International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

CUBEx 8264/-ExV lighting and heating circuit distribution boards, Ex d, 230–400 V, 100 A

CUBEx Series 8264/-ExV are modular lighting and heating circuit distribution boards in a wall-mounted aluminium Ex d enclosure. They are rated 230 ... 400 V and 100 A for Zones 1, 2, 21 and 22, with 12 or 24 breakers.

Series
8264/-ExV CUBEx
Enclosure type of protection
Ex d
Installation zones
1, 2, 21, 22
AC rated operational voltage
230 ... 400 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

CUBEx boards of Series 8264/-ExV are built from modules, so a large number of standard variants exists and further versions are available on request. The enclosure uses the Ex d type of protection and is made of aluminium; it is lightweight, saltwater-resistant and suited to a wide range of temperatures. It is wall-mounted using screws or rails.

Every board contains a load and motor switch as built-in unit 1. Lighting boards carry 12 or 24 single-pole 16 A breakers with tripping characteristic C. Heating boards carry 12 or 24 single-pole 16 A+N / 30 mA residual current breakers with overcurrent release, characteristic B or C.

Rated operational voltage is 230 ... 400 V AC and rated current 100 A, temperature class T6. Installation is in Zones 1, 2, 21 and 22. Ambient temperature is -20 °C to +40 °C and degree of protection IP65. The entries are M50 x 1.5 and M20 x 1.5. The 12-breaker versions weigh 100 kg and the 24-breaker versions 156 kg.

Certificates are ATEX (DEK), IECEx (DEK), Canada / USA (UL), India (PESO), Korea (KGS), Brazil (ULB), China (NEPSI) and Taiwan (ITRI); degrees of protection follow IEC 60529 and explosion protection IEC 60079. Types are 8264/5-ExV-01-12L16C1P-D and 8264/5-ExV-02-24L16C1P-D for lighting, and 8264/5-ExV-01-12H16B1N-D, 8264/5-ExV-01-12H16C1N-D, 8264/5-ExV-02-24H16B1N-D and 8264/5-ExV-02-24H16C1N-D for heating.

Technical specifications

Series8264/-ExV CUBEx
Enclosure type of protectionEx d
Installation zones1, 2, 21, 22
AC rated operational voltage230 ... 400 V
Rated operational current100 A
Temperature classT6
Built-in unit 11 x load and motor switch
Breakers in lighting boards12 or 24 x 1-pole 16 A / C
Residual current breakers in heating boards12 or 24 x 1-pole 16 A+N / 30 mA / B or C
Enclosure materialaluminium
Degree of protectionIP65
Ambient temperature-20 °C ... +40 °C
Cable entriesM50 x 1.5, M20 x 1.5
Weight100 kg (12 breakers), 156 kg (24 breakers)
StandardsIEC 60529, IEC 60079
CertificatesATEX (DEK), IECEx (DEK), Canada / USA (UL), India (PESO), Korea (KGS), Brazil (ULB), China (NEPSI), Taiwan (ITRI)

Part numbers

Show all part numbers (6)

143210, 143212, 143214, 143216, 143217, 143218

How it compares with similar models

ParameterCUBEx 8264/-ExV lighting and heating circuit distribution boards, Ex d, 230–400 V, 100 ASeries 8146 lighting and heating circuit distribution boards, Ex db eb, 230–400 V, 32–80 A, IP66Series 8537 safety switch, 250 A, 690 V / 500 V, Ex db eb IIC T5 Gb, IP65CUBEx Series 8264/5 standard motor control units, Ex db IIB+H2 T6 Gb, 400 V, IP66
Rated operational current100 A32 A, 48 A, 64 A, 80 A250 A—
Enclosure materialaluminiumpolyester resinsheet steel, paintedcopper-free aluminium, seawater-resistant
Degree of protectionIP65IP66IP65IP66
StandardsIEC 60529, IEC 60079IEC 60529, IEC 60079, IEC/EN 60695, UL 94, ASTM D635IEC 60947-3, EN 60947, DIN VDE 0660 part 107IEC 60529
CertificatesATEX (DEK), IECEx (DEK), Canada / USA (UL), India (PESO), Korea (KGS), Brazil (ULB), China (NEPSI), Taiwan (ITRI)ATEX (PTB), IECEx (PTB), USA (FM), India (PESO), Korea (KGS), China (NEPSI), Taiwan (ITRI)IECEx (PTB), ATEX (PTB)ATEX (DEK), IECEx (DEK), India (PESO), Canada / USA (UL), Korea (KGS), Taiwan (ITRI), China (NEPSI), China (CCC)

Request a price and lead time

CUBEx 8264/-ExV lighting and heating circuit distribution boards, Ex d, 230–400 V, 100 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What type of protection does the CUBEx enclosure have?

The aluminium enclosure uses Ex d; the boards are suitable for Zones 1, 2, 21 and 22.

Which breakers are fitted?

Lighting boards carry 12 or 24 type C 16 A breakers; heating boards carry 12 or 24 residual current breakers 16 A+N / 30 mA, type B or C.

How is the board mounted and how much does it weigh?

It is wall-mounted using screws or rails. The 12-breaker version weighs 100 kg and the 24-breaker version 156 kg.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides