International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Ex d terminal and junction boxes, EJB, EJBX, GUB and GUBX series

Ex d (flameproof) and Ex tb (dust protection by enclosure) terminal and junction boxes for Zone 1, 2, 21 and 22. EJB and GUB are aluminium, EJBX and GUBX stainless steel.

Series
EJB, EJBX, GUB, GUBX
Type of protection
Ex d, Ex tb
Enclosure material
EJB, GUB: copper-free aluminium; EJBX, GUBX: stainless steel
Installation zones
Zone 1, 2, 21, 22

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Four series of Ex d (flameproof) and Ex tb (dust protection by enclosure) terminal and junction boxes cover signal and power distribution in explosion-hazardous areas. They are certified to global standards such as ATEX, IECEx and UL. The enclosures are made of copper-free aluminium or stainless steel, with corrosion resistance and high impact resistance, and suit oil and gas installations, offshore and marine environments, chemical plants and hygiene-critical locations.

EJB (aluminium) and EJBX (stainless steel) are installed in Zone 1, 2, 21 and 22 and in Class I, Class II, Division 1, and are suitable for gas group IIB+H2. They meet IP66 (IP66/67 with O-ring) and NEMA Types 4, 4X, 7 and 9. GUB (aluminium) covers the same zones and Class I, Class II, Division 1 for gas group IIC, with ratings up to IP66 (IP66/67 with O-ring) and NEMA Type 4X. GUBX (stainless steel) is installed in Zone 1, 2, 21 and 22 for gas group IIC, with ratings up to IP66 (IP66/67 with an additional O-ring).

All four series operate at ambient temperatures down to −60 °C. Each box can be configured with the enclosure size, the type and quantity of terminals, cable entries and cable glands. Where the terminal space must be visible, a viewing window of tempered, heat-resistant glass can be built into the enclosure.

The modular design simplifies installation and maintenance and lets the box be configured to specific technical and environmental needs.

Technical specifications

SeriesEJB, EJBX, GUB, GUBX
Type of protectionEx d, Ex tb
Enclosure materialEJB, GUB: copper-free aluminium; EJBX, GUBX: stainless steel
Installation zonesZone 1, 2, 21, 22
Classes and divisions (EJB, EJBX, GUB)Class I, Class II, Division 1
Gas group, EJB and EJBXIIB+H2
Gas group, GUB and GUBXIIC
Ingress protectionIP66 (IP66/67 with O-ring)
NEMA, EJB and EJBXType 4, 4X, 7, 9
NEMA, GUBType 4X
Ambient temperaturedown to −60 °C
Viewing windowsoptional, tempered heat-resistant glass
CertificationATEX, IECEx, UL

How it compares with similar models

ParameterEx d terminal and junction boxes, EJB, EJBX, GUB and GUBX seriesEx d control stations, EJB and EJBX series, aluminium and stainless steel enclosuresEx e, Ex ia and Ex tb terminal and junction boxes with Ex op pr splice boxes, GR and SR seriesEx e control stations, GR and SR series, in GRP and stainless steel enclosures
Type of protectionEx d, Ex tbEx d, Ex tb—Ex e
Enclosure materialEJB, GUB: copper-free aluminium; EJBX, GUBX: stainless steelEJB: copper-free aluminium; EJBX: stainless steelGR: GRP; SR: stainless steelGR: carbon-loaded GRP; SR: brushed AISI 316L stainless steel
Ingress protectionIP66 (IP66/67 with O-ring)IP66 (IP66/67 with additional O-ring)IP66, NEMA Type 4X—
CertificationATEX, IECEx, ULATEX, IECEx, NECATEX, IECEx, NECATEX, IECEx

Request a price and lead time

Ex d terminal and junction boxes, EJB, EJBX, GUB and GUBX series. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the EJB and GUB series differ?

EJB is suitable for gas group IIB+H2 and GUB for gas group IIC. Both are aluminium, while EJBX and GUBX are stainless steel.

What is the lowest ambient temperature?

Down to −60 °C for all four series.

Can a box be ordered with a window?

Yes, a window of tempered, heat-resistant glass can be built into the enclosure.