6525/22 (Ex ec) LED floodlight, 100 ... 225 W, for Zone 2, stainless steel, IP66, IK10
The 6525/22 is an LED floodlight for Zone 2 with Ex ec protection, so the vapour tightness test does not apply. Power is 100, 160 or 225 W with 110 ... 277 V AC input, in a stainless steel enclosure with IP66, IK10 and an ambient range of -60 °C to +60 °C.
- Type
- 6525/22 (Ex ec) LED floodlight
- Type of protection
- Ex ec
- Lamp wattage
- 100 W; 160 W; 225 W
- AC rated operational voltage
- 110 ... 277 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The revised generation of LED floodlights for Zone 2 includes the 6525/22 with Ex ec type of protection, introduced especially for the European market. Because the floodlight is checked and approved to Ex ec, the time-consuming vapour tightness test is not applicable.
The wide-range input also meets electrical installation conditions for global use. An optional DALI interface leads towards a digital lighting solution, and DALI versions are offered for lighting control, monitoring and switching. The extremely low start-up current means circuit breakers that are already installed need not be replaced.
Power is 100 W, 160 W or 225 W with narrow, medium or wide beams at 5000 K and a colour rendering of ≥ 80. Luminous flux is 13400, 18800, 19250, 26400 or 26250 lm depending on the version. The input is 110 ... 277 V AC (optionally from 100 V) at 50 - 60 Hz.
A stainless steel enclosure of 1.4404 or 1.4301 is standard and gives long service life under harsh ambient conditions. Protection is IP66 and impact strength is IK10. Ambient temperature runs from -60 °C to +60 °C. Terminals take up to 6 mm² solid, and drilled holes are 3 x M20 and 3 x M25. Dimensions are 445 x 400 x 84 mm and weight is 15 kg ... 18.5 kg. The documented standards include NEC 500, NEC 505, NEC 506, CE Code Section 18 and IEC 62262.
Technical specifications
| Type | 6525/22 (Ex ec) LED floodlight |
|---|---|
| Type of protection | Ex ec |
| Lamp wattage | 100 W; 160 W; 225 W |
| AC rated operational voltage | 110 ... 277 V |
| Frequency range | 50 - 60 Hz |
| Luminous flux | 13400; 18800; 19250; 26400; 26250 lm |
| Light distribution | Narrow-beam, medium-beam, wide beam |
| Colour temperature | 5000 K |
| Colour rendering | ≥ 80 |
| Degree of protection (IP) | IP66 |
| Impact strength (IEC 62262) | IK10 |
| Enclosure material | Stainless steel 1.4404; 1.4301 |
| Ambient temperature | -60 °C ... +60 °C |
| Drilled holes | 3 x M20; 3 x M25 |
| Max. solid connection terminals | 6 mm² |
| Dimensions | 445 x 400 x 84 mm |
| Weight | 15 kg ... 18.5 kg |
Part numbers
Show all part numbers (6)
282367, 284537, 284538, 284539, 284540, 291165
How it compares with similar models
| Parameter | 6525/22 (Ex ec) LED floodlight, 100 ... 225 W, for Zone 2, stainless steel, IP66, IK10 | 6525/21 (Ex nR) LED floodlight, 100 ... 225 W, for Zones 2, 21, 22, stainless steel, IP66, IK10 | 6125/2 LED floodlight, 100 ... 225 W, for Zone 1, stainless steel, IP66, IK10 | 6036/1 compact tubular LED light fitting, Ex d, IP66/IP68, IK10 |
|---|---|---|---|---|
| Type | 6525/22 (Ex ec) LED floodlight | 6525/21 (Ex nR) LED floodlight | 6125/2 LED floodlight | 6036/1 compact tubular LED light fitting |
| Lamp wattage | 100 W; 160 W; 225 W | 100 W; 160 W; 225 W | 100 W; 160 W; 225 W | 13 W, 16 W, 25 W, 48 W |
| AC rated operational voltage | 110 ... 277 V | 110 ... 277 V | 110 ... 277 V, 50/60 Hz | 24 ... 48 V; 110 ... 240 V; 220 ... 240 V |
| Luminous flux | 13400; 18800; 19250; 26400; 26250 lm | — | from 12350 lm | from 338 lm |
| Colour temperature | 5000 K | 5700 K | 4000 K; 5000 K; 5700 K | — |
| Colour rendering | ≥ 80 | ≥ 70 | ≥ 80 (warm, neutral); ≥ 70 (cool) | — |
Request a price and lead time
6525/22 (Ex ec) LED floodlight, 100 ... 225 W, for Zone 2, stainless steel, IP66, IK10. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does Ex ec protection mean for this floodlight?
It is checked and approved to Ex ec, so the vapour tightness test is not applicable.
What ambient temperature range applies?
From -60 °C to +60 °C.
Which supply voltage and power ratings are offered?
110 ... 277 V AC at 50 - 60 Hz, with 100 W, 160 W and 225 W.