International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TEF1058 pipe mounted capillary tube thermostat for heat tracing, Ex db eb IIC T6, 230 V, 16 A, IP66/67

The TEF1058 capillary tube thermostat mounts on a pipe and has one change-over contact. Ranges are -20 to 50 °C, 0 to 120 °C and 0 to 200 °C, at 230 V AC and 16 A (T6), in a 1.4404 stainless steel enclosure rated IP66/67.

Application
Pipe mounted safety temperature monitor, capillary tube thermostat
Measuring ranges
-20 to 50 °C; 0 to 120 °C; 0 to 200 °C
Contacts
1 change-over contact
Rated operational voltage AC
230 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TEF1058 capillary tube thermostat is intended for heat tracing and de-ice systems. The catalogue lists it as a safety temperature monitor for pipe mounting with one change-over contact. It is recommended for up to 4 heating cables and suits Zone 1 and 2.

Three measuring ranges are offered: -20 to 50 °C (TEF10582560), 0 to 120 °C (TEF10582561) and 0 to 200 °C (TEF10582562). Rated operational voltage is 230 V AC and rated operational current is 16 A (T6). Maximum output AC load is L-4 2 (0.4) A cos φ 1 (0.6) and L-2 16 (2.5) A cos φ 1 (0.6).

The enclosure is electropolished stainless steel 1.4404 (AISI 316L), with protection IP66/IP67, or IP67 without breather. A stainless steel type label is spot welded to the cover, and several earthing alternatives exist. Ambient temperature runs from -50 °C to +50 °C.

Entries are 1 brass M25 cable gland for Ø13 ... 17 mm, 6 brass M25 × 1.5 stopping plugs, 1 M25 × 1.5 breather and 2 M25 transition units. Terminals are 3 two-conductor supply terminals of 10 mm², 5 two-conductor output terminals of 2.5 mm² and 4 two-conductor PE terminals of 10 mm².

Explosion protection is Ex db eb IIC T6 (IECEx) and E II 2 G Ex db eb IIC T6 (ATEX). Standards are IEC 60079-0, IEC 60079-1, IEC 60079-31 and NORSOK. The certificate is ATEX (PRE).

Technical specifications

ApplicationPipe mounted safety temperature monitor, capillary tube thermostat
Measuring ranges-20 to 50 °C; 0 to 120 °C; 0 to 200 °C
Contacts1 change-over contact
Rated operational voltage AC230 V
Rated operational current16 A (T6)
Max. output AC load, L-42 (0.4) A cos φ 1 (0.6)
Max. output AC load, L-216 (2.5) A cos φ 1 (0.6)
Degree of protectionIP66/IP67
Enclosure materialStainless steel 1.4404, electropolished
Ambient temperature-50 °C ... +50 °C
Explosion protectionEx db eb IIC T6; E II 2 G Ex db eb IIC T6
Entries1 × cable gland M25 Ø13 ... 17 mm; 6 × stopping plug M25 × 1.5; 1 × breather M25 × 1.5; 2 × transition unit M25
Terminals3 × supply 10 mm²; 5 × output 2.5 mm²; 4 × PE 10 mm²

Part numbers

Show all part numbers (3)

TEF10582560 (259549), TEF10582561 (259550), TEF10582562 (259551)

How it compares with similar models

ParameterTEF1058 pipe mounted capillary tube thermostat for heat tracing, Ex db eb IIC T6, 230 V, 16 A, IP66/67TEF1058 wall mounted capillary tube thermostat for heat tracing, Ex db eb IIC T6, 230 V, 16 A, IP66/67TEF1058 pipe mounted heat tracing junction box, 4 mm², Ex eb IIC T5 Gb, IP66/67TEF1058 wall mounted junction box for heat tracing, Ex eb IIC T5 Gb, IP66/67
ApplicationPipe mounted safety temperature monitor, capillary tube thermostatWall mounted safety temperature monitor, capillary tube thermostatPipe mounted junction box for heat tracingWall mounted junction box for heat tracing and de-ice
Enclosure materialStainless steel 1.4404, electropolishedStainless steel 1.4404, electropolishedStainless steel 1.4404 (AISI 316L), electropolished or pickledStainless steel 1.4404 (AISI 316L), electropolished or pickled
Ambient temperature-50 °C ... +50 °C-50 °C ... +50 °C-40 °C ... +40 °C-50 °C ... +50 °C
Entries1 × cable gland M25 Ø13 ... 17 mm; 6 × stopping plug M25 × 1.5; 1 × breather M25 × 1.5; 2 × transition unit M251 × cable gland M25 Ø13 ... 17 mm; 8 × stopping plug M25 × 1.5; 1 × breather M25 × 1.51 × E204/622 M25/D9 (Ø13 - 17 mm) or 4 × Ø252 × E204/622 M25/D9 (Ø13 - 17 mm) or 7 × Ø25

Request a price and lead time

TEF1058 pipe mounted capillary tube thermostat for heat tracing, Ex db eb IIC T6, 230 V, 16 A, IP66/67. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which temperature ranges does the series offer?

Three ranges, -20 to 50 °C, 0 to 120 °C and 0 to 200 °C, each with one change-over contact.

What is the switching capacity of the thermostat?

230 V AC and 16 A (T6). Output loads are up to 2 (0.4) A for L-4 and 16 (2.5) A for L-2, at cos φ 1 (0.6).

What are the explosion protection marking and protection degree?

Ex db eb IIC T6 with ATEX E II 2 G, and IP66/IP67.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides