Series 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66
Series 8118 terminal boxes are equipped with terminal blocks and cable glands to customer specification, with miniature fuses if required. Three design sizes, glass-fibre-reinforced polyester resin enclosure, IP66, zones 1, 2, 21 and 22, up to 690 V.
- Version
- Ex e; Ex e with earth plate; Ex i
- Enclosure material
- Polyester resin, glass fibre reinforced
- Protection degree
- IP66
- AC rated operational voltage
- 690 V (Ex e); 550 V (Ex e with earth plate); 60 V (Ex i)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Series 8118 terminal boxes are equipped, in accordance with customer specifications, with various terminal blocks and cable glands made from plastic or metal. Miniature fuses are fitted if required. The boxes come in 3 design sizes and are made from glass fibre reinforced polyester resin. The compact, impact-resistant enclosure is also offered with an integrated metal bracket for mounting of cable glands.
Rated voltage is 690 V for Ex e, 550 V for Ex e with earth plate and 60 V for Ex i. Up to 36 conductors can be connected, depending on size and current, with cross-sections of 1.5 mm², 2.5 mm², 4 mm² and 6 mm². Enclosure sizes are 8118/112, 8118/114, 8118/122, 8118/124, 8118/132 and 8118/134. IEC 61439 is listed.
Terminals sit on mounting rails of 35 x 50 mm, 15 x 70 mm, 15 x 63 mm or 35 x 85 mm, and a version for installation in enclosure SZ 3 exists. One SZ 3 example has 2 x M25 x 1.5 and 1 x M10 with an M4 PE connection in the centre.
Protection is IP66 for zones 1, 2, 21 and 22. Certificates are ATEX, IECEx, NEPSI, PESO, KTL and ULB, plus DNV. The selection table gives -40 °C to +40 °C (T6) and up to +55 °C (T5), and the version filter also shows -20, -50 and +75 °C.
Glands and plugs come in M20 x 1.5 and M25 x 1.5, and versions with through holes and no cable entry are listed.
Technical specifications
| Version | Ex e; Ex e with earth plate; Ex i |
|---|---|
| Enclosure material | Polyester resin, glass fibre reinforced |
| Protection degree | IP66 |
| AC rated operational voltage | 690 V (Ex e); 550 V (Ex e with earth plate); 60 V (Ex i) |
| Max. number of conductors | Up to 36 (depending on size and current) |
| Conductor cross-section | 1.5 mm²; 2.5 mm²; 4 mm²; 6 mm² |
| Enclosure sizes | 8118/112; 8118/114; 8118/122; 8118/124; 8118/132; 8118/134 |
| Mounting rail | 35 x 50 mm; 15 x 70 mm; 15 x 63 mm; 35 x 85 mm |
| Gland thread | M20 x 1.5; M25 x 1.5 |
| Zones | 1, 2, 21, 22 |
| Ambient temperature | -40 °C ... +40 °C (T6); -40 °C ... +55 °C (T5) |
| Standard | IEC 61439 |
| Certificates | ATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV |
Part numbers
Show all part numbers (3)
133123, 349591, 224642
How it compares with similar models
| Parameter | Series 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66 | Series 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 A | Series 8102 Junction Boxes, Ex e / Ex i, Polyester Resin, 5 Terminals 4 mm², IP66 | NEC/IEC Series 8146/2 Ex i Terminal Boxes, Ex ia ib IIC T6 Gb, 60 V, IP66 |
|---|---|---|---|---|
| Version | Ex e; Ex e with earth plate; Ex i | Ex e; Ex i | Ex e; Ex i | — |
| Enclosure material | Polyester resin, glass fibre reinforced | Glass fibre reinforced polyester resin | Polyester resin, glass fibre reinforced | Polyester resin, glass fibre reinforced |
| Ambient temperature | -40 °C ... +40 °C (T6); -40 °C ... +55 °C (T5) | -60 °C ... +40 °C (T6); -60 °C ... +55 °C (T5) | — | -50 °C ... +75 °C (-58 °F ... +167 °F) |
| Certificates | ATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV | ATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV | ATEX, IECEx, NEPSI | UL, ATEX, IECEx, PESO, NEPSI, KGS, ITRI, ULB, BVIS |
Request a price and lead time
Series 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many conductors can be connected?
Up to 36, depending on size and current, with cross-sections of 1.5, 2.5, 4 or 6 mm².
Which enclosure sizes does the series offer?
Three design sizes, listed as 8118/112, 8118/114, 8118/122, 8118/124, 8118/132 and 8118/134.
What voltages are the boxes rated for?
690 V for Ex e, 550 V for Ex e with earth plate and 60 V for Ex i.