International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Series 8150 stainless steel 1.4404 (316L) control stations, explosion-protected, IP66

Series 8150 control stations have a brush finished enclosure in stainless steel 1.4404 (AISI 316L) with a screw-on cover. They are certified to NEC®, CE Code, ATEX and IECEx, with IP66 protection from -50 °C to +60 °C.

Enclosure material
Stainless steel 1.4404 (AISI 316L), brush finished
Cover
Screw-on, captive M6 stainless steel screws
Seal
Silicone, foamed
Degree of protection IP
IP66

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8150 control stations are made of brush finished stainless steel 1.4404 (AISI 316L) and carry explosion-protected components. The steel resists corrosion well. The cover is screw-on, held by captive M6 stainless steel screws. The stations are certified four ways, to NEC®, CE Code, ATEX and IECEx.

High-quality sealing materials cover an extended temperature range of -50 °C to +60 °C, and a protection channel round the edge keeps water out. The seal is foamed silicone. The cable entry is a CMP-737D M25-NPT 3/4” metal adaptor, and the version has no flange.

Elements include pushbuttons, illuminated pushbuttons, control switches and LEDs. Examples are the red EM-STOP mushroom stay-put button 55 and a STOP-RUN-START large handle (2 × 45°). Stations with other entries, contact options and additional certifications are made on request.

Rated operational voltage AC is 0 to 550 V, or 600 V to UL. Rated operational current is 6 A, or 10 A to UL. Connection cross-section is up to 2.5 mm². Protection is IP66 and enclosure type is 3, 4, 4X. The listed size has a width of 116.500 mm, a height of 176.500 mm and a depth of 91 mm.

Explosion protection is Ex db eb IIC T6 Gb and Ex tb IIIC 80 °C Db, for Zone 1, 2, 21, 22. Class I, Div. 2 covers Groups A, B, C, D, and Class II, III, Div. 2 covers Groups F, G. Standards are NEC® 500, 505, 506, CE Code Section 18, IEC 60079-0, IEC 60079-1 and IEC 60079-31. Certificates are ATEX (PTB), IECEx (PTB), USA (UL) and Canada (UL).

Technical specifications

Enclosure materialStainless steel 1.4404 (AISI 316L), brush finished
CoverScrew-on, captive M6 stainless steel screws
SealSilicone, foamed
Degree of protection IPIP66
Enclosure type (UL50 & UL50E)3, 4, 4X
Rated operational voltage AC0 ... 550 V; UL 600 V
Rated operational current6 A; UL 10 A
Ambient temperature-50 °C ... +60 °C
Connection cross-section max.2.5 mm²
EntryCMP-737D M25-NPT 3/4” metal adaptor
Flange and platesWithout flange
Explosion protectionEx db eb IIC T6 Gb; Ex tb IIIC 80 °C Db
StandardsNEC® 500, 505, 506; CE Code Section 18; IEC 60079-0, 60079-1, 60079-31

Part numbers

Show all part numbers (2)

8150/5-0176-0116-091-3311-C2425 (285432), 8150/5-0176-0116-091-3311-C2437 (285444)

How it compares with similar models

ParameterSeries 8150 stainless steel 1.4404 (316L) control stations, explosion-protected, IP66Series 8150/5-V40 NEC® / CE Code control stations in 316L stainless steel, IP66Series 8040 NEC® / CE Code explosion-protected control stations, IP66TEF4500901 local control panel for IMT helideck lights, Ex db eb IIC T4 Gb, IP66
Enclosure materialStainless steel 1.4404 (AISI 316L), brush finishedStainless steel 1.4404 (AISI 316L)Polyester resin, glass fibre reinforced (FRP)Stainless steel 1.4404 (AISI 316L), brush finished
Rated operational current6 A; UL 10 A6 A10 A3 A
Ambient temperature-50 °C ... +60 °C-50 °C ... +60 °C-60 °C ... 40 °C (-76 °F ... +104 °F)-20 °C ... +45 °C
Explosion protectionEx db eb IIC T6 Gb; Ex tb IIIC 80 °C DbEx db eb IIC T6 Gb; Ex tb IIIC 80 °C DbEx db eb IIC T6 Gb; Ex tb IIIC 80 °C Db; Class I, Zone 1, AEx db eb IIC T6E II 2 G Ex db eb IIC T4 Gb; Zone 1, Zone 2

Request a price and lead time

Series 8150 stainless steel 1.4404 (316L) control stations, explosion-protected, IP66. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which certificates do the stainless steel Series 8150 stations hold?

NEC®, CE Code, ATEX and IECEx, with certificates ATEX (PTB), IECEx (PTB), USA (UL) and Canada (UL).

What are the temperature range and protection degree?

-50 °C to +60 °C, IP66, enclosure type 3, 4, 4X.

How is the cover fixed and what is the cable entry?

The cover is screw-on, held by captive M6 stainless steel screws. The entry is a CMP-737D M25-NPT 3/4” metal adaptor.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH