International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Series 8146/5 safety temperature monitors and limiters, 230 V AC, 25 A (T6), IP66, Ex db eb IIC T6 Gb

Series 8146/5 safety temperature monitors and limiters disconnect the system when temperature passes a set limit. Switching capacity is up to 25 A, in a glass fibre reinforced polyester enclosure rated IP66 for Zone 1/2/21/22.

Types
Safety temperature monitor; safety temperature limiter; combined unit
AC rated operational voltage
230 V
Rated operational current
25 A (T6)
Max. output load 1 to 2
230 V AC1 / 25 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8146/5 safety temperature monitors and limiters disconnect the system after an adjustable limiting value is exceeded. Limiters remain disconnected, while monitors switch back on once the permissible temperature is reached. The devices trip when the temperature exceeds or falls below a user-defined value, with a switching capacity up to 25 A.

Both types prevent reconnection if the fluid-filled measuring system is leaking. The set value can be read from outside through a sight glass. Standardised versions in an Ex e enclosure of Series 8146 exist, and customised solutions are made on request.

The enclosure is glass fibre reinforced polyester resin with IP66 protection, and there is 1 change-over contact. The capillary tube is 1 m long and 1.5 mm in diameter, and the sensor diameter is 6 mm. The cable entry is black polyamide, 1 × M20 for Ø4 ... 13 mm, or 2 × M20 in the combined unit.

Rated voltage is 230 V AC and rated operational current is 25 A (T6). Maximum output load is 230 V AC1 / 25 A on contacts 1 to 2 and 230 V AC1 / 2 A on contacts 1 to 4. Ambient temperature runs from -60 °C to +40 °C. Ranges are -20 to 50 °C, 0 to 120 °C and 0 to 190 °C. Weight is 1 kg to 1.44 kg.

Explosion protection is Ex db eb IIC T6 Gb and Ex tb IIIC T80 °C Db, for Zone 1/2/21/22. The standard is EN 14597. Certificates are ATEX (PTB), IECEx (PTB), India (PESO) and China (NEPSI).

Technical specifications

TypesSafety temperature monitor; safety temperature limiter; combined unit
AC rated operational voltage230 V
Rated operational current25 A (T6)
Max. output load 1 to 2230 V AC1 / 25 A
Max. output load 1 to 4230 V AC1 / 2 A
Contacts1 change-over contact
Degree of protectionIP66
Enclosure materialPolyester resin, glass fibre reinforced
Measuring ranges-20 to 50 °C; 0 to 120 °C; 0 to 190 °C
Capillary tubeLength 1 m, diameter 1.5 mm
Sensor diameter6 mm
Cable entryPolyamide, black; 1 × M20 Ø4 ... 13 mm (2 × M20 combined)
Ambient temperature-60 °C ... +40 °C
Explosion protectionEx db eb IIC T6 Gb; Ex tb IIIC T80 °C Db
Weight1 ... 1.44 kg

Part numbers

Show all part numbers (6)

8146/5041-STW25A/-20- +50°C (136043), 8146/5041-STW25A/0- +190°C (136081), 8146/5041-STB25A/+0...+120°C (136011), 8146/5051-STW25A+STB25A (269562), 8146/5041-STW0, 1A/-20- +50°C (270794)

How it compares with similar models

ParameterSeries 8146/5 safety temperature monitors and limiters, 230 V AC, 25 A (T6), IP66, Ex db eb IIC T6 GbNEC/IEC Series 8146/2 Ex i Terminal Boxes, Ex ia ib IIC T6 Gb, 60 V, IP66Series 8040/11-V30 installation switch, 690 V AC, 16 A, IP66TEF1058 pipe mounted capillary tube thermostat for heat tracing, Ex db eb IIC T6, 230 V, 16 A, IP66/67
Rated operational current25 A (T6)—16 A (T6)16 A (T6)
Degree of protectionIP66—IP66IP66/IP67
Enclosure materialPolyester resin, glass fibre reinforcedPolyester resin, glass fibre reinforcedPolyester resin, glass fibre reinforcedStainless steel 1.4404, electropolished
Ambient temperature-60 °C ... +40 °C-50 °C ... +75 °C (-58 °F ... +167 °F)—-50 °C ... +50 °C
Explosion protectionEx db eb IIC T6 Gb; Ex tb IIIC T80 °C Db—Ex db eb IIC T6 Gb; Ex tb IIIC T80 °C DbEx db eb IIC T6; E II 2 G Ex db eb IIC T6
Weight1 ... 1.44 kg2.2 ... 10.49 lb600 g (off switch); 615 g (two-way switch)—

Request a price and lead time

Series 8146/5 safety temperature monitors and limiters, 230 V AC, 25 A (T6), IP66, Ex db eb IIC T6 Gb. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does a monitor differ from a limiter?

A limiter stays disconnected after a limit is exceeded, while a monitor switches back on when the permissible temperature is reached.

What happens if the measuring system leaks?

Reconnection is prevented if the fluid-filled measuring system is leaking. The set value shows through a sight glass.

What ranges and switching capacity are offered?

Ranges are -20 to 50 °C, 0 to 120 °C and 0 to 190 °C. Switching is up to 25 A, 230 V AC1 / 25 A on contacts 1 to 2.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides