Series 8040/11-V30 installation switch, 690 V AC, 16 A, IP66
Series 8040/11-V30 installation switches switch lighting systems in hazardous areas, Zone 1/2/21/22. They come as a two-pole off switch or two-way switch in a glass fibre reinforced polyester resin enclosure rated IP66.
- Versions
- Two-pole off switch or two-pole two-way switch
- AC rated operational voltage
- 690 V
- DC rated operational voltage
- 220 V
- Rated operational current
- 16 A (T6)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Series 8040/11-V30 installation switches are used for switching lighting systems. Two versions exist: a two-pole off switch and a two-pole two-way switch. The enclosure is glass fibre reinforced polyester resin, with IP66 protection to IEC/EN 60529.
The 90° rotary actuator shows the switching position clearly, which helps when the lighting system and the switch are in different rooms. Its fluorescent finish makes orientation possible if the lighting fails. Positions are marked 0/1 or OFF/ON.
Rated operational voltage is 690 V AC or 220 V DC, and rated operational current is 16 A (T6). Terminals accept 1.5 mm² minimum, 2.5 mm² finely stranded and 4 mm² solid conductors at most. The cable entry is 1 × M25 for cable Ø 7 ... 17 mm, and two M25 × 1.5 stopping plugs are fitted.
Explosion protection is Ex db eb IIC T6 Gb and Ex tb IIIC T80 °C Db, for Zone 1/2/21/22. With NBR sealing the ambient range is -20 °C to +55 °C (T6) and up to +60 °C (T5). Silicone sealing extends the lower limit to -60 °C. The off switch weighs 600 g and the two-way switch 615 g.
Certificates cover ATEX (PTB), IECEx (PTB), India (PESO), Brazil (ULB), China (NEPSI) and Taiwan (ITRI), with DNV ship approval.
Technical specifications
| Versions | Two-pole off switch or two-pole two-way switch |
|---|---|
| AC rated operational voltage | 690 V |
| DC rated operational voltage | 220 V |
| Rated operational current | 16 A (T6) |
| Degree of protection | IP66 |
| Enclosure material | Polyester resin, glass fibre reinforced |
| Explosion protection | Ex db eb IIC T6 Gb; Ex tb IIIC T80 °C Db |
| Ambient temperature, NBR seal | -20 °C ... +55 °C (T6); -20 °C ... +60 °C (T5) |
| Ambient temperature, silicone seal | -60 °C ... +55 °C (T6); -60 °C ... +60 °C (T5) |
| Connection terminals | 1.5 mm² min.; finely stranded 2.5 mm² max.; solid 4 mm² max. |
| Cable entries | 1 × M25 Ø 7 ... 17 mm; stopping plugs 2 × M25 × 1.5 |
| Weight | 600 g (off switch); 615 g (two-way switch) |
Part numbers
Show all part numbers (4)
8040/11-V30-033-B (245655), 8040/11-V30-033-S (245656), 8040/11-V30-035-B (245657), 8040/11-V30-035-S (245658)
How it compares with similar models
| Parameter | Series 8040/11-V30 installation switch, 690 V AC, 16 A, IP66 | Series 8146/5 safety temperature monitors and limiters, 230 V AC, 25 A (T6), IP66, Ex db eb IIC T6 Gb | Series 8102 Junction Boxes, Ex e / Ex i, Polyester Resin, 5 Terminals 4 mm², IP66 | Series 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 A |
|---|---|---|---|---|
| AC rated operational voltage | 690 V | 230 V | — | 550 V; 750 V; 60 V |
| Enclosure material | Polyester resin, glass fibre reinforced | Polyester resin, glass fibre reinforced | Polyester resin, glass fibre reinforced | Glass fibre reinforced polyester resin |
| Explosion protection | Ex db eb IIC T6 Gb; Ex tb IIIC T80 °C Db | Ex db eb IIC T6 Gb; Ex tb IIIC T80 °C Db | — | Ex eb IIC T6 / T5 Gb; Ex ia ib IIC T6 Gb; Ex tb IIIC T80 °C / T95 °C Db |
| Weight | 600 g (off switch); 615 g (two-way switch) | 1 ... 1.44 kg | 0.200 - 0.330 kg | 280 - 500 g |
Request a price and lead time
Series 8040/11-V30 installation switch, 690 V AC, 16 A, IP66. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which switching versions does Series 8040/11-V30 offer?
A two-pole off switch and a two-pole two-way switch. The position shows as 0/1 or OFF/ON.
What ambient temperature range applies with each seal?
NBR sealing gives -20 °C to +55 °C (T6) and up to +60 °C (T5). Silicone sealing starts at -60 °C with the same upper limits.
What explosion protection marking and zones apply?
Ex db eb IIC T6 Gb and Ex tb IIIC T80 °C Db, for Zone 1/2/21/22.