C-LUX 6109 compact emergency LED luminaire, Ex db eb ib op is IIC T4 Gb
The C-LUX 6109 compact emergency luminaires serve as emergency lighting and as indication or escape route luminaires. Luminous flux is 775 lm at most, emergency operating time is 1.5 or 3 h, supply is 100 ... 240 V AC, protection is IP66/IP67 and the Zones are 1, 2, 21 and 22.
- Type
- C-LUX 6109 compact emergency LED luminaire
- Zone
- 1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)
- Explosion protection (gas)
- Ex db eb ib op is IIC T4 Gb
- Explosion protection (dust)
- Ex tb op is IIIC T100 °C Db
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
C-LUX 6109 compact emergency luminaires provide emergency lighting and can also be used as indication luminaires or escape route luminaires. They mount on a wall, on a ceiling or suspended. They are certified to ATEX, IECEx and Polen (CNBOP) for Zone 1 (2 G, Gb), Zone 2 (3 G, Gc), Zone 21 (2 D, Db) and Zone 22 (3 D, Dc).
Operating modes are continuous mode and continuous mode with switchable emergency lighting. Optional DALI technology adds a function test and a rated operating time test. The recognition range is d ≥ 30 m, and emergency exit signs use a suspended panel that can be read from both sides. The design is lightweight and compact.
The light source is an LED at 5000 K with a luminous flux of up to 775 lm. Light distribution is 0 ... 60° with deflection optics, 2 x 15° without a light attachment and 80° with a diffuser. Emergency light output is 25 % for 3.0 h or 50 % for 1.5 h. The battery is a gas-tight NiCd type of 2.2 Ah, with an operating time of 1.5 / 3 h.
Electrically the luminaire takes 100 ... 240 V AC at 50 - 60 Hz, is Class I and has terminals up to 6 mm² solid and 4 mm² finely stranded, with loop in/loop out through wiring. Drilled holes are 2 x M25 or 3 x M25, with cable entries 2 x M25 for Ø 7 ... 17 mm. Explosion protection is Ex db eb ib op is IIC T4 Gb for gas and Ex tb op is IIIC T100 °C Db for dust.
The enclosure is light grey thermoset (RAL 7035) with a polycarbonate cover and silicone seal. Protection is IP66/IP67 with IK08 impact strength. Ambient temperature is -30°C ... +50°C or -30°C ... +60°C. Dimensions are 440.30 x 190.60 x 87.50 mm with the escape sign and 425 x 190.60 x 111.10 mm without it; weight is 3.3 kg ... 4.0 kg.
Technical specifications
| Type | C-LUX 6109 compact emergency LED luminaire |
|---|---|
| Zone | 1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc) |
| Explosion protection (gas) | Ex db eb ib op is IIC T4 Gb |
| Explosion protection (dust) | Ex tb op is IIIC T100 °C Db |
| Colour temperature | 5000 K |
| Luminous flux | до 775 lm |
| Emergency light output | 25 % - 3.0 h; 50 % - 1.5 h |
| Battery | NiCd, gas-tight, 2.2 Ah |
| Operating time | 1.5 / 3 h |
| AC operating voltage | 100 ... 240 V, 50 - 60 Hz |
| Control interface | Without; DALI |
| IP degree of protection (IEC 60598) | IP66/IP67 |
| Impact strength (IEC 62262) | IK08 |
| Class | I |
| Enclosure material | Thermoset |
| Ambient temperature | -30°C ... +50°C; -30°C ... +60°C |
| Drilled holes | 2 x M25; 3 x M25 |
| Weight | 3.3 kg ... 4.0 kg |
Part numbers
Show all part numbers (3)
287804, 287820, 287800
How it compares with similar models
| Parameter | C-LUX 6109 compact emergency LED luminaire, Ex db eb ib op is IIC T4 Gb | EXLUX 6009/4 emergency LED luminaire with integrated battery, Zones 1, 2, 21, 22 | EXLUX L409/4 industrial emergency LED luminaire with central lock | EXLUX 6409/4 emergency LED luminaire with integrated battery, Zones 2, 21, 22 |
|---|---|---|---|---|
| Type | C-LUX 6109 compact emergency LED luminaire | EXLUX 6009/4 emergency LED luminaire | EXLUX L409/4 emergency LED luminaire | EXLUX 6409/4 emergency LED luminaire |
| Zone | 1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc) | 1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc) | — | 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc) |
| Colour temperature | 5000 K | 4000 K, 5000 K, 6500 K | 5000 K | — |
| Luminous flux | до 775 lm | 2910 lm; 5810 lm | — | 2910 lm; 5810 lm |
| Emergency light output | 25 % - 3.0 h; 50 % - 1.5 h | 35 % - 3.0 h; 65 % - 1.5 h; 20 % - 3.0 h; 35 % - 1.5 h | 65 % - 1.5 h; 35 % - 1.5 h | 35 % - 3.0 h; 65 % - 1.5 h; 20 % - 3.0 h; 35 % - 1.5 h |
| Operating time | 1.5 / 3 h | 1.5 / 3 h | — | 1.5 h; 3 h |
Request a price and lead time
C-LUX 6109 compact emergency LED luminaire, Ex db eb ib op is IIC T4 Gb. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How long does the luminaire run in emergency mode?
For 1.5 or 3 h: emergency light output is 25 % for 3.0 h or 50 % for 1.5 h.
What explosion protection marking does it have?
Ex db eb ib op is IIC T4 Gb for gas and Ex tb op is IIIC T100 °C Db for dust.
Is DALI available and which operating modes exist?
DALI is optional and adds function and rated operating time tests. Modes are continuous and continuous with switchable emergency lighting.