Series MBA-Ex Ex e / Ex i Terminal Boxes, Aluminium, IP66, Zones 1, 2, 21, 22, T4 to T6
Series MBA-Ex aluminium Ex e / Ex i terminal boxes suit zones 1, 2, 21 and 22 in temperature classes T4 to T6. Protection is IP66, sizes run from 58 x 64 x 34 mm to 600 x 310 x 180 mm, and each box can be equipped individually.
- Type of protection
- Ex e / Ex i
- Enclosure material
- Aluminium AlSi(Cu)
- Degree of protection IP (IEC 60529)
- IP66
- Zones
- 1, 2, 21, 22
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The aluminium Ex e / Ex i terminal enclosures meet all requirements for installation areas in which explosive concentrations of gases, vapours and dusts may occur, namely zones 1 and 2 and zones 21 and 22. MBA-Ex e / Ex i enclosures can be used in temperature classes T4 to T6 and can be individually equipped.
With terminals fitted in temperature class T6, temperatures above 85 °C will not occur inside or outside, so combustible gases, vapours or dusts cannot be ignited. The enclosures join the equipotential bonding through the external earth connection, which prevents static charging and the resulting sparks.
Terminal enclosures in the increased safety e type of protection may be combined with intrinsically safe i circuits where the space allows. A clearance and creepage distance of at least 50 mm must be kept between the terminals of the two circuits, and the additional heating of the intrinsically safe circuits can be disregarded.
The marking is Ex e IIC T6 / T4 Gb, Ex tb IIIC T80 °C / T100 °C Db and Ex ia IIC T6 / T4 Gb. Protection is IP66 (IEC 60529) and the material is aluminium AlSi(Cu). IECEx and ATEX certificates are listed. Sizes run from 58 x 64 x 34 mm to 600 x 310 x 180 mm.
Examples from the table are MBA Ex-e 101080 (100 x 100 x 80 mm, 10 terminals of 2.5 mm², 780 g), MBA Ex-e 141490 (140 x 140 x 90 mm, 17 terminals, 1.34 kg) and MBA Ex-e 201490 (200 x 140 x 90 mm, 29 terminals, 1.64 kg).
Technical specifications
| Type of protection | Ex e / Ex i |
|---|---|
| Enclosure material | Aluminium AlSi(Cu) |
| Degree of protection IP (IEC 60529) | IP66 |
| Zones | 1, 2, 21, 22 |
| Temperature classes | T4 - T6 |
| Explosion protection (gas) | Ex e IIC T6 / T4 Gb; Ex ia IIC T6 / T4 Gb |
| Explosion protection (dust) | Ex tb IIIC T80 °C / T100 °C Db |
| Min. distance between Ex e and Ex i circuits | 50 mm |
| Dimensions | 58 x 64 x 34 mm to 600 x 310 x 180 mm |
| Max. no. of 2.5 mm² terminals | 10 - 29 (depending on size) |
| Certificates | IECEx, ATEX |
Part numbers
Show all part numbers (1)
312512
How it compares with similar models
| Parameter | Series MBA-Ex Ex e / Ex i Terminal Boxes, Aluminium, IP66, Zones 1, 2, 21, 22, T4 to T6 | Series 8151 Terminal Boxes, Ex eb IIC T6 / T5 Gb, Stainless Steel 1.4404, IP66, 14 Sizes | Series 8118 Terminal Boxes, Ex e / Ex i, Three Design Sizes, up to 690 V, IP66 | NEC/IEC Series 8150 Ex e Terminal Boxes, Stainless Steel 1.4404, IP66, 690 V |
|---|---|---|---|---|
| Type of protection | Ex e / Ex i | Ex e | — | Ex e |
| Enclosure material | Aluminium AlSi(Cu) | Stainless steel 1.4404 / 316L | Polyester resin, glass fibre reinforced | Stainless steel 1.4404 (AISI 316L), brush finished |
| Dimensions | 58 x 64 x 34 mm to 600 x 310 x 180 mm | 116.5 x 176.5 x 91 mm to 400 x 600 x 230 mm | — | 7 x 7 x 3.6 inch; 9.3 x 7 x 3.6 inch |
| Certificates | IECEx, ATEX | ATEX, IECEx, PESO, ITRI | ATEX, IECEx, NEPSI, PESO, KTL, ULB, DNV | cULus, IECEx, ATEX, NEPSI, ITRI |
Request a price and lead time
Series MBA-Ex Ex e / Ex i Terminal Boxes, Aluminium, IP66, Zones 1, 2, 21, 22, T4 to T6. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can Ex e and Ex i circuits share one box?
Yes, where the space allows. A clearance and creepage distance of at least 50 mm must be kept between the terminals of the two circuits.
Which temperature classes do MBA-Ex boxes cover?
Classes T4 to T6. At T6 with terminals fitted, temperatures above 85 °C do not occur inside or outside.
What protection rating and material apply?
IP66 (IEC 60529) and aluminium AlSi(Cu).