Series 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 A
Series 8118 junction boxes carry 4, 5 or 8 mantle terminals depending on design size, with optional miniature fuses. Glass-fibre-reinforced polyester resin enclosure, IP66, zones 1, 2, 21 and 22, marked Ex eb IIC T6 / T5 Gb and Ex ia ib IIC T6 Gb.
- Version
- Ex e; Ex i
- Enclosure material
- Glass fibre reinforced polyester resin
- Protection degree
- IP66
- Terminals
- 4, 5 or 8 mantle terminals; miniature fuses (optional)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Series 8118 junction boxes are fitted with 4, 5 or 8 mantle terminals, depending on the design size. Miniature fuses can be installed in addition as an option, so the boxes also serve for safeguarding. They work as connection or junction boxes and to safeguard electric distributors up to 6.3 A. The Ex e enclosure is glass-fibre-reinforced polyester resin with IP66 protection.
Plastic or metal cable glands can be fitted. The selection table lists black polyamide glands and polyamide stopping plugs in M20 x 1.5 (4 – 13 mm), M25 x 1.5 (7 – 17 mm) and M32 x 1.5 (9 – 21 mm). Wire cross-sections are 4 mm², 6 mm² and 10 mm², and rated voltages 550 V, 750 V and 60 V.
Marking includes Ex eb IIC T6 / T5 Gb, Ex ia ib IIC T6 Gb, Ex tb IIIC T80 °C / T95 °C Db and Ex tb IIIC T80 °C Db, for zones 1, 2, 21 and 22. ATEX, IECEx, NEPSI and PESO certificates are listed, together with KTL, ULB and DNV.
Ambient temperature depends on the version. The selection table gives -60 °C to +40 °C (T6) and up to +55 °C (T5), and some versions are listed at -20 °C ... +75 °C (T6). Weights run from 280 to 500 g.
Ex i versions carry separate part numbers. Example types are 8118/111-400, 8118/111-401, 8118/211-401, 8118/211-403 and 8118/221-899.
Technical specifications
| Version | Ex e; Ex i |
|---|---|
| Enclosure material | Glass fibre reinforced polyester resin |
| Protection degree | IP66 |
| Terminals | 4, 5 or 8 mantle terminals; miniature fuses (optional) |
| Wire cross-section | 4 mm²; 6 mm²; 10 mm² |
| AC rated operational voltage | 550 V; 750 V; 60 V |
| Max current | 6.3 A |
| Cable gland sizes | M20 x 1.5 (4 – 13 mm); M25 x 1.5 (7 – 17 mm); M32 x 1.5 (9 – 21 mm) |
| Explosion protection | Ex eb IIC T6 / T5 Gb; Ex ia ib IIC T6 Gb; Ex tb IIIC T80 °C / T95 °C Db |
| Zones | 1, 2, 21, 22 |
| Ambient temperature | -60 °C ... +40 °C (T6); -60 °C ... +55 °C (T5) |
| Certificates | ATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV |
| Weight | 280 - 500 g |
Part numbers
Show all part numbers (6)
133218, 133104, 133084, 133219, 133248, 133077
How it compares with similar models
| Parameter | Series 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 A | Series 8102 Junction Boxes, Ex e / Ex i, Polyester Resin, 5 Terminals 4 mm², IP66 | Series 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66 | Series 8118 Terminal Boxes with 221 Ex Spring-Lever Terminals, Ex e, 440 V |
|---|---|---|---|---|
| Version | Ex e; Ex i | Ex e; Ex i | Ex e; Ex e with earth plate; Ex i | — |
| Enclosure material | Glass fibre reinforced polyester resin | Polyester resin, glass fibre reinforced | Polyester resin, glass fibre reinforced | Polyester resin, glass fibre reinforced |
| AC rated operational voltage | 550 V; 750 V; 60 V | — | 690 V (Ex e); 550 V (Ex e with earth plate); 60 V (Ex i) | 440 V |
| Ambient temperature | -60 °C ... +40 °C (T6); -60 °C ... +55 °C (T5) | — | -40 °C ... +40 °C (T6); -40 °C ... +55 °C (T5) | -55 °C ... +75 °C (T6) |
| Certificates | ATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV | ATEX, IECEx, NEPSI | ATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV | ATEX, IECEx, PESO, NEPSI, KTL, ULB, DNV |
Request a price and lead time
Series 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can fuses be installed in an 8118 box?
Yes. Miniature fuses can be added as an option, and the box can safeguard electric distributors up to 6.3 A.
How many terminals do the boxes have?
4, 5 or 8 mantle terminals depending on design size, with 4, 6 or 10 mm² cross-sections.
What explosion protection marking applies?
Ex eb IIC T6 / T5 Gb, Ex ia ib IIC T6 Gb and Ex tb IIIC T80 °C / T95 °C Db, for zones 1, 2, 21 and 22.