International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Series 8146/5-V37 safety switches, 10–180 A, AC-3, up to 690 V, polyester enclosure

Series 8146/5-V37 safety switches disconnect machines and system parts from the energy supply for cleaning and repair. Ratings run from 10 A to 180 A at 400, 500 and 690 V with AC-3 capacity, in a polyester resin enclosure for Zones 1/2/21/22.

Series
8146/5-V37
Installation zones
1, 2, 21, 22
Rated operational current
10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A, 180 A
AC rated operational voltage
400 V, 500 V, 690 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8146/5-V37 safety switches disconnect machines and system parts from the energy supply for cleaning and repair, as prescribed. All of the installed load disconnect switches have AC-3 switching capacity. The rotary actuator can be locked in the 0-position with three padlocks, and the cover can only be removed in the I-position.

Rated operational currents are 10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A and 180 A, at 400 V, 500 V or 690 V AC and 50 - 60 Hz. A single rotary actuator operates the main and auxiliary contacts, and a leading auxiliary contact of ≥ 20 ms gives safe disconnection. The switch works with conventional and variable-frequency drives and is designed to IEC/EN 62626-1, class 1.

As an example of AC-3 capacity, the 10 A, 690 V version is rated 2.2 kW at 230 V, 4 kW at 400 V and 440 V, 5.50 kW at 500 V and 7.50 kW at 690 V. Versions are 3-pole, 6-pole and 3-pole + N, with a black shroud and handle or a yellow shroud and red handle. N-terminal, PTC resistor terminal and main-contact-on-terminals versions exist, with auxiliary contacts 1 NC and 1 NO/delayed.

The enclosure is polyester resin. Ambient temperature is -40 °C to +40 °C, rising to +60 °C for some versions. Entries are 2 x M25 (Ø 7 ... 17 mm) and 1 x M20 (Ø 4 ... 13 mm), or a drilled brass plate. Certificates are ATEX (PTB), IECEx (PTB), India (PESO), China (NEPSI), Korea (KTL) and Korea (KGS), for Zones 1, 2, 21 and 22.

Technical specifications

Series8146/5-V37
Installation zones1, 2, 21, 22
Rated operational current10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A, 180 A
AC rated operational voltage400 V, 500 V, 690 V
Frequency range50 - 60 Hz
Switching capacityAC-3
Number of poles3-pole, 6-pole, 3-pole + N
Auxiliary contactleading ≥ 20 ms; 1 NC, 1 NO
Handle colourblack shroud and handle; yellow shroud, red handle
Lockingin the 0-position with three padlocks
Enclosure materialpolyester resin
Ambient temperature-40 °C ... +40 °C up to +60 °C
StandardsIEC/EN 62626-1, class 1
CertificatesATEX (PTB), IECEx (PTB), India (PESO), China (NEPSI), Korea (KTL), Korea (KGS)

Part numbers

Show all part numbers (15)

147855, 220277, 200558, 213395, 222088, 201405, 147858, 226355, 213476, 213479, 200559, 200208, 200207, 226356, 226354

How it compares with similar models

ParameterSeries 8146/5-V37 safety switches, 10–180 A, AC-3, up to 690 V, polyester enclosureSeries 8150/5-V37 stainless steel safety switches, 16–125 A, 690 V, Ex db eb IIC T6 GbSeries 8537 safety switch, 250 A, 690 V / 500 V, Ex db eb IIC T5 Gb, IP65Series 8146/5-V11 load disconnect switches, 10–80 A, 3-pole, 6-pole and 3-pole + N
Rated operational current10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A, 180 A16 A, 25 A, 40 A, 63 A, 125 A250 A10 - 80 A (16 - 630 A possible)
Number of poles3-pole, 6-pole, 3-pole + N3-pole3-pole3-pole, 6-pole, 3-pole + N
Auxiliary contactleading ≥ 20 ms; 1 NC, 1 NOwithout NC, 1 NC; 1 NO/delayed1 NO/delayedleading ≥ 20 ms
Handle colourblack shroud and handle; yellow shroud, red handleblack shroud and handle; yellow shroud, red handle—black, red
Enclosure materialpolyester resinstainless steel 1.4404sheet steel, painted—
Ambient temperature-40 °C ... +40 °C up to +60 °C-40 °C to +50 °C-20 °C ... +40 °C-40 °C ... +40 °C up to +55 °C

Request a price and lead time

Series 8146/5-V37 safety switches, 10–180 A, AC-3, up to 690 V, polyester enclosure. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What are the 8146/5-V37 safety switches for?

They disconnect machines and system parts from the energy supply for cleaning and repair.

How is the switch locked?

The rotary actuator locks in the 0-position with three padlocks, and the cover can only be removed in the I-position.

Is the switch suitable for variable-frequency drives?

Yes. The leading auxiliary contact of ≥ 20 ms disconnects the drive safely.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides