YA60/3 YODALEX 3 audible signalling device, up to 120 dB(A), aluminium, IP66
The YA60/3 from the YODALEX 3 range sounds alarms in hazardous areas. The directional horn reaches 120 dB(A) at 1 m, the omnidirectional one 114 dB(A). Aluminium enclosure to IP66, Ex d or Ex e connection chamber, ATEX and IECEx.
- Type
- Audible signalling device YA60/3
- Sound pressure level
- max. 120 dB(A) at 1 m (directional); max. 114 dB(A) at 1 m (omnidirectional)
- Tone channels / tones
- 4 / 64 preconfigured
- Rated operational voltage DC
- 12 ... 27.2 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The YA60/3 horn (YODALEX 3 range) draws attention to equipment malfunction or start-up and to other safety-related situations in hazardous areas. Four channels are available for each signal, so one device can serve several events.
The horn is directional or omnidirectional. The directional version delivers up to 120 dB(A) at 1 m, the omnidirectional version up to 114 dB(A). There are four tone channels and 64 preconfigured tones that follow internationally standardised signal schemes, and four output levels can be configured.
The enclosure is powder-coated aluminium, resistant to seawater, red and close to RAL 3020. The trumpet is PC/PBT, the mounting part is stainless steel and the degree of protection is IP66. Brackets and fixings are stainless steel, and the fastening bracket is supplied.
Versions differ in horn type, connection chamber and voltage. The Ex e chamber has 2 x M20 + 2 x M25 holes, the Ex d chamber 2x M20 + 2x 1/2". Supply is DC 12 ... 27.2 V, plus 133 ... 272 V and 110 ... 240 V AC, 50 Hz / 60 Hz. Terminals are push-in, up to 4 mm² solid and 2.5 mm² finely stranded. Entries are 1 x M20 for Ø 4 ... 13 mm and 1 x M25 for Ø 7 ... 17 mm, with stopping plugs in the remaining holes.
IECEx gas marking is Ex db eb IIC T6 / T4 Gb for the directional horn and Ex db IIC T6 / T4 Gb for the Ex d version; dust marking is Ex tb IIIC T80 °C / T100 °C Db. Ambient temperature is -40 °C ... 40 °C (T6) and -40 °C ... 70 °C (T4), storage -60 °C ... +70 °C. Weight is 6.21 kg ... 8.41 kg.
Technical specifications
| Type | Audible signalling device YA60/3 |
|---|---|
| Sound pressure level | max. 120 dB(A) at 1 m (directional); max. 114 dB(A) at 1 m (omnidirectional) |
| Tone channels / tones | 4 / 64 preconfigured |
| Rated operational voltage DC | 12 ... 27.2 V |
| Rated operational voltage AC | 133 ... 272 V; 110 ... 240 V, 50 Hz / 60 Hz |
| Degree of protection | IP66 |
| Enclosure material | Aluminium, powder-coated, seawater-resistant |
| Trumpet material | PC/PBT |
| Mounting part material | Stainless steel |
| Terminals | Push in; up to 4 mm² solid, up to 2.5 mm² finely stranded |
| Drilled holes | 2 x M20 + 2 x M25 (Ex e); 2x M20 + 2x 1/2" (Ex d) |
| IECEx gas | Ex db eb IIC T6 / T4 Gb (directional); Ex db IIC T6 / T4 Gb (Ex d) |
| IECEx dust | Ex tb IIIC T80 °C / T100 °C Db |
| Ambient temperature | -40 °C ... 40 °C (T6); -40 °C ... 70 °C (T4) |
| Storage temperature | -60 °C ... +70 °C |
| Dimensions | ~336 x ~160 x ~128 mm (omnidirectional); ~319 x ~160 x ~128 mm (directional) |
| Weight | 6.21 kg ... 8.41 kg |
Part numbers
Show all part numbers (7)
319422, 319423, 312375, 322576, 327770, 327525, 321474
How it compares with similar models
| Parameter | YA60/3 YODALEX 3 audible signalling device, up to 120 dB(A), aluminium, IP66 | FL60/3 YODALEX 3 visual signalling device with connection chamber, LED / 5 J, IP66/67 | YL60/3 YODALEX 3 audible and visual signalling device, up to 120 dB(A), LED / 5 J | 6125/2 LED floodlight, 100 ... 225 W, for Zone 1, stainless steel, IP66, IK10 |
|---|---|---|---|---|
| Type | Audible signalling device YA60/3 | Visual signalling device FL60/3 | Audible and visual signalling device YL60/3 | 6125/2 LED floodlight |
| Rated operational voltage DC | 12 ... 27.2 V | 12 ... 27.20 V; 133 ... 272 V | 12 ... 27.2 V; 133 ... 272 V | — |
| Enclosure material | Aluminium, powder-coated, seawater-resistant | Aluminium, powder-coated, seawater-resistant | — | Stainless steel 1.4404 (316L); 1.4301 |
| Drilled holes | 2 x M20 + 2 x M25 (Ex e); 2x M20 + 2x 1/2" (Ex d) | 2 x M20 + 2 x M25; 2x M20 + 2x 1/2" | 2 x M20 + 2 x M25; 2x M20 + 2x 1/2" | 3 x M20; 3 x M25; 4 x M25 |
| Ambient temperature | -40 °C ... 40 °C (T6); -40 °C ... 70 °C (T4) | -40 °C ... 40 °C (T6); -40 °C ... 60 °C (T4); -40 °C ... 70 °C (T4) | — | -60 °C ... +60 °C |
| Weight | 6.21 kg ... 8.41 kg | 5.15 ... 6.02 kg | 8.23 ... 8.92 kg | 16.5 kg ... 19 kg |
Request a price and lead time
YA60/3 YODALEX 3 audible signalling device, up to 120 dB(A), aluminium, IP66. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the difference between the directional and omnidirectional horn?
The directional horn reaches 120 dB(A) at 1 m, the omnidirectional horn 114 dB(A).
What ambient temperature is permitted?
-40 °C ... 40 °C for T6 and -40 °C ... 70 °C for T4. Storage is -60 °C ... +70 °C.
Which cable entries do the Ex e and Ex d chambers have?
The Ex e chamber has 2 x M20 + 2 x M25, the Ex d chamber 2x M20 + 2x 1/2".