International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Series 8003/1.3 panel mounting buttons and switches with 6 m cable, ATEX/IECEx and NEC® / CE Code, 6 A

These Series 8003/1.3 buttons and switches for panel mounting switch circuits up to 6 A. They come with a 6 m cable, 500 V AC, IP65 or IP66, Ex db eb IIC T6 Gb, and ATEX, IECEx, UL, NEC® and CE Code approval.

Connection
Plug-in, 6 m cable, 4 × 1 mm²
Connection cross-section
0.75 ... 1.5 mm² (20 AWG ... 14 AWG)
AC rated operational voltage
500 V
Rated operational current
6 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8003/1.3 control buttons and switches for panel mounting switch load, control and signal circuits up to 6 A. Depending on the type, they are fully or incompletely explosion-protected equipment, with corresponding requirements for installation. The UL versions are meant for NEC® and CE Code applications.

The plug-in connection has a 6 m cable (4 × 1 mm²) and a connection cross-section of 0.75 ... 1.5 mm² (20 AWG ... 14 AWG). Installation needs a single hole (D 30). Actuators include pushbutton, mushroom pushbutton, mushroom stay-put button with key lock, key-operated button and switch, EM-STOP, a small rotary actuator not padlockable, and key actuator MS1. The latching, spring return and key not removable functions are codable.

Rated operational voltage AC is 500 V and rated operational current is 6 A. Switching capacity is AC-12500 V / 6 A / max. 3000 VA, AC-15400 V / 6 A / max. 1250 VA and DC-13 60 V / 6 A. Protection is IP65 or IP66. Mounting depth is 130 mm, the size is 130 × 52 × 38 mm, tightening torque is 3 N·m, and minimum service life is 10^5 operating cycles. Weight is 125 to 730 g.

Explosion protection is Ex db eb IIC T6 Gb and Ex tb IIIC T80 °C Db, for Zone 0, 1, 2, 20, 21, 22 and Division 1 and 2. Standards are IEC 60529, NEC® 500, 505, 506 and CE Code Section 18. Certificates are ATEX, IECEx, UL, China (CQST) and Korea (KGS).

Technical specifications

ConnectionPlug-in, 6 m cable, 4 × 1 mm²
Connection cross-section0.75 ... 1.5 mm² (20 AWG ... 14 AWG)
AC rated operational voltage500 V
Rated operational current6 A
Switching capacity AC-12500 V / 6 A / max. 3000 VA
Switching capacity AC-15400 V / 6 A / max. 1250 VA
Switching capacity DC-1360 V / 6 A
Degree of protectionIP65, IP66
Mounting depth130 mm
Dimensions130 × 52 × 38 mm
Service life, min.10^5 operating cycles
Explosion protectionEx db eb IIC T6 Gb; Ex tb IIIC T80 °C Db
StandardsIEC 60529; NEC® 500, 505, 506; CE Code Section 18
Weight125 ... 730 g

Part numbers

Show all part numbers (4)

8003/113-726-2-r-6 UL (213524), 217964, 213516, 217965

How it compares with similar models

ParameterSeries 8003/1.3 panel mounting buttons and switches with 6 m cable, ATEX/IECEx and NEC® / CE Code, 6 ASeries 8003/1.3 panel mounting control buttons and switches with 6 m cable, 500 V AC, 6 A, ATEX/IECExSeries 8003/1.1 panel mounting control buttons and switches, Ex e, 500 V AC, 6 A, ATEX/IECExSeries 8018 LED illuminated pushbutton for panel mounting, ATEX/IECEx and NEC® / CE Code
Switching capacity DC-1360 V / 6 A60 V / 6 A60 V / 6 A110 V / 1 A / max. 110 W
Mounting depth130 mm130 mm130 mm104.5 mm
Explosion protectionEx db eb IIC T6 Gb; Ex tb IIIC T80 °C DbEx db eb; Ex tbEx db eb IIC T6 Gb; Ex tb IIIC T80 °C DbEx db mb IIC T6 Gb; Ex db mb ia IIC T6 Gb; Ex tb IIIC T80 °C Db

Request a price and lead time

Series 8003/1.3 panel mounting buttons and switches with 6 m cable, ATEX/IECEx and NEC® / CE Code, 6 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the UL version differ from the ATEX/IECEx Series 8003/1.3?

It is also meant for NEC® 500, 505, 506 and CE Code Section 18 applications, including Division 1 and 2.

What cable and connection cross-section are used?

A 6 m cable (4 × 1 mm²) with a connection cross-section of 0.75 ... 1.5 mm² (20 AWG ... 14 AWG).

What are the service life and protection degree?

Minimum service life is 10^5 operating cycles and protection is IP65 or IP66.