International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

EXLUX 6409/4 emergency LED luminaire with integrated battery, Zones 2, 21, 22

The EXLUX Series 6409/4 is an emergency LED luminaire with an integrated battery for Zones 2, 21 and 22. Size 2 is 25 W and 2910 lm, size 4 is 45 W and 5810 lm. Emergency lighting lasts 90 or 180 minutes, and a weekly function test runs automatically.

Type
EXLUX 6409/4 emergency LED luminaire
Zone
2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)
Lamp
LED, 1 lamp
Lamp wattage
25 W (size 2); 45 W (size 4)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The 6409/4 emergency luminaire of the EXLUX range combines LED lighting with an integrated battery. It can be installed in stand-by switching, continuous mode or switchable stand-by switching. It is intended for Zone 2 (3 G, Gc), Zone 21 (2 D, Db) and Zone 22 (3 D, Dc), with ATEX and IECEx certificates.

A weekly function test and an annual rated operating time test are carried out automatically, and an LED shows the result. Versions with 90 minutes or 180 minutes of emergency lighting (1.5 h and 3 h) are available. After 100000 h the luminous flux is still 90 % of the starting value. DALI for control and monitoring is optional.

Size 2 is 25 W with 2910 lm at 116 lm/W, and size 4 is 45 W with 5810 lm at 129 lm/W. Distribution is 120°x120° through a diffusing glass, at 4000 K or 5000 K. Emergency light output is 35 % for 3.0 h or 65 % for 1.5 h, with 20 % for 3.0 h and 35 % for 1.5 h in some versions.

The supply is 110 ... 240 V AC at 50 - 60 Hz. The enclosure is polyester resin with a diffuser. Disconnection of the luminaire is all-pole or battery only. Through wiring is 6 or 8 conductors at 2.5 mm², or none. Drilled holes are 2 x M25, 3 x M20, 3 x M25 and 4 x M20, with cable entries 2 x M25 for Ø 7 ... 17 mm that can be ordered as an accessory. Weight is 4.7 kg, 5.4 kg or 8.1 kg depending on the version.

Technical specifications

TypeEXLUX 6409/4 emergency LED luminaire
Zone2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)
LampLED, 1 lamp
Lamp wattage25 W (size 2); 45 W (size 4)
Luminous flux2910 lm; 5810 lm
Luminaire efficacy116 lm/W; 129 lm/W
Light colour4000 K, 5000 K
Light distribution120°x120° with diffusing glass
Emergency light output35 % - 3.0 h; 65 % - 1.5 h; 20 % - 3.0 h; 35 % - 1.5 h
Operating time1.5 h; 3 h
Rated operational voltage AC110 ... 240 V, 50 - 60 Hz
Enclosure materialPolyester resin
Disconnection of the luminaireAll-pole disconnection; only battery
Through wiring6 or 8 conductors 2.5 mm²; without
Drilled holes2 x M25; 3 x M20; 3 x M25; 4 x M20
Weight4.7 kg; 5.4 kg; 8.1 kg

Part numbers

Show all part numbers (6)

277319, 271004, 271816, 267859, 267860, 271825

How it compares with similar models

ParameterEXLUX 6409/4 emergency LED luminaire with integrated battery, Zones 2, 21, 22EXLUX 6009/4 emergency LED luminaire with integrated battery, Zones 1, 2, 21, 22EXLUX L409/4 industrial emergency LED luminaire with central lockEXLUX 6402/4 linear LED luminaire for Zones 2 and 22, IP66/IP67
TypeEXLUX 6409/4 emergency LED luminaireEXLUX 6009/4 emergency LED luminaireEXLUX L409/4 emergency LED luminaireEXLUX 6402/4 linear LED luminaire
Zone2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)—2 (3 G, Gc); 22 (3 D, Dc); some versions 21 (2 D, Db)
Lamp wattage25 W (size 2); 45 W (size 4)25 W (size 2); 45 W (size 4)—18 W, 22 W, 42 W
Luminous flux2910 lm; 5810 lm2910 lm; 5810 lm—2550 lm, 2800 lm, 2890 lm, 5100 lm
Luminaire efficacy116 lm/W; 129 lm/W116 lm/W; 129 lm/W—116 lm/W, 152 lm/W, 157 lm/W, 121 lm/W
Light distribution120°x120° with diffusing glass120°x120° with diffusing glass120°x120° with diffusing glass120°x120°

Request a price and lead time

EXLUX 6409/4 emergency LED luminaire with integrated battery, Zones 2, 21, 22. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How long does emergency lighting last?

Versions with 90 minutes and with 180 minutes exist, that is 1.5 h and 3 h.

Which zones is the luminaire intended for?

Zone 2 (3 G, Gc), Zone 21 (2 D, Db) and Zone 22 (3 D, Dc).

Which disconnection and through wiring options exist?

All-pole or battery-only disconnection, and through wiring of 6 or 8 conductors at 2.5 mm² or none.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides