MiniCON 8595/1 explosion-protected couplings, up to 500 V/16 A, 7 P + PE / 8 P
Series 8595/1 miniCON couplings are the in-line mating half for the series plugs in Zones 1, 2, 21 and 22. They are rated 500 V AC and 16 A with up to eight poles and conductors of 0.25 mm² to 2.5 mm². Plastic, stainless steel 1.4404 or nickel-plated brass, IP66/IP67.
- Type
- miniCON coupling, Series 8595/1
- Rated operational voltage AC
- 500 V
- Rated operational voltage DC
- max. 110 V
- Rated insulation voltage
- 690 V
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The miniCON coupling of Series 8595/1 is the cable-mounted counterpart to the plugs of the same series. It is used in Zones 1, 2, 21 and 22 for signal and power circuits up to 500 V/16 A, with up to eight poles, and comes in a plastic or stainless steel body.
Hot swap capability allows intrinsically safe circuits up to 500 V/16 A to be disconnected without a hot work permit. The modular structure keeps mounting short, and the connection is made one-handed with a patented mechanism. The installer sets internal coding for up to three applications.
Ratings are 500 V AC, max. 110 V DC, 690 V rated insulation voltage and 16 A for AC and DC at 50 - 60 Hz. The pole configuration is 7 P + PE / 8 P. Conductor cross-sections span 0.25 mm² to 2.5 mm² (24 AWG - 16 AWG), with versions for 0.5 mm², 0.75 - 1 mm², 1.5 mm² and 2.5 mm².
The connection thread is M20 x 1.5 or M25 x 1.5, and the body is plastic, stainless steel 1.4404 or nickel-plated brass. Degrees of protection are IP66 and IP67 to IEC 60529 and IP64 to IEC 60079. Ambient temperature is -60 °C ... 75 °C. The coupling is 109.10 mm long with a diameter of 42 mm; dimension X depends on the cable gland. Weight is up to 323 g. Some versions are marked reverse.
Technical specifications
| Type | miniCON coupling, Series 8595/1 |
|---|---|
| Rated operational voltage AC | 500 V |
| Rated operational voltage DC | max. 110 V |
| Rated insulation voltage | 690 V |
| Rated operational current AC/DC | 16 A |
| AC frequency range | 50 - 60 Hz |
| Poles | 7 P + PE / 8 P |
| Connection cross-section | 0.25 mm² to 2.5 mm² (24 AWG - 16 AWG) |
| Connection thread | M20 x 1.5; M25 x 1.5 |
| Body material | Plastic; stainless steel 1.4404; nickel-plated brass |
| Degree of protection | IP66, IP67 (IEC 60529); IP64 (IEC 60079) |
| Ambient temperature | -60 °C ... 75 °C |
| Zones | 1, 2, 21, 22 |
| Length / diameter | 109.10 mm / Ø 42 mm |
| Weight | up to 323 g |
Part numbers
Show all part numbers (5)
286569, 286605, 286560, 286617, 286618
How it compares with similar models
| Parameter | MiniCON 8595/1 explosion-protected couplings, up to 500 V/16 A, 7 P + PE / 8 P | MiniCON 8595/1 explosion-protected plugs, up to 500 V/16 A, 7 P + PE / 8 P | MiniCON 8595/1 flange socket for Ex e enclosures, 500 V/16 A, M32 x 1.5 | MiniCON 8595/1 device plug for Ex e enclosures, 500 V/16 A, M32 x 1.5 |
|---|---|---|---|---|
| Type | miniCON coupling, Series 8595/1 | miniCON plug, Series 8595/1 | miniCON flange socket for Ex e enclosure | miniCON device plug for Ex e enclosure |
| Connection cross-section | 0.25 mm² to 2.5 mm² (24 AWG - 16 AWG) | 0.25 mm² to 2.5 mm² (14 AWG to 24 AWG) | 0.25 mm² to 2.5 mm² | 0.25 mm² to 2.5 mm² |
| Connection thread | M20 x 1.5; M25 x 1.5 | — | M32 x 1.5 | M32 x 1.5 |
| Weight | up to 323 g | 174 g; 491 g | 400 g | 567 g |
Request a price and lead time
MiniCON 8595/1 explosion-protected couplings, up to 500 V/16 A, 7 P + PE / 8 P. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which zones are the 8595/1 couplings intended for?
Zones 1, 2, 21 and 22.
Which conductor cross-sections and threads are offered?
Cross-sections of 0.5 mm², 0.75 - 1 mm², 1.5 mm² and 2.5 mm², with M20 x 1.5 and M25 x 1.5 threads.
What are the weight and size of the coupling?
It is 109.10 mm long with a 42 mm diameter and weighs up to 323 g depending on the body material.
Similar equipment from other manufacturers