NEC/IEC Series 8150 Ex e Terminal Boxes, Stainless Steel 1.4404, IP66, 690 V
Series 8150 Ex e terminal boxes are made of brush-finished stainless steel 1.4404 (AISI 316L). IP66, external M8 earth connection, 600 V (UL) and 690 V (IEC), ambient range -50 °C to +40 °C.
- Type of protection
- Ex e
- Enclosure material
- Stainless steel 1.4404 (AISI 316L), brush finished
- Degree of protection IP
- IP66
- Rated operational voltage AC UL
- 600 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Series 8150 Ex e terminal boxes are made of brush finished stainless steel (1.4301, ANSI 304 or 1.4404, ANSI 316L) and stand up well to harsh surroundings. A circumferential protection channel on the cover opening and a silicone seal suited to the most extreme temperature ranges make the enclosure usable worldwide.
Protection is IP66, with an M8 external earth connection. The cover is screw-on, with other alternatives on request, and the product text also mentions a hinged cover with cam locks. Fittings can be configured individually, and optional accessories are available.
Rated operational voltage is 600 V AC to UL and 690 V AC to IEC. Ambient temperature runs from -50 °C to +40 °C. The enclosure is stainless steel 1.4404 (AISI 316L). Sizes are 7 x 7 x 3.6 inch and 9.3 x 7 x 3.6 inch, and the weight is 17.64 lb.
Class I Div. 2 and Class I Zone 1 are stated. NEC 500, 505, 506, CE Code Section 18 and IEC 60529 are referenced, and certificates are cULus, IECEx, ATEX, NEPSI and ITRI.
The maximum number of terminals is 9 or 13, on rails of 35 x 133 mm or 35 x 189 mm, with 10 mm² / AWG 8 terminals. Example types are 8150/1-0176-0176-091-3311 and 8150/1-0236-0176-091-3311.
Technical specifications
| Type of protection | Ex e |
|---|---|
| Enclosure material | Stainless steel 1.4404 (AISI 316L), brush finished |
| Degree of protection IP | IP66 |
| Rated operational voltage AC UL | 600 V |
| Rated operational voltage AC IEC | 690 V |
| Min. ambient temperature | -50 °C |
| Max. ambient temperature | +40 °C |
| External earth connection | M8 |
| Dimensions | 7 x 7 x 3.6 inch; 9.3 x 7 x 3.6 inch |
| Max. no. of terminals | 9; 13 |
| Terminal rail | 35 x 133 mm; 35 x 189 mm |
| Application | Class I Div. 2; Class I Zone 1 |
| Standards | NEC 500; NEC 505; NEC 506; CE Code Section 18; IEC 60529 |
| Certificates | cULus, IECEx, ATEX, NEPSI, ITRI |
| Weight | 17.64 lb |
Part numbers
Show all part numbers (2)
278810, 278811
How it compares with similar models
| Parameter | NEC/IEC Series 8150 Ex e Terminal Boxes, Stainless Steel 1.4404, IP66, 690 V | NEC/IEC Series 8150 Ex i Terminal Boxes, Stainless Steel 1.4404, IP66, M8 Earth | NEC/IEC Series 8146/1 Ex e Terminal Boxes, Polyester Resin, 690 V, IP66 | NEC/IEC Series 8146/2 Ex i Terminal Boxes, Ex ia ib IIC T6 Gb, 60 V, IP66 |
|---|---|---|---|---|
| Type of protection | Ex e | Ex i | Ex e | Ex i |
| Enclosure material | Stainless steel 1.4404 (AISI 316L), brush finished | Stainless steel 1.4404 (ANSI 316L), brush finished | Polyester resin, glass fibre reinforced | Polyester resin, glass fibre reinforced |
| Rated operational voltage AC IEC | 690 V | — | 690 V | 60 V |
| Max. no. of terminals | 9; 13 | 19; 27 | 10 ... 26 | 19; 27; 49; 51 |
| Terminal rail | 35 x 133 mm; 35 x 189 mm | 35 x 133 mm; 35 x 189 mm | — | 35 x 133 mm; 35 x 189 mm; 35 x 301 mm |
| Standards | NEC 500; NEC 505; NEC 506; CE Code Section 18; IEC 60529 | NEC 500; NEC 505; NEC 506; CEC Section 18; IEC 60529 | NEC 500; NEC 505; NEC 506; CEC Section 18; IEC/EN 60529 | NEC 500; NEC 505; NEC 506; CEC Section 18; IEC/EN 60529 |
Request a price and lead time
NEC/IEC Series 8150 Ex e Terminal Boxes, Stainless Steel 1.4404, IP66, 690 V. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What material are the 8150 boxes made of?
Brush-finished stainless steel 1.4404 (AISI 316L), and the product text also names 1.4301 (ANSI 304).
What protection rating and earth connection apply?
IP66 with an M8 external earth connection.
What are the rated voltage and temperature range?
600 V (UL) and 690 V (IEC), with ambient temperature from -50 °C to +40 °C.