Series 8146/5-V37 safety switches, 10–180 A, AC-3, up to 690 V, polyester enclosure
Series 8146/5-V37 safety switches disconnect machines and system parts from the energy supply for cleaning and repair. Ratings run from 10 A to 180 A at 400, 500 and 690 V with AC-3 capacity, in a polyester resin enclosure for Zones 1/2/21/22.
- Series
- 8146/5-V37
- Installation zones
- 1, 2, 21, 22
- Rated operational current
- 10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A, 180 A
- AC rated operational voltage
- 400 V, 500 V, 690 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Series 8146/5-V37 safety switches disconnect machines and system parts from the energy supply for cleaning and repair, as prescribed. All of the installed load disconnect switches have AC-3 switching capacity. The rotary actuator can be locked in the 0-position with three padlocks, and the cover can only be removed in the I-position.
Rated operational currents are 10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A and 180 A, at 400 V, 500 V or 690 V AC and 50 - 60 Hz. A single rotary actuator operates the main and auxiliary contacts, and a leading auxiliary contact of ≥ 20 ms gives safe disconnection. The switch works with conventional and variable-frequency drives and is designed to IEC/EN 62626-1, class 1.
As an example of AC-3 capacity, the 10 A, 690 V version is rated 2.2 kW at 230 V, 4 kW at 400 V and 440 V, 5.50 kW at 500 V and 7.50 kW at 690 V. Versions are 3-pole, 6-pole and 3-pole + N, with a black shroud and handle or a yellow shroud and red handle. N-terminal, PTC resistor terminal and main-contact-on-terminals versions exist, with auxiliary contacts 1 NC and 1 NO/delayed.
The enclosure is polyester resin. Ambient temperature is -40 °C to +40 °C, rising to +60 °C for some versions. Entries are 2 x M25 (Ø 7 ... 17 mm) and 1 x M20 (Ø 4 ... 13 mm), or a drilled brass plate. Certificates are ATEX (PTB), IECEx (PTB), India (PESO), China (NEPSI), Korea (KTL) and Korea (KGS), for Zones 1, 2, 21 and 22.
Technical specifications
| Series | 8146/5-V37 |
|---|---|
| Installation zones | 1, 2, 21, 22 |
| Rated operational current | 10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A, 180 A |
| AC rated operational voltage | 400 V, 500 V, 690 V |
| Frequency range | 50 - 60 Hz |
| Switching capacity | AC-3 |
| Number of poles | 3-pole, 6-pole, 3-pole + N |
| Auxiliary contact | leading ≥ 20 ms; 1 NC, 1 NO |
| Handle colour | black shroud and handle; yellow shroud, red handle |
| Locking | in the 0-position with three padlocks |
| Enclosure material | polyester resin |
| Ambient temperature | -40 °C ... +40 °C up to +60 °C |
| Standards | IEC/EN 62626-1, class 1 |
| Certificates | ATEX (PTB), IECEx (PTB), India (PESO), China (NEPSI), Korea (KTL), Korea (KGS) |
Part numbers
Show all part numbers (15)
147855, 220277, 200558, 213395, 222088, 201405, 147858, 226355, 213476, 213479, 200559, 200208, 200207, 226356, 226354
How it compares with similar models
| Parameter | Series 8146/5-V37 safety switches, 10–180 A, AC-3, up to 690 V, polyester enclosure | Series 8150/5-V37 stainless steel safety switches, 16–125 A, 690 V, Ex db eb IIC T6 Gb | Series 8537 safety switch, 250 A, 690 V / 500 V, Ex db eb IIC T5 Gb, IP65 | Series 8146/5-V11 load disconnect switches, 10–80 A, 3-pole, 6-pole and 3-pole + N |
|---|---|---|---|---|
| Rated operational current | 10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A, 180 A | 16 A, 25 A, 40 A, 63 A, 125 A | 250 A | 10 - 80 A (16 - 630 A possible) |
| Number of poles | 3-pole, 6-pole, 3-pole + N | 3-pole | 3-pole | 3-pole, 6-pole, 3-pole + N |
| Auxiliary contact | leading ≥ 20 ms; 1 NC, 1 NO | without NC, 1 NC; 1 NO/delayed | 1 NO/delayed | leading ≥ 20 ms |
| Handle colour | black shroud and handle; yellow shroud, red handle | black shroud and handle; yellow shroud, red handle | — | black, red |
| Enclosure material | polyester resin | stainless steel 1.4404 | sheet steel, painted | — |
| Ambient temperature | -40 °C ... +40 °C up to +60 °C | -40 °C to +50 °C | -20 °C ... +40 °C | -40 °C ... +40 °C up to +55 °C |
Request a price and lead time
Series 8146/5-V37 safety switches, 10–180 A, AC-3, up to 690 V, polyester enclosure. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What are the 8146/5-V37 safety switches for?
They disconnect machines and system parts from the energy supply for cleaning and repair.
How is the switch locked?
The rotary actuator locks in the 0-position with three padlocks, and the cover can only be removed in the I-position.
Is the switch suitable for variable-frequency drives?
Yes. The leading auxiliary contact of ≥ 20 ms disconnects the drive safely.