International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

C-LUX 6109 compact emergency LED luminaire, Ex db eb ib op is IIC T4 Gb

The C-LUX 6109 compact emergency luminaires serve as emergency lighting and as indication or escape route luminaires. Luminous flux is 775 lm at most, emergency operating time is 1.5 or 3 h, supply is 100 ... 240 V AC, protection is IP66/IP67 and the Zones are 1, 2, 21 and 22.

Type
C-LUX 6109 compact emergency LED luminaire
Zone
1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)
Explosion protection (gas)
Ex db eb ib op is IIC T4 Gb
Explosion protection (dust)
Ex tb op is IIIC T100 °C Db

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

C-LUX 6109 compact emergency luminaires provide emergency lighting and can also be used as indication luminaires or escape route luminaires. They mount on a wall, on a ceiling or suspended. They are certified to ATEX, IECEx and Polen (CNBOP) for Zone 1 (2 G, Gb), Zone 2 (3 G, Gc), Zone 21 (2 D, Db) and Zone 22 (3 D, Dc).

Operating modes are continuous mode and continuous mode with switchable emergency lighting. Optional DALI technology adds a function test and a rated operating time test. The recognition range is d ≥ 30 m, and emergency exit signs use a suspended panel that can be read from both sides. The design is lightweight and compact.

The light source is an LED at 5000 K with a luminous flux of up to 775 lm. Light distribution is 0 ... 60° with deflection optics, 2 x 15° without a light attachment and 80° with a diffuser. Emergency light output is 25 % for 3.0 h or 50 % for 1.5 h. The battery is a gas-tight NiCd type of 2.2 Ah, with an operating time of 1.5 / 3 h.

Electrically the luminaire takes 100 ... 240 V AC at 50 - 60 Hz, is Class I and has terminals up to 6 mm² solid and 4 mm² finely stranded, with loop in/loop out through wiring. Drilled holes are 2 x M25 or 3 x M25, with cable entries 2 x M25 for Ø 7 ... 17 mm. Explosion protection is Ex db eb ib op is IIC T4 Gb for gas and Ex tb op is IIIC T100 °C Db for dust.

The enclosure is light grey thermoset (RAL 7035) with a polycarbonate cover and silicone seal. Protection is IP66/IP67 with IK08 impact strength. Ambient temperature is -30°C ... +50°C or -30°C ... +60°C. Dimensions are 440.30 x 190.60 x 87.50 mm with the escape sign and 425 x 190.60 x 111.10 mm without it; weight is 3.3 kg ... 4.0 kg.

Technical specifications

TypeC-LUX 6109 compact emergency LED luminaire
Zone1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)
Explosion protection (gas)Ex db eb ib op is IIC T4 Gb
Explosion protection (dust)Ex tb op is IIIC T100 °C Db
Colour temperature5000 K
Luminous fluxдо 775 lm
Emergency light output25 % - 3.0 h; 50 % - 1.5 h
BatteryNiCd, gas-tight, 2.2 Ah
Operating time1.5 / 3 h
AC operating voltage100 ... 240 V, 50 - 60 Hz
Control interfaceWithout; DALI
IP degree of protection (IEC 60598)IP66/IP67
Impact strength (IEC 62262)IK08
ClassI
Enclosure materialThermoset
Ambient temperature-30°C ... +50°C; -30°C ... +60°C
Drilled holes2 x M25; 3 x M25
Weight3.3 kg ... 4.0 kg

Part numbers

Show all part numbers (3)

287804, 287820, 287800

How it compares with similar models

ParameterC-LUX 6109 compact emergency LED luminaire, Ex db eb ib op is IIC T4 GbEXLUX 6009/4 emergency LED luminaire with integrated battery, Zones 1, 2, 21, 22EXLUX L409/4 industrial emergency LED luminaire with central lockEXLUX 6409/4 emergency LED luminaire with integrated battery, Zones 2, 21, 22
TypeC-LUX 6109 compact emergency LED luminaireEXLUX 6009/4 emergency LED luminaireEXLUX L409/4 emergency LED luminaireEXLUX 6409/4 emergency LED luminaire
Zone1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)—2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)
Colour temperature5000 K4000 K, 5000 K, 6500 K5000 K—
Luminous fluxдо 775 lm2910 lm; 5810 lm—2910 lm; 5810 lm
Emergency light output25 % - 3.0 h; 50 % - 1.5 h35 % - 3.0 h; 65 % - 1.5 h; 20 % - 3.0 h; 35 % - 1.5 h65 % - 1.5 h; 35 % - 1.5 h35 % - 3.0 h; 65 % - 1.5 h; 20 % - 3.0 h; 35 % - 1.5 h
Operating time1.5 / 3 h1.5 / 3 h—1.5 h; 3 h

Request a price and lead time

C-LUX 6109 compact emergency LED luminaire, Ex db eb ib op is IIC T4 Gb. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How long does the luminaire run in emergency mode?

For 1.5 or 3 h: emergency light output is 25 % for 3.0 h or 50 % for 1.5 h.

What explosion protection marking does it have?

Ex db eb ib op is IIC T4 Gb for gas and Ex tb op is IIIC T100 °C Db for dust.

Is DALI available and which operating modes exist?

DALI is optional and adds function and rated operating time tests. Modes are continuous and continuous with switchable emergency lighting.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH