Series 8146/5-V11 load disconnect switches, 10–80 A, 3-pole, 6-pole and 3-pole + N

Series 8146/5-V11 load disconnect switches serve as mains connection switches for distributor systems and motor circuits. Standard versions go up to 80 A, in 3-pole, 6-pole or 3-pole + N form, with AC-3, AC-23 and DC-23 motor switching capacity, for Zones 1, 2, 21 and 22.

Series
8146/5-V11
Installation zones
1, 2, 21, 22
Rated operational current
10 - 80 A (16 - 630 A possible)
Rated operational voltage
AC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8146/5-V11 load disconnect switches are used as mains connection switches in distributor systems and motor circuits. The standard versions are rated up to 80 A, and currents from 16 to 630 A are possible. Motor switching capacity is AC-3, AC-23 and DC-23.

A large rotary actuator, black or red/yellow, can be padlocked. One actuator operates both the main and the auxiliary contacts, and a leading auxiliary contact of ≥ 20 ms disconnects a frequency converter safely, so the switch works with conventional drives and with variable-frequency drives. The main contacts have positive opening operation.

The range includes rated currents of 10, 16, 20, 25, 40 and 63 - 80 A, 3-pole, 6-pole and 3-pole + N versions, and reversing switches. The rated voltage is AC. Cable glands range from 1 x M32 (Ø 9 ... 21 mm) up to 4 x M50 (Ø 16 ... 35 mm); M25 (Ø 7 ... 17 mm) and M40 (Ø 12 ... 28 mm) also occur.

The switches are suitable for Zones 1, 2, 21 and 22. Minimum ambient temperature is -40 °C and the maximum is +40 °C, rising to +55 °C depending on the version. The selection table lists IP20. The design relates to IEC/EN 60079-7, -14, -17 and -19, with certificates ATEX (PTB), IECEx (PTB), India (PESO), China (NEPSI) and the CE mark.

Technical specifications

Series8146/5-V11
Installation zones1, 2, 21, 22
Rated operational current10 - 80 A (16 - 630 A possible)
Rated operational voltageAC
Motor switching capacityAC-3, AC-23 and DC-23
Number of poles3-pole, 6-pole, 3-pole + N
Handle colourblack, red
Auxiliary contactleading ≥ 20 ms
Ambient temperature-40 °C ... +40 °C up to +55 °C
Cable gland1x M32 Ø 9 ... 21 mm to 4x M50 Ø 16 ... 35 mm
IP ratingIP20
StandardsIEC/EN 60079-7, -14, -17, -19
CertificatesATEX (PTB), IECEx (PTB), India (PESO), China (NEPSI), CE

Part numbers

Show all part numbers (14)

221684, 221681, 221560, 221552, 221518, 221515, 221512, 221389, 221388, 221387, 221386, 221385, 221384, 221211

How it compares with similar models

ParameterSeries 8146/5-V11 load disconnect switches, 10–80 A, 3-pole, 6-pole and 3-pole + NSeries 8146/5-V37 safety switches, 10–180 A, AC-3, up to 690 V, polyester enclosureSeries 8150/5-V37 stainless steel safety switches, 16–125 A, 690 V, Ex db eb IIC T6 GbSeries 8146/5-V11 load disconnect and manual transfer switches, 15–150 A, up to 600 V AC / 240 V DC
Rated operational current10 - 80 A (16 - 630 A possible)10 A, 12 A, 16 A, 20 A, 25 A, 40 A, 63 A, 80 A, 125 A, 180 A16 A, 25 A, 40 A, 63 A, 125 A15 - 150 A
Number of poles3-pole, 6-pole, 3-pole + N3-pole, 6-pole, 3-pole + N3-pole1-pole, 2-pole, 3-pole, 3-pole + N
Handle colourblack, redblack shroud and handle; yellow shroud, red handleblack shroud and handle; yellow shroud, red handle—
Auxiliary contactleading ≥ 20 msleading ≥ 20 ms; 1 NC, 1 NOwithout NC, 1 NC; 1 NO/delayed—
Ambient temperature-40 °C ... +40 °C up to +55 °C-40 °C ... +40 °C up to +60 °C-40 °C to +50 °C-50 °C ... +55 °C
StandardsIEC/EN 60079-7, -14, -17, -19IEC/EN 62626-1, class 1IEC/EN 62626-1, class 1—

Request a price and lead time

Series 8146/5-V11 load disconnect switches, 10–80 A, 3-pole, 6-pole and 3-pole + N. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which current ratings does Series 8146/5-V11 offer?

Standard versions go up to 80 A (10, 16, 20, 25, 40 and 63 - 80 A); currents from 16 to 630 A are possible.

Can the switch be used with a frequency converter?

Yes. The leading auxiliary contact of ≥ 20 ms disconnects the converter safely, and one actuator operates the main and auxiliary contacts.

What pole configurations exist?

3-pole, 6-pole and 3-pole + N, plus reversing switch versions.