Series 8040 NEC® / CE Code explosion-protected control stations, IP66

Series 8040 control stations use explosion-protected components in a non-metallic enclosure of glass fibre reinforced polyester (FRP). They carry NEC®, CE Code, ATEX and IECEx certification, IP66, and work from -60 °C to 40 °C.

Rated operational voltage
AC 550 V
Rated operational current
10 A
Degree of protection IP (IEC 60529)
IP66
Enclosure type (UL50 & UL50E)
3, 4, 4X

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8040 NEC® / CE Code control stations combine explosion-protected components with a non-metallic enclosure. The enclosure is lightweight glass fibre reinforced polyester (FRP), well suited to corrosive atmospheres. The stations are certified four ways: NEC®, CE Code, ATEX and IECEx.

Stations can be fitted with pushbuttons, illuminated pushbuttons, control switches and LEDs. Large and small handles, twin pushbuttons and EM-STOP mushroom stay-put buttons are also in the range. Versions with other entries, contact options and additional certifications are made on request.

Rated operational voltage is AC 550 V and rated operational current is 10 A, with connection cross-section up to 2.5 mm². Protection is IP66, and the enclosure type to UL50 and UL50E is 3, 4, 4X. Ambient temperature runs from -60 °C to 40 °C (-76 °F ... +104 °F). The seal is foamed silicone, and the cover is held by captive M4 stainless steel screws. The entry is NPT 3/4, and a metal adaptor is possible.

Explosion protection is Ex db eb IIC T6 Gb, Ex tb IIIC 80 °C Db and Class I, Zone 1, AEx db eb IIC T6. Class I, Div. 2 covers Groups A, B, C, D, and Class II, III, Div. 2 covers Groups F, G. Standards are NEC® 500, 505, 506 and CE Code Section 18. Certificates include UL, ATEX (PTB), IECEx (PTB), PESO, KGS, NEPSI, ITRI and ULB, with DNV ship approval.

Technical specifications

Rated operational voltageAC 550 V
Rated operational current10 A
Degree of protection IP (IEC 60529)IP66
Enclosure type (UL50 & UL50E)3, 4, 4X
Enclosure materialPolyester resin, glass fibre reinforced (FRP)
SealSilicone, foamed
Cover fixingCaptive M4 stainless steel screws
Connection cross-section max.2.5 mm²
Ambient temperature-60 °C ... 40 °C (-76 °F ... +104 °F)
Entry typeNPT 3/4
Explosion protectionEx db eb IIC T6 Gb; Ex tb IIIC 80 °C Db; Class I, Zone 1, AEx db eb IIC T6
StandardsNEC® 500, NEC® 505, NEC® 506, CE Code Section 18

Part numbers

Show all part numbers (3)

8040/1395-C2462 (288552), 8040/11E8-C2494 (290554), 8040/12E8X-36I08SF05 (287030)

How it compares with similar models

ParameterSeries 8040 NEC® / CE Code explosion-protected control stations, IP66Series 8150 stainless steel 1.4404 (316L) control stations, explosion-protected, IP66Series 8150/5-V40 NEC® / CE Code control stations in 316L stainless steel, IP66TEF4500901 local control panel for IMT helideck lights, Ex db eb IIC T4 Gb, IP66
Rated operational current10 A6 A; UL 10 A6 A3 A
Enclosure materialPolyester resin, glass fibre reinforced (FRP)Stainless steel 1.4404 (AISI 316L), brush finishedStainless steel 1.4404 (AISI 316L)Stainless steel 1.4404 (AISI 316L), brush finished
Ambient temperature-60 °C ... 40 °C (-76 °F ... +104 °F)-50 °C ... +60 °C-50 °C ... +60 °C-20 °C ... +45 °C
Explosion protectionEx db eb IIC T6 Gb; Ex tb IIIC 80 °C Db; Class I, Zone 1, AEx db eb IIC T6Ex db eb IIC T6 Gb; Ex tb IIIC 80 °C DbEx db eb IIC T6 Gb; Ex tb IIIC 80 °C DbE II 2 G Ex db eb IIC T4 Gb; Zone 1, Zone 2

Request a price and lead time

Series 8040 NEC® / CE Code explosion-protected control stations, IP66. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which approvals do Series 8040 stations hold?

NEC®, CE Code, ATEX and IECEx, to NEC® 500, 505, 506 and CE Code Section 18.

Which control elements can be fitted?

Pushbuttons, illuminated pushbuttons, control switches, LEDs, handles and EM-STOP mushroom stay-put buttons.

What are the temperature range and protection degree?

Ambient temperature is -60 °C to 40 °C, protection is IP66, and the enclosure type is 3, 4, 4X to UL50 and UL50E.