ExSys Cool series 8701 air conditioner for hazardous areas, 4 kW
The ExSys Cool 8701 air conditioner delivers 4 kW cooling capacity to EN 14511 (L35/L35) and holds a full equipment certificate for Zone 1. A thermal expansion valve adapts the cooling output automatically, with a setpoint range of 18 °C to 35 °C. Versions: Zone 1/Zone 1, Zone 1/Ex p and Zone 1/Non-Ex.
- Series
- 8701
- Cooling capacity to EN 14511 (L35/L35)
- 4 kW
- Temperature setpoint range
- 18 °C ... 35 °C
- Ambient temperature
- -40 °C ... 55 °C (depends on refrigerant)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
ExSys Cool 8701 cools enclosures and rooms in hazardous environments. Its cooling capacity is 4 kW according to EN 14511 (L35/L35). A thermal expansion valve adapts the cooling capacity automatically to changing conditions, so the inside temperature stays constant. The target value can be set anywhere from 18 °C to 35 °C.
The unit is certified as equipment (IECEx, ATEX), so it can be used simply in Ex p and Ex e solutions. A full equipment certificate covers use in Zone 1. The ambient temperature range of -40 °C to 55 °C depends on the refrigerant selected.
The selection table lists three product variants: Zone 1/Zone 1, Zone 1/Ex p and Zone 1/Non-Ex. Each comes with a rated operational current of 7.5 A (total power consumption 1.7 kW) or 9 A (2.1 kW). In the Zone 1/Ex p and Zone 1/Non-Ex variants the ambient temperature is -20 °C to +50 °C for 7.5 A and -40 °C to +50 °C for 9 A, and the weight is 210 kg. An Ex-certified evaporator appears as a separate column of the selection table.
The balanced design allows direct surface mounting without additional support. The packaged type is plug and play and needs no configuration. A split type is available where fire rating or limited space calls for it. Besides the predefined standard configurations, the manufacturer supplies customer-specific solutions to meet HVAC requirements.
Technical specifications
| Series | 8701 |
|---|---|
| Cooling capacity to EN 14511 (L35/L35) | 4 kW |
| Temperature setpoint range | 18 °C ... 35 °C |
| Ambient temperature | -40 °C ... 55 °C (depends on refrigerant) |
| Rated operational current | 7.5 A / 9 A |
| Total power consumption | 1.7 kW / 2.1 kW |
| Weight | 210 kg |
| Variants | Zone 1/Zone 1, Zone 1/Ex p, Zone 1/Non-Ex |
| Certificates | IECEx, ATEX |
| Mounting | direct surface mounting without additional support |
Part numbers
Show all part numbers (6)
8701/01-1010-0200-04, 8701/01-1011-0200-04, 8701/01-1110-0200-04, 8701/01-1111-0200-04, 8701/01-1210-0200-04, 8701/01-1211-0200-04
How it compares with similar models
| Parameter | ExSys Cool series 8701 air conditioner for hazardous areas, 4 kW | SolConeX series 8573/12 plugs, 16 A, for extra-low voltage, 2- and 3-pole | SolConeX series 8573/14 compact couplings, 16 A, for extra-low voltage up to 50 V | Wall-mounted socket distributors for clean rooms, Series 8150/5-V88-3xxxx (IEC) |
|---|---|---|---|---|
| Ambient temperature | -40 °C ... 55 °C (depends on refrigerant) | -50 °C ... +60 °C | -50 °C ... +40 °C | -50 ... +40 °C |
| Weight | 210 kg | 300 g | 300 g | — |
| Certificates | IECEx, ATEX | China (CQST) | China (CQST), ATEX (PTB), IECEx (PTB) | ATEX (PTB), IECEx (PTB), FM (Canada), PESO (India) |
Request a price and lead time
ExSys Cool series 8701 air conditioner for hazardous areas, 4 kW. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which variants does series 8701 include?
Zone 1/Zone 1, Zone 1/Ex p and Zone 1/Non-Ex. Each variant is offered with a rated operational current of 7.5 A or 9 A.
What are the cooling capacity and setpoint range?
Cooling capacity is 4 kW to EN 14511 (L35/L35), and the temperature setpoint range is 18 °C to 35 °C.
How is the air conditioner mounted?
Directly on a surface without additional support. The packaged type needs no configuration, and a split type exists for limited space.
Similar equipment from other manufacturers