Series 7146/5-V11 load disconnect and manual transfer switches, 15–150 A, GRP, Class I Div. 2
Series 7146/5-V11 offers load disconnect and manual transfer switches for 15 - 150 A and up to 600 V AC / 240 V DC, in fused and non-fused versions. The enclosure is glass fibre reinforced polyester, enclosure type 3, 4, 4X, IP66, for Class I, Div. 2 / AEx Zone 2.
- Series
- 7146/5-V11
- Rated operational current
- 15 - 150 A
- Rated operational voltage
- up to 600 V AC / 240 V DC
- AC voltage
- 480 V, 600 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Series 7146/5-V11 switches are engineered for hazardous locations and harsh environments, with a corrosion-resistant enclosure and a wide temperature range. They are installed close to field equipment such as control panels, motors, skids or machinery. A disconnect switch fully de-energises equipment for service or maintenance; a transfer switch keeps essential equipment supplied.
The enclosure is glass fibre reinforced polyester (GRP) and lightweight. Enclosure type is 3, 4, 4X, IP66, and no conduit seal is required. Entries are not pre-installed in the standard versions, so size, location and type are left to the user. The rotary actuator is black, sturdy and padlockable.
The current rating is 15 - 150 A, in 3-pole and 3-pole + N form, fused or non-fused. Rated voltages are AC 480 V and 600 V and DC 60 V, 125 V and 240 V, at 50 – 60 Hz. Horsepower ratings are 10, 15, 20, 40, 60, 75 and 100 hp, with short circuit protection of 10, 20 and 25 kA. Temperature classes are T4 and T5. Connection cross-section is 14 AWG ... 300 kcmil and service life is at least 10^5 operating cycles.
Hazardous area classification is Class I, Div. 2, Groups A,B,C,D; Zone 2 IIC, to NEC 500, NEC 505, NEC 506 and CE Code Section 18. Certificates are USA (FM) and Canada (FM). Type designations follow 7146/5-V11-D07-00-0000-0 (80 A, 3-pole, non-fused) and 7146/5-V11-E01-AA-0000-0 (15 A, 3-pole + N, fused).
Technical specifications
| Series | 7146/5-V11 |
|---|---|
| Rated operational current | 15 - 150 A |
| Rated operational voltage | up to 600 V AC / 240 V DC |
| AC voltage | 480 V, 600 V |
| DC voltage | 60 V, 125 V, 240 V |
| Number of poles | 3-pole, 3-pole + N |
| Version | fused, non-fused |
| Horsepower rating | 10 hp, 15 hp, 20 hp, 40 hp, 60 hp, 75 hp, 100 hp |
| Short circuit protection (sym RMS) | 10 kA, 20 kA, 25 kA |
| Temperature class | T4, T5 |
| Frequency range | 50 – 60 Hz |
| Enclosure type | 3, 4, 4X, IP66 |
| Body material | glass fibre reinforced polyester (GRP) |
| Handle colour | black |
| Service life | min. 10^5 operating cycles |
| Connection cross section, stranded | 14 AWG ... 300 kcmil |
| Hazardous area | Class I, Div. 2, Groups A,B,C,D; Zone 2 IIC |
| Certificates | USA (FM), Canada (FM) |
Part numbers
Show all part numbers (26)
286738, 286735, 286736, 286730, 286731, 286737, 286742, 286733, 286734, 286732, 286748, 286743, 286747, 286753, 286754, 286755, 286744, 286749, 286751, 286740, 286745, 286752, 286741, 286746, 286739, 286750
How it compares with similar models
| Parameter | Series 7146/5-V11 load disconnect and manual transfer switches, 15–150 A, GRP, Class I Div. 2 | Series 7150/5-V11 load disconnect and manual transfer switches, stainless steel, 15–150 A, Class I Div. 2 | Series 8146/5-V11 load disconnect and manual transfer switches, 15–150 A, up to 600 V AC / 240 V DC | Series 8150/5-V11 load disconnect and manual transfer switches, stainless steel, 15–150 A |
|---|---|---|---|---|
| Number of poles | 3-pole, 3-pole + N | 3-pole, 3-pole + N | 1-pole, 2-pole, 3-pole, 3-pole + N | 3-pole, 3-pole + N, 1-pole, 2-pole |
| Version | fused, non-fused | fused, non-fused | non-fused | non-fused |
| Horsepower rating | 10 hp, 15 hp, 20 hp, 40 hp, 60 hp, 75 hp, 100 hp | 10 hp, 15 hp, 20 hp, 40 hp, 60 hp, 75 hp, 100 hp | 10 hp, 15 hp, 20 hp, 40 hp, 60 hp, 75 hp, 100 hp | 10 hp ... 100 hp |
| Temperature class | T4, T5 | T4, T5 | — | T4 / 130 °C, T5 / 95 °C, T6 / 80 °C |
| Body material | glass fibre reinforced polyester (GRP) | stainless steel 1.4404 (AISI 316L) | glass fibre reinforced polyester (GRP / FRP) | stainless steel 1.4404 (AISI 316L) |
| Connection cross section, stranded | 14 AWG ... 300 kcmil | 14 AWG ... 300 kcmil | 14 AWG ... 8 AWG, 12 AWG ... 6 AWG, 10 AWG ... 300 kcmil, 1/0 AWG | 14 AWG ... 8 AWG, 12 AWG ... 6 AWG, 10 AWG ... 300 kcmil, 10 AWG ... 1/0 AWG |
Request a price and lead time
Series 7146/5-V11 load disconnect and manual transfer switches, 15–150 A, GRP, Class I Div. 2. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which fuse options are offered?
Fused and non-fused versions, rated 15 - 150 A. The GRP enclosure is classified Class I, Div. 2 / AEx Zone 2.
Which current and voltage ratings are available?
A current rating of 15 - 150 A and voltages up to 600 V AC / 240 V DC.
Is a conduit seal required?
No. Entries are not pre-installed in the standard versions, so their size, location and type are chosen by the user.