equipment (Ex)125 A plug, 3P+PE or 3P+N+PE, Zone 1/21, cable 30 - 45 mm

Explosion-protected equipment (Ex)SolConeX 16 A plug, 3-, 4- and 5-pole, floating pins, polyamide

Explosion-protected equipment (Ex)Plug 16 A, extra-low voltage, 2 or 3 poles, floating pins, IP66

Explosion-protected equipment (Ex)Loudspeaker 25 W or 15 W, 8 Ω or 20 Ω, IP66/IP67, -50 °C to +60 °C

Explosion-protected equipment (Ex)Explosion-protected high-frequency motion sensor, 1 to 8 m, 1000 W, IP66

Explosion-protected equipment (Ex)Ex e / Ex i junction box, 5 x 4 mm², IP66, glass-fibre polyester

Explosion-protected equipment (Ex)Ex e / Ex i junction box, 4, 5, 8 terminals, fuses to 6.3 A, IP66

Explosion-protected equipment (Ex)LED obstruction light, 10 cd and 32 cd, 24 V DC or 100 ... 254 V AC

Explosion-protected equipment (Ex)Safety temperature monitor or limiter, up to 25 A, 230 V AC, IP66, Ex db eb IIC T6 Gb

Explosion-protected equipment (Ex)Circuit protection assembly 10 A ... 125 A, 1.4404 stainless steel, IP66

Explosion-protected equipment (Ex)Cable reel Ex db eb IIC T6, 16 and 32 A, line 20 - 30 m

Explosion-protected equipment (Ex)Ex e cable end box, terminals to 185 mm², 690 V, up to 400 A

Explosion-protected equipment (Ex)Pipe mounted safety temperature monitor, 230 V AC, 16 A (T6), IP66/67, Ex db eb IIC T6

Explosion-protected equipment (Ex)Wall mounted safety temperature monitor, 230 V AC, 16 A (T6), IP66/67, Ex db eb IIC T6

Explosion-protected equipment (Ex)Ex LED hand lamp 1 W, 30 lm, 35 m range, IP68, 2 x AAA

Explosion-protected equipment (Ex)Ex e / Ex i aluminium terminal box, IP66, 58 x 64 x 34 - 600 x 310 x 180 mm

Explosion-protected equipment (Ex)Ex e NEC/IEC terminal box, up to 690 V IEC / 600 V NEC, IP66

Explosion-protected equipment (Ex)Ex i NEC/IEC terminal box, 60 V, IP66, up to 51 terminals

Explosion-protected equipment (Ex)Ex e stainless steel terminal box, IP66, 690 V IEC / 600 V UL

Explosion-protected equipment (Ex)Ex i stainless steel terminal box, IP66, M8, up to 27 terminals

Explosion-protected equipment (Ex)Ex e terminal box, spring-lever terminals 0.14-4 mm², 440 V

Explosion-protected equipment (Ex)Ex e / Ex i terminal box, up to 690 V, up to 36 conductors, IP66

Explosion-protected equipment (Ex)Ex e stainless steel 1.4404 terminal box, IP66, 14 sizes

Explosion-protected equipment (Ex)Stainless steel 1.4301 / 1.4404 terminal box, IP66, 130° hinged cover

Explosion-protected equipment (Ex)Panel mounting buttons and switches, Ex e chamber, spring clamp terminals, 6 A, ATEX, IECEx, NEC® 500, 505, 506

Explosion-protected equipment (Ex)Explosion-protected panel mounting buttons and switches, spring clamp terminals, 500 V AC, 6 A, Ex db eb IIC T6 Gb

Explosion-protected equipment (Ex)Panel mounting buttons and switches with plug-in connection and 6 m cable, 500 V AC, 6 A, IP65/IP66

Explosion-protected equipment (Ex)Panel mounting buttons and switches with 6 m cable, 500 V AC, 6 A, Ex db eb IIC T6 Gb, NEC® 500, 505, 506

Explosion-protected equipment (Ex)Compact coupling 16 A, extra-low voltage up to 50 V, 2 or 3 poles

Explosion-protected equipment (Ex)Compact wall-mounting socket 16 A, up to 277 V, mechanical locking

Explosion-protected equipment (Ex)Wall-mounting socket 16 A for extra-low voltage up to 50 V, 2 or 3 poles

Explosion-protected equipment (Ex)SolConeX compact coupling 16 A, 3-pole, up to 277 V, IP66

Explosion-protected equipment (Ex)Ex LED luminaire C-LUX, 100-240 V AC, IP66/IP67, IK08

Explosion-protected equipment (Ex)Compact flange socket 16 A, 3-pole, AC-3, IP66, zones 1, 2, 21, 22

