International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TEF1058 pipe mounted heat tracing junction box, 4 mm², Ex eb IIC T5 Gb, IP66/67

Mounted on a pipe, this TEF1058 junction box connects heating cables in heat tracing systems with a 4 mm² cross-section. Its 1.4404 (AISI 316L) stainless steel enclosure is rated IP66/67 and marked Ex eb IIC T5 Gb, for -40 °C to +40 °C.

Application
Pipe mounted junction box for heat tracing
Enclosure material
Stainless steel 1.4404 (AISI 316L), electropolished or pickled
Protection degree
IP66/67, IP67 without breather
Connection cross-section
4 mm²

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The pipe mounted TEF1058 junction box connects heating cables in heat tracing systems. It is used on oil installations, in the petrochemical industry and in other industries with rough environments. It is recommended for up to 2 heating cables and suits Zone 1 and Zone 2.

The enclosure is acid proof stainless steel 1.4404 (AISI 316L), electropolished or pickled, giving maximum strength and corrosion resistance. A stainless steel type label is spot welded to the cover, and several earthing alternatives are available.

The degree of protection is IP66/67, or IP67 without breather. Connection cross-section is 4 mm². The approximate size is 189 × 189 × 248 mm, and ambient temperature runs from -40 °C to +40 °C. Explosion protection is Ex eb IIC T5 Gb to IECEx and E II 2 G Ex eb IIC T5 Gb to ATEX.

The types differ in their entries. TEF10581136 and TEF10581116 carry 1 cable gland E204/622 M25/D9 (Ø13 - 17 mm), 1 M25 stopping plug and 1 M25 breather. TEF10581126 and TEF10581106 have 4 Ø25 entries. The label kit is not included. The certificate is ATEX (PRE).

Technical specifications

ApplicationPipe mounted junction box for heat tracing
Enclosure materialStainless steel 1.4404 (AISI 316L), electropolished or pickled
Protection degreeIP66/67, IP67 without breather
Connection cross-section4 mm²
Dimensions~ 189 × ~ 189 × 248 mm
Ambient temperature-40 °C ... +40 °C
Explosion protection (IECEx)Ex eb IIC T5 Gb
Explosion protection (ATEX)E II 2 G Ex eb IIC T5 Gb
Heating cablesUp to 2 (recommended)
Entries1 × E204/622 M25/D9 (Ø13 - 17 mm) or 4 × Ø25

Part numbers

Show all part numbers (4)

TEF10581136 (259481), TEF10581126 (259480), TEF10581116 (259479), TEF10581106 (259478)

How it compares with similar models

ParameterTEF1058 pipe mounted heat tracing junction box, 4 mm², Ex eb IIC T5 Gb, IP66/67TEF1058 wall mounted heat tracing junction box, 4 mm², Ex eb IIC T5 Gb, IP66/67TEF1058 pipe mounted junction box for heat tracing, Ex eb IIC T5 Gb, IP66/67TEF1058 wall mounted junction box for heat tracing, Ex eb IIC T5 Gb, IP66/67
ApplicationPipe mounted junction box for heat tracingWall mounted junction box for heat tracingPipe mounted junction box for heat tracing and de-iceWall mounted junction box for heat tracing and de-ice
Protection degreeIP66/67, IP67 without breatherIP66/67, IP67 without breatherIP66/IP67, IP67 without breatherIP66/67, IP67 without breather
Connection cross-section4 mm²4 mm²6 mm²6 mm²
Dimensions~ 189 × ~ 189 × 248 mm125 × 147 × 112 mm—184 × 184 × 120 mm
Ambient temperature-40 °C ... +40 °C-40 °C ... +40 °C—-50 °C ... +50 °C
Entries1 × E204/622 M25/D9 (Ø13 - 17 mm) or 4 × Ø251 × E204/622 M25/D9 (Ø13 - 17 mm) or 4 × Ø252 × E204/622 M25/D9 (Ø13 - 17 mm) or 5 × Ø252 × E204/622 M25/D9 (Ø13 - 17 mm) or 7 × Ø25

Request a price and lead time

TEF1058 pipe mounted heat tracing junction box, 4 mm², Ex eb IIC T5 Gb, IP66/67. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which entry versions does the pipe mounted box have?

One E204/622 M25/D9 cable gland (Ø13 - 17 mm) with an M25 stopping plug and breather, or 4 Ø25 entries.

What are the connection cross-section and temperature range?

The connection cross-section is 4 mm² and ambient temperature is -40 °C to +40 °C.

How many heating cables are recommended?

Up to 2 heating cables, and the box suits Zone 1 and 2.