International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TEF1058 pipe mounted junction box for heat tracing, Ex eb IIC T5 Gb, IP66/67

The TEF1058 pipe mounted junction box serves heat tracing and de-ice systems in Zone 1 and 2. Its acid proof stainless steel 1.4404 (AISI 316L) enclosure is rated IP66/67 and marked Ex eb IIC T5 Gb.

Application
Pipe mounted junction box for heat tracing and de-ice
Enclosure material
Stainless steel 1.4404 (AISI 316L), electropolished or pickled
Protection degree
IP66/IP67, IP67 without breather
Connection cross-section
6 mm²

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TEF1058 pipe mounted junction box is built for heat tracing and de-ice systems in rough environments. It is recommended for up to 2 heating cables and suits Zone 1, Zone 2 and Safe Area.

The enclosure is acid proof stainless steel 1.4404 (AISI 316L), electropolished or pickled, for maximum strength and corrosion resistance. A stainless steel type label is spot welded to the cover, and several earthing alternatives are offered.

Protection is IP66/IP67, or IP67 without breather. Connection cross-section is 6 mm². Explosion protection is Ex eb IIC T5 Gb (IECEx) and E II 2 G Ex eb IIC T5 Gb (ATEX).

The versions differ in entries and weight. TEF10581636 and TEF10581616 have 2 cable glands E204/622 M25/D9 (Ø13 - 17 mm), 2 M25 stopping plugs and 1 M25 breather, and weigh 2.18 kg. TEF10581646 and TEF10581606 have 5 Ø25 entries with temporary plugs and weigh 1.68 kg. The label kit is not included.

Typical uses are hazardous areas, chemical and petrochemical industries, and industrial plants needing frost protection or temperature maintenance, to NORSOK requirements. The certificate is ATEX (PRE).

Technical specifications

ApplicationPipe mounted junction box for heat tracing and de-ice
Enclosure materialStainless steel 1.4404 (AISI 316L), electropolished or pickled
Protection degreeIP66/IP67, IP67 without breather
Connection cross-section6 mm²
Explosion protection (IECEx)Ex eb IIC T5 Gb
Explosion protection (ATEX)E II 2 G Ex eb IIC T5 Gb
Zones1, 2 and Safe Area
Heating cablesUp to 2 (recommended)
Entries2 × E204/622 M25/D9 (Ø13 - 17 mm) or 5 × Ø25
Weight2.18 kg (with glands); 1.68 kg (5 × Ø25 entries)
StandardsNORSOK

Part numbers

Show all part numbers (4)

TEF10581646 (259485), TEF10581636 (259484), TEF10581616 (259483), TEF10581606 (259482)

How it compares with similar models

ParameterTEF1058 pipe mounted junction box for heat tracing, Ex eb IIC T5 Gb, IP66/67TEF1058 wall mounted junction box for heat tracing, Ex eb IIC T5 Gb, IP66/67TEF1058 pipe mounted heat tracing junction box, 4 mm², Ex eb IIC T5 Gb, IP66/67TEF1058 wall mounted heat tracing junction box, 4 mm², Ex eb IIC T5 Gb, IP66/67
ApplicationPipe mounted junction box for heat tracing and de-iceWall mounted junction box for heat tracing and de-icePipe mounted junction box for heat tracingWall mounted junction box for heat tracing
Protection degreeIP66/IP67, IP67 without breatherIP66/67, IP67 without breatherIP66/67, IP67 without breatherIP66/67, IP67 without breather
Connection cross-section6 mm²6 mm²4 mm²4 mm²
Entries2 × E204/622 M25/D9 (Ø13 - 17 mm) or 5 × Ø252 × E204/622 M25/D9 (Ø13 - 17 mm) or 7 × Ø251 × E204/622 M25/D9 (Ø13 - 17 mm) or 4 × Ø251 × E204/622 M25/D9 (Ø13 - 17 mm) or 4 × Ø25
StandardsNORSOKNORSOK—IEC 60079-0; IEC 60079-7

Request a price and lead time

TEF1058 pipe mounted junction box for heat tracing, Ex eb IIC T5 Gb, IP66/67. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which entry versions does the pipe mounted box offer?

Two E204/622 M25/D9 cable glands (Ø13 - 17 mm) with 2 M25 stopping plugs and an M25 breather, or 5 Ø25 entries with temporary plugs.

What are the weight and explosion protection marking?

The weight is 2.18 kg with glands or 1.68 kg with Ø25 entries. The marking is Ex eb IIC T5 Gb, ATEX E II 2 G.

How many heating cables are recommended?

Up to 2 heating cables, with a connection cross-section of 6 mm².

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides