International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

NEC/IEC Series 8146/2 Ex i Terminal Boxes, Ex ia ib IIC T6 Gb, 60 V, IP66

Series 8146/2 Ex i terminal boxes to NEC/IEC are made of glass-fibre-reinforced polyester resin with IP66 protection. Marked Ex ia ib IIC T6 Gb and Ex tb IIIC T80 °C Db, rated 60 V, -50 °C to +75 °C.

Type of protection
Ex i
Enclosure material
Polyester resin, glass fibre reinforced
Degree of protection (IP)
IP66
Rated operational voltage AC IEC
60 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8146 terminal boxes are made of glass fibre reinforced polyester resin and suit harsh operating conditions. Eight basic sizes in various heights are available. On request the boxes are equipped with terminal blocks up to 300 mm², and a flange can be fitted on several enclosure sides.

The Ex i version has IP66 protection and a cover with captive screws. Equipping follows the customer specification. Terminals are 2.5 mm² (AWG 14), and the selection table lists a maximum of 19, 27, 49 and 51 terminals.

Rated operational voltage is 60 V AC to IEC. Ambient temperature runs from -50 °C to +75 °C (-58 °F ... +167 °F).

Explosion protection marking is Ex ia ib IIC T6 Gb and Ex tb IIIC T80 °C Db, with Class I, Div. 1,2, Groups A,B,C,D and Class II, Div. 1,2, Groups E,F,G. NEC 500, 505, 506, CEC Section 18 and IEC/EN 60529 are referenced. Certificates are UL, ATEX, IECEx, PESO, NEPSI, KGS, ITRI, ULB and BVIS.

Weight is 2.2 to 10.49 lb. Example types are 8146/2051, 8146/2061, 8146/2073 and 8146/2083, on rails of 35 x 133, 35 x 189 and 35 x 301 mm.

Technical specifications

Type of protectionEx i
Enclosure materialPolyester resin, glass fibre reinforced
Degree of protection (IP)IP66
Rated operational voltage AC IEC60 V
Terminals2.5 mm² / AWG 14
Max. no. of terminals19; 27; 49; 51
Terminal rail35 x 133 mm; 35 x 189 mm; 35 x 301 mm
Ambient temperature-50 °C ... +75 °C (-58 °F ... +167 °F)
Marking (IEC)Ex ia ib IIC T6 Gb; Ex tb IIIC T80 °C Db
Marking (NEC)Class I, Div. 1,2, Groups A,B,C,D; Class II, Div. 1,2, Groups E,F,G
StandardsNEC 500; NEC 505; NEC 506; CEC Section 18; IEC/EN 60529
CertificatesUL, ATEX, IECEx, PESO, NEPSI, KGS, ITRI, ULB, BVIS
Weight2.2 ... 10.49 lb

Part numbers

Show all part numbers (4)

278806, 278807, 278808, 278809

How it compares with similar models

ParameterNEC/IEC Series 8146/2 Ex i Terminal Boxes, Ex ia ib IIC T6 Gb, 60 V, IP66NEC/IEC Series 8146/1 Ex e Terminal Boxes, Polyester Resin, 690 V, IP66NEC/IEC Series 8150 Ex i Terminal Boxes, Stainless Steel 1.4404, IP66, M8 EarthNEC/IEC Series 8150 Ex e Terminal Boxes, Stainless Steel 1.4404, IP66, 690 V
Type of protectionEx iEx eEx iEx e
Enclosure materialPolyester resin, glass fibre reinforcedPolyester resin, glass fibre reinforcedStainless steel 1.4404 (ANSI 316L), brush finishedStainless steel 1.4404 (AISI 316L), brush finished
Rated operational voltage AC IEC60 V690 V—690 V
Max. no. of terminals19; 27; 49; 5110 ... 2619; 279; 13
Terminal rail35 x 133 mm; 35 x 189 mm; 35 x 301 mm—35 x 133 mm; 35 x 189 mm35 x 133 mm; 35 x 189 mm
StandardsNEC 500; NEC 505; NEC 506; CEC Section 18; IEC/EN 60529NEC 500; NEC 505; NEC 506; CEC Section 18; IEC/EN 60529NEC 500; NEC 505; NEC 506; CEC Section 18; IEC 60529NEC 500; NEC 505; NEC 506; CE Code Section 18; IEC 60529

Request a price and lead time

NEC/IEC Series 8146/2 Ex i Terminal Boxes, Ex ia ib IIC T6 Gb, 60 V, IP66. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What explosion protection marking does the 8146/2 carry?

Ex ia ib IIC T6 Gb and Ex tb IIIC T80 °C Db, and Class I, Div. 1,2, Groups A,B,C,D under NEC.

What is the rated voltage?

60 V AC (IEC).

How many terminals can be fitted?

The selection table lists 19, 27, 49 or 51 terminals depending on the size.