NEC/IEC Series 8146/1 Ex e Terminal Boxes, Polyester Resin, 690 V, IP66
Series 8146/1 Ex e terminal boxes to NEC/IEC come in eight basic sizes of various heights. Glass-fibre-reinforced polyester resin enclosure, IP66, 600 V (NEC, CEC) and 690 V (IEC), -50 °C to +75 °C.
- Type of protection
- Ex e
- Enclosure material
- Polyester resin, glass fibre reinforced
- Degree of protection (IP)
- IP66
- Rated operational voltage AC NEC, CEC
- 600 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Series 8146 terminal boxes are moulded from high-quality glass fibre reinforced polyester resin and suit harsh ambient conditions. With eight basic sizes in various heights they are universally usable. On request they are equipped with terminal blocks up to 300 mm², and a flange can be fitted on several enclosure sides as an option.
Protection is IP66. The enclosures have captive cover screws and can be equipped to customer requirements. The maximum number of terminals is 10 ... 26, depending on the version.
Rated operational voltage is 600 V AC for NEC and CEC and 690 V AC for IEC, with a maximum of 1100 V AC/DC. Current carrying capacity is up to 65 A under NEC and CEC and up to 54 A under IEC. Ambient temperature runs from -50 °C to +75 °C (-58 °F ... +167 °F).
The marking lists Class I, Div. 2, Groups A,B,C,D; Class I, Zone 1, AEx e IIC T6,T5,T4; Class II, Div. 2, Groups F,G; Class III; Ex eb IIC T6/T5/T4 Gb; and Ex tb IIIC T80 °C ... T95 °C ... T135 °C Db. NEC 500, 505, 506, CEC Section 18 and IEC/EN 60529 are referenced.
Certificates are UL, ATEX, IECEx, PESO, NEPSI, KGS, ITRI, ULB and BVIS. Weight is 2.34 to 6.11 lb. Example types are 8146/1051, 8146/1061 and 8146/1073.
Technical specifications
| Type of protection | Ex e |
|---|---|
| Enclosure material | Polyester resin, glass fibre reinforced |
| Degree of protection (IP) | IP66 |
| Rated operational voltage AC NEC, CEC | 600 V |
| Rated operational voltage AC IEC | 690 V |
| Rated operational voltage max. | 1100 V AC/DC |
| Current carrying capacity NEC, CEC | max. 65 A |
| Current carrying capacity IEC | max. 54 A |
| Max. no. of terminals | 10 ... 26 |
| Ambient temperature | -50 °C ... +75 °C (-58 °F ... +167 °F) |
| Marking (IEC) | Ex eb IIC T6/T5/T4 Gb; Ex tb IIIC T80 °C ... T95 °C ... T135 °C Db |
| Marking (NEC) | Class I, Zone 1, AEx e IIC T6,T5,T4; Class I, Div. 2, Groups A,B,C,D; Class II, Div. 2, Groups F,G; Class III |
| Standards | NEC 500; NEC 505; NEC 506; CEC Section 18; IEC/EN 60529 |
| Weight | 2.34 ... 6.11 lb |
Part numbers
Show all part numbers (3)
278800, 278802, 278803
How it compares with similar models
| Parameter | NEC/IEC Series 8146/1 Ex e Terminal Boxes, Polyester Resin, 690 V, IP66 | NEC/IEC Series 8146/2 Ex i Terminal Boxes, Ex ia ib IIC T6 Gb, 60 V, IP66 | NEC/IEC Series 8150 Ex e Terminal Boxes, Stainless Steel 1.4404, IP66, 690 V | NEC/IEC Series 8150 Ex i Terminal Boxes, Stainless Steel 1.4404, IP66, M8 Earth |
|---|---|---|---|---|
| Type of protection | Ex e | Ex i | Ex e | Ex i |
| Enclosure material | Polyester resin, glass fibre reinforced | Polyester resin, glass fibre reinforced | Stainless steel 1.4404 (AISI 316L), brush finished | Stainless steel 1.4404 (ANSI 316L), brush finished |
| Rated operational voltage AC IEC | 690 V | 60 V | 690 V | — |
| Max. no. of terminals | 10 ... 26 | 19; 27; 49; 51 | 9; 13 | 19; 27 |
| Standards | NEC 500; NEC 505; NEC 506; CEC Section 18; IEC/EN 60529 | NEC 500; NEC 505; NEC 506; CEC Section 18; IEC/EN 60529 | NEC 500; NEC 505; NEC 506; CE Code Section 18; IEC 60529 | NEC 500; NEC 505; NEC 506; CEC Section 18; IEC 60529 |
| Weight | 2.34 ... 6.11 lb | 2.2 ... 10.49 lb | 17.64 lb | 5.6 ... 14.7 lb |
Request a price and lead time
NEC/IEC Series 8146/1 Ex e Terminal Boxes, Polyester Resin, 690 V, IP66. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What voltage are the 8146/1 boxes rated for?
600 V AC under NEC and CEC and 690 V AC under IEC, with a maximum of 1100 V AC/DC.
Which terminals can be fitted?
Terminal blocks up to 300 mm², with a maximum of 10 ... 26 terminals depending on the version.
What is the IEC explosion protection marking?
Ex eb IIC T6/T5/T4 Gb and Ex tb IIIC T80 °C ... T95 °C ... T135 °C Db.