Explosion-protected equipment (Ex)ExSys Cool air conditioner, 4 kW to EN 14511, setpoint 18 °C ... 35 °C

Explosion-protected equipment (Ex)Explosion-protected remote control panel for helideck lights, 5 circuits, IP66

Explosion-protected equipment (Ex)Disconnect and transfer switches, 15–150 A, up to 600 V AC / 240 V DC, GRP, Class I Div. 2 / AEx Zone 2

Explosion-protected equipment (Ex)Disconnect and transfer switches, stainless steel 1.4404, 15–150 A, up to 600 V AC / 240 V DC, IP66

Explosion-protected equipment (Ex)Load disconnect and manual transfer switches, 15–150 A, up to 600 V AC / 240 V DC, IP66

Explosion-protected equipment (Ex)Switches in a stainless steel 1.4404 enclosure, 15–150 A, up to 600 V AC / 240 V DC

Explosion-protected equipment (Ex)Ex load disconnect switches, 10–80 A, AC-3 / AC-23 / DC-23, Zones 1/2/21/22

Explosion-protected equipment (Ex)Ex LED head torch 5 W, 120 lm, 150 m range, 4 x AAA

Explosion-protected equipment (Ex)16 A wall-mounting socket, 2P+PE to 3P+N+PE, IP66, Zones 2 and 22, silicone-free

Explosion-protected equipment (Ex)32 A wall-mounting socket, 3P+PE, IP66, Zones 2 and 22, silicone-free

Explosion-protected equipment (Ex)20 A wall-mounting socket, 2-, 3- and 4-pole, Zones 1, 2, 21, 22, NEC 505, NPT 3/4″

Explosion-protected equipment (Ex)32 A wall-mounting socket, 3P+PE or 3P+N+PE, IP66, Zones 1, 2, 21, 22

Explosion-protected equipment (Ex)63 A wall-mounting socket, 3P+PE or 3P+N+PE, IP66, Zones 1, 2, 21, 22

Explosion-protected equipment (Ex)60 A wall-mounting socket, 3-pole and 4-pole, IP66, Class I Div. 2, Zone 1/21

Explosion-protected equipment (Ex)125 A wall-mounting socket, 3P+PE or 3P+N+PE, IP66, Zone 1/21

Explosion-protected equipment (Ex)100 A wall-mounting socket, 3-pole and 4-pole, IP66, Class I Div. 2, Zone 1/21

Explosion-protected equipment (Ex)Clean room socket panel, 20 or 30 A, Zone 1, 2, 21, 22, stainless steel 316L

Explosion-protected equipment (Ex)SolConeX 16 A wall-mounting socket, 3-, 4- and 5-pole, AC-3, IP66

Explosion-protected equipment (Ex)Clean room socket distributor, 16 and 32 A, Zone 1, 2, 21, 22, AISI 316L

Explosion-protected equipment (Ex)Ex LED inspection light 1396 lm, 12 V / 24-48 V / 110-240 V, IP66/IP67

Explosion-protected equipment (Ex)Ex portable LED searchlight 40000 cd, 200.00 m, IP66, 6 V 4 Ah battery

Explosion-protected equipment (Ex)Portable LED searchlight 24000 cd, 156.00 m, IP66, 6 V 4 Ah battery

Explosion-protected equipment (Ex)7.5 kW frequency converter drive, up to 55 °C without derating

Explosion-protected equipment (Ex)32 A coupler socket with switch, 3P+PE or 3P+N+PE, Zones 1, 2, 21, 22

Explosion-protected equipment (Ex)SolConeX 16 A coupler socket with switch, AC-3, stainless steel frame

Explosion-protected equipment (Ex)EXpressure Ex d empty cabinet, stainless steel, 980 dm³, IP66, 11 kV, 1250 A

Explosion-protected equipment (Ex)Explosion-protected FRP control station, 550 V AC, 10 A, IP66

Explosion-protected equipment (Ex)Explosion-protected control station in 316L steel, 6 A, IP66, -50 °C to +60 °C

Explosion-protected equipment (Ex)Explosion-protected control station, stainless steel 1.4404 (316L), 6 A, IP66, -50 °C to +60 °C

Explosion-protected equipment (Ex)Panel-mount potentiometer, 100 Ω to 1 MΩ, 2 W, 400 V, IP66 or IP20

Explosion-protected equipment (Ex)Ex LED floodlight 20-80 W, 110-277 V, -55 to +70 °C

Explosion-protected equipment (Ex)63 A maintenance socket, 3P+N+PE, 200/346 ... 240/415 V AC, indicator lamps

Explosion-protected equipment (Ex)Explosion-protected 30 A wall socket, 50 / 60 Hz, Zone 1, 2, 21, 22

