Series 8455 potentiometer for panel mounting, 100 Ω to 1 MΩ, 2 W

Series 8455 potentiometers are installed in panels and come with a connection cable or with connection terminals. Resistance covers 100 Ω to 1 MΩ at 2 W, for Zones 1, 2, 21 and 22. The target value is set with a rotary actuator.

Series
8455
Resistance range
100 Ω ... 1 MΩ
Maximum resistance Rmax
1000 Ω; 2200 Ω; 4700 Ω; 10000 Ω; 1000000 Ω
Power
2 W

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 8455 potentiometers are built into panels and are supplied either with a connection cable or with screw terminals. The resistance range is 100 Ω to 1 MΩ, the power rating 2 W and the rated operational voltage 400 V. A rotary actuator sets the target value on a scale of 0 ... 10 or 0 ... 100.

Maximum resistance Rmax is available as 1000 Ω, 2200 Ω, 4700 Ω, 10000 Ω or 1000000 Ω. Resistance tolerance is ± 20 %, the characteristic is linear and the resistor material is carbon film. The rotation range is 270°, the torque 0.7 ... 2 Ncm and the stop strength more than 100 Ncm. The enclosure is polyamide and the design is silicone-free.

There are two connection types. Type 8455/2 carries a 6 m HO5VV-F, 3 x 0.75 cable and has IP66 protection. Type 8455/4 uses a screw connector and has IP20. The body diameter is ø 45 mm and the mounting hole 32 mm.

The types of protection are db mb and mb, for Zones 1, 2, 21 and 22, with ambient temperature from -20 °C to +40 °C. Certificates are IECEx (PTB) and ATEX (PTB). The type designation carries the options, for example 8455/2-1kΩ-0/100-6 stands for a 1 kΩ maximum resistance, a 0 ... 100 scale and a 6 m cable.

Technical specifications

Series8455
Resistance range100 Ω ... 1 MΩ
Maximum resistance Rmax1000 Ω; 2200 Ω; 4700 Ω; 10000 Ω; 1000000 Ω
Power2 W
Rated operational voltage400 V
Resistance tolerance± 20 %
Characteristiclinear
Resistor materialcarbon film
Enclosure materialpolyamide
Rotation range270°
Torque0.7 ... 2 Ncm
Stop strength> 100 Ncm
Scale0 ... 10; 0 ... 100
Connection8455/2: 6 m HO5VV-F, 3 x 0.75 cable; 8455/4: screw connector
Degree of protectionIP66 (8455/2), IP20 (8455/4)
Type of protectiondb mb; mb
Ambient temperature-20 °C ... +40 °C
Dimensionsø 45 mm (32 mm mounting hole)
CertificatesIECEx (PTB), ATEX (PTB)

Part numbers

Show all part numbers (13)

218543, 244978, 218552, 218545, 218544, 218542, 218535, 218534, 218548, 218547, 218538, 218537, 218536

How it compares with similar models

ParameterSeries 8455 potentiometer for panel mounting, 100 Ω to 1 MΩ, 2 WSeries 8537 safety switch, 250 A, 690 V / 500 V, Ex db eb IIC T5 Gb, IP65Series 8581/41100 A wall-mounting socket for Class I, Div. 2 and Zone 1/21, IP66Series 8570/25 SolConeX 20 A flange socket for installation in an enclosure, NEC 505
Rated operational voltage400 V—480 V AC; 600 V AC; 208Y/120 V AC; 480Y/277 V AC600 V AC; 480 V AC; 347 to 400/600 V AC; 277/480 V AC; 200 ... 250 V AC; 120/208 ... 144/250 V AC; 100 ... 130 V AC
Degree of protectionIP66 (8455/2), IP20 (8455/4)IP65IP66—
Ambient temperature-20 °C ... +40 °C-20 °C ... +40 °C-30 ... +45 °C-50 ... +35 °C
CertificatesIECEx (PTB), ATEX (PTB)IECEx (PTB), ATEX (PTB)FM, IECEx, ATEXATEX, IECEx, FM

Request a price and lead time

Series 8455 potentiometer for panel mounting, 100 Ω to 1 MΩ, 2 W. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which maximum resistance values are available?

1000 Ω, 2200 Ω, 4700 Ω, 10000 Ω and 1000000 Ω. The series covers 100 Ω to 1 MΩ.

What is the difference between 8455/2 and 8455/4?

8455/2 has a 6 m cable and IP66 protection; 8455/4 connects to a screw connector and has IP20.

Which zones is the potentiometer suitable for?

Zones 1, 2, 21 and 22, at ambient temperatures from -20 °C to +40 °C. Certificates are IECEx (PTB) and ATEX (PTB).