Series 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66

Series 8118 terminal boxes are equipped with terminal blocks and cable glands to customer specification, with miniature fuses if required. Three design sizes, glass-fibre-reinforced polyester resin enclosure, IP66, zones 1, 2, 21 and 22, up to 690 V.

Version
Ex e; Ex e with earth plate; Ex i
Enclosure material
Polyester resin, glass fibre reinforced
Protection degree
IP66
AC rated operational voltage
690 V (Ex e); 550 V (Ex e with earth plate); 60 V (Ex i)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8118 terminal boxes are equipped, in accordance with customer specifications, with various terminal blocks and cable glands made from plastic or metal. Miniature fuses are fitted if required. The boxes come in 3 design sizes and are made from glass fibre reinforced polyester resin. The compact, impact-resistant enclosure is also offered with an integrated metal bracket for mounting of cable glands.

Rated voltage is 690 V for Ex e, 550 V for Ex e with earth plate and 60 V for Ex i. Up to 36 conductors can be connected, depending on size and current, with cross-sections of 1.5 mm², 2.5 mm², 4 mm² and 6 mm². Enclosure sizes are 8118/112, 8118/114, 8118/122, 8118/124, 8118/132 and 8118/134. IEC 61439 is listed.

Terminals sit on mounting rails of 35 x 50 mm, 15 x 70 mm, 15 x 63 mm or 35 x 85 mm, and a version for installation in enclosure SZ 3 exists. One SZ 3 example has 2 x M25 x 1.5 and 1 x M10 with an M4 PE connection in the centre.

Protection is IP66 for zones 1, 2, 21 and 22. Certificates are ATEX, IECEx, NEPSI, PESO, KTL and ULB, plus DNV. The selection table gives -40 °C to +40 °C (T6) and up to +55 °C (T5), and the version filter also shows -20, -50 and +75 °C.

Glands and plugs come in M20 x 1.5 and M25 x 1.5, and versions with through holes and no cable entry are listed.

Technical specifications

VersionEx e; Ex e with earth plate; Ex i
Enclosure materialPolyester resin, glass fibre reinforced
Protection degreeIP66
AC rated operational voltage690 V (Ex e); 550 V (Ex e with earth plate); 60 V (Ex i)
Max. number of conductorsUp to 36 (depending on size and current)
Conductor cross-section1.5 mm²; 2.5 mm²; 4 mm²; 6 mm²
Enclosure sizes8118/112; 8118/114; 8118/122; 8118/124; 8118/132; 8118/134
Mounting rail35 x 50 mm; 15 x 70 mm; 15 x 63 mm; 35 x 85 mm
Gland threadM20 x 1.5; M25 x 1.5
Zones1, 2, 21, 22
Ambient temperature-40 °C ... +40 °C (T6); -40 °C ... +55 °C (T5)
StandardIEC 61439
CertificatesATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV

Part numbers

Show all part numbers (3)

133123, 349591, 224642

How it compares with similar models

ParameterSeries 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66Series 8118 Junction Boxes, Ex e / Ex i, 4, 5 or 8 Terminals, IP66, up to 6.3 ASeries 8102 Junction Boxes, Ex e / Ex i, Polyester Resin, 5 Terminals 4 mm², IP66NEC/IEC Series 8146/2 Ex i Terminal Boxes, Ex ia ib IIC T6 Gb, 60 V, IP66
VersionEx e; Ex e with earth plate; Ex iEx e; Ex iEx e; Ex i—
Enclosure materialPolyester resin, glass fibre reinforcedGlass fibre reinforced polyester resinPolyester resin, glass fibre reinforcedPolyester resin, glass fibre reinforced
Ambient temperature-40 °C ... +40 °C (T6); -40 °C ... +55 °C (T5)-60 °C ... +40 °C (T6); -60 °C ... +55 °C (T5)—-50 °C ... +75 °C (-58 °F ... +167 °F)
CertificatesATEX, IECEx, NEPSI, PESO, KTL, ULB, DNVATEX, IECEx, NEPSI, PESO, KTL, ULB, DNVATEX, IECEx, NEPSIUL, ATEX, IECEx, PESO, NEPSI, KGS, ITRI, ULB, BVIS

Request a price and lead time

Series 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many conductors can be connected?

Up to 36, depending on size and current, with cross-sections of 1.5, 2.5, 4 or 6 mm².

Which enclosure sizes does the series offer?

Three design sizes, listed as 8118/112, 8118/114, 8118/122, 8118/124, 8118/132 and 8118/134.

What voltages are the boxes rated for?

690 V for Ex e, 550 V for Ex e with earth plate and 60 V for Ex i.