Explosion-protected equipment (Ex)30 A flange socket, 50 / 60 Hz, for 'eb' or 'tb' enclosures

Explosion-protected equipment (Ex)Pipe mounted heat tracing junction box in 316L steel, Ex eb IIC T5 Gb, IP66/67

Explosion-protected equipment (Ex)Wall mounted heat tracing junction box in 316L steel, Ex eb IIC T5 Gb, IP66/67

Explosion-protected equipment (Ex)Pipe mounted heat tracing junction box in 316L steel, 4 mm², Ex eb IIC T5 Gb, IP66/67

Explosion-protected equipment (Ex)Wall mounted heat tracing junction box in 316L steel, 4 mm², Ex eb IIC T5 Gb, IP66/67

Explosion-protected equipment (Ex)G145 control and distribution boxes, up to 1100 V AC/DC, up to 630 A, IP66

Explosion-protected equipment (Ex)Ex LED hand lamp 5 W, 120 lm, 150 m range, IP68, 4 x AA

Explosion-protected equipment (Ex)LED illuminated pushbutton for panel mounting, Ex db mb IIC T6 Gb, 6 A, 6 m cable, 30 mm hole, NEC® 500, 505, 506

Explosion-protected equipment (Ex)LED illuminated pushbutton for panel mounting, Ex e and Ex i, 6 A, 270 V AC, IP65, 6 m cable, 30 mm hole

Explosion-protected equipment (Ex)LED inspection light 1396 lm, 24-48 V / 110-240 V, IP66/IP67

Explosion-protected equipment (Ex)Panel-mount LED indicator, Ex d e / Ex i, 12–254 V or 10.8–28 V, UL versions

Explosion-protected equipment (Ex)Panel-mount LED indicator, Ex d e / Ex i, 12–254 V or 10.8–28 V, IP66 front

Explosion-protected equipment (Ex)Signal lamp 5 J or LED, IP66, -40 °C to +40 °C, six lens colours

Explosion-protected equipment (Ex)6036/3 LED tubular light fitting, 100…277 V, up to 6040 lm, IP66/IP67/IP68, -55…+70 °C

Explosion-protected equipment (Ex)Series 8040 control device system, three sizes, GRP enclosure, zones 1, 2, 21, 22

Explosion-protected equipment (Ex)8146/1 Ex e polyester terminal boxes, up to 690 V, IP66, terminal blocks up to 300 mm²

Explosion-protected equipment (Ex)8146/2 Ex i polyester terminal boxes, 60 V, IP66, up to 196 terminals of 2.5 mm²

Explosion-protected equipment (Ex)Series 8146 Ex e polyester control boxes, eight basic sizes, 112.5 x 91 up to 681.500 x 340.500 mm

Explosion-protected equipment (Ex)8150/1 stainless steel Ex e terminal boxes, 690 V, IP66, up to 114 terminals of 2.5 mm²

Explosion-protected equipment (Ex)8150/2 stainless steel Ex i terminal boxes, 60 V, IP66, up to 52 terminals of 2.5 mm²

Explosion-protected equipment (Ex)8150/5 stainless steel Ex e control boxes, IP66, up to 1000 x 1200 x 300 mm

Explosion-protected equipment (Ex)Motor control units, Ex d / Ex e: DOL, star-delta, reversing, 400 V, IP65

Explosion-protected equipment (Ex)CUBEx Ex d motor control units: DOL, star-delta, reversing, 400 V, IP66

Explosion-protected equipment (Ex)20 A flange socket, 2-, 3- and 4-pole, Zones 1, 2, 21, 22, enclosure eb or tb

Explosion-protected equipment (Ex)32 A flange socket, 3P+PE or 3P+N+PE, Zones 1, 2, 21, 22

Explosion-protected equipment (Ex)16 A flange socket, 2 or 3 poles, up to 50 V, IP66, Zones 1, 2, 21, 22

Explosion-protected equipment (Ex)SolConeX 16 A flange socket with load disconnect switch, AC-3

Explosion-protected equipment (Ex)Explosion-protected 30 A plug, 50 / 60 Hz, cable 13 - 25 mm

Explosion-protected equipment (Ex)Explosion-protected 60 A plug, IP66, -30 to +40 °C

Explosion-protected equipment (Ex)Explosion-protected 100 A plug, IP66, -30 to +45 °C

Explosion-protected equipment (Ex)Lighting and heating circuit boards, Ex db eb IIC T4/T6 Gb, 230–400 V, 32–80 A, IP66

Explosion-protected equipment (Ex)CUBEx lighting and heating boards, Ex d, aluminium enclosure, 230–400 V, 100 A, IP65
