Series 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 A

Series 8118 junction boxes carry 4, 5 or 8 mantle terminals depending on design size, with optional miniature fuses. Glass-fibre-reinforced polyester resin enclosure, IP66, zones 1, 2, 21 and 22, marked Ex eb IIC T6 / T5 Gb and Ex ia ib IIC T6 Gb.

Version
Ex e; Ex i
Enclosure material
Glass fibre reinforced polyester resin
Protection degree
IP66
Terminals
4, 5 or 8 mantle terminals; miniature fuses (optional)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8118 junction boxes are fitted with 4, 5 or 8 mantle terminals, depending on the design size. Miniature fuses can be installed in addition as an option, so the boxes also serve for safeguarding. They work as connection or junction boxes and to safeguard electric distributors up to 6.3 A. The Ex e enclosure is glass-fibre-reinforced polyester resin with IP66 protection.

Plastic or metal cable glands can be fitted. The selection table lists black polyamide glands and polyamide stopping plugs in M20 x 1.5 (4 – 13 mm), M25 x 1.5 (7 – 17 mm) and M32 x 1.5 (9 – 21 mm). Wire cross-sections are 4 mm², 6 mm² and 10 mm², and rated voltages 550 V, 750 V and 60 V.

Marking includes Ex eb IIC T6 / T5 Gb, Ex ia ib IIC T6 Gb, Ex tb IIIC T80 °C / T95 °C Db and Ex tb IIIC T80 °C Db, for zones 1, 2, 21 and 22. ATEX, IECEx, NEPSI and PESO certificates are listed, together with KTL, ULB and DNV.

Ambient temperature depends on the version. The selection table gives -60 °C to +40 °C (T6) and up to +55 °C (T5), and some versions are listed at -20 °C ... +75 °C (T6). Weights run from 280 to 500 g.

Ex i versions carry separate part numbers. Example types are 8118/111-400, 8118/111-401, 8118/211-401, 8118/211-403 and 8118/221-899.

Technical specifications

VersionEx e; Ex i
Enclosure materialGlass fibre reinforced polyester resin
Protection degreeIP66
Terminals4, 5 or 8 mantle terminals; miniature fuses (optional)
Wire cross-section4 mm²; 6 mm²; 10 mm²
AC rated operational voltage550 V; 750 V; 60 V
Max current6.3 A
Cable gland sizesM20 x 1.5 (4 – 13 mm); M25 x 1.5 (7 – 17 mm); M32 x 1.5 (9 – 21 mm)
Explosion protectionEx eb IIC T6 / T5 Gb; Ex ia ib IIC T6 Gb; Ex tb IIIC T80 °C / T95 °C Db
Zones1, 2, 21, 22
Ambient temperature-60 °C ... +40 °C (T6); -60 °C ... +55 °C (T5)
CertificatesATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV
Weight280 - 500 g

Part numbers

Show all part numbers (6)

133218, 133104, 133084, 133219, 133248, 133077

How it compares with similar models

ParameterSeries 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 ASeries 8102 Junction Boxes, Ex e / Ex i, Polyester Resin, 5 Terminals 4 mm², IP66Series 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66Series 8118 Terminal Boxes with 221 Ex Spring-Lever Terminals, Ex e, 440 V
VersionEx e; Ex iEx e; Ex iEx e; Ex e with earth plate; Ex i—
Enclosure materialGlass fibre reinforced polyester resinPolyester resin, glass fibre reinforcedPolyester resin, glass fibre reinforcedPolyester resin, glass fibre reinforced
AC rated operational voltage550 V; 750 V; 60 V—690 V (Ex e); 550 V (Ex e with earth plate); 60 V (Ex i)440 V
Ambient temperature-60 °C ... +40 °C (T6); -60 °C ... +55 °C (T5)—-40 °C ... +40 °C (T6); -40 °C ... +55 °C (T5)-55 °C ... +75 °C (T6)
CertificatesATEX, IECEx, NEPSI, PESO, KTL, ULB, DNVATEX, IECEx, NEPSIATEX, IECEx, NEPSI, PESO, KTL, ULB, DNVATEX, IECEx, PESO, NEPSI, KTL, ULB, DNV

Request a price and lead time

Series 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can fuses be installed in an 8118 box?

Yes. Miniature fuses can be added as an option, and the box can safeguard electric distributors up to 6.3 A.

How many terminals do the boxes have?

4, 5 or 8 mantle terminals depending on design size, with 4, 6 or 10 mm² cross-sections.

What explosion protection marking applies?

Ex eb IIC T6 / T5 Gb, Ex ia ib IIC T6 Gb and Ex tb IIIC T80 °C / T95 °C Db, for zones 1, 2, 21 and 22.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides