International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

C-LUX Series 6102 Compact LED Light Fittings, Ex db eb ib op is IIC T4 Gb, IP66/IP67

C-LUX Series 6102 are compact LED fittings for normal lighting or for emergency use together with exit signs. Marked Ex db eb ib op is IIC T4 Gb and Ex tb op is IIIC T100 °C Db for zones 1, 2, 21 and 22, with IP66/IP67 enclosure protection.

Lamp
LED
Colour temperature
5000 K
Luminous flux
490 ... 775
Control interface
without; DALI; Internal address module

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The C-LUX 6102 compact fittings serve as normal luminaires or as emergency luminaires, combined with emergency exit signs and/or an address module for central battery systems. They can be fixed to a wall or ceiling, or suspended. The body is lightweight and compact.

Control is by DALI or by an internal address module, and a version without an interface is also listed. Exit signs use a suspended panel so the legend reads from both sides, with a recognition range of d ≥ 30 m. Single-sided and double-sided variants are offered for escape routes downstairs, to the left and to the right. Wiring is loop in / loop out.

The light source is LED at 5000 K with a luminous flux of 490 ... 775 depending on the variant. Supply is 100 ... 240 V AC at 50 – 60 Hz, or 100 ... 250 V DC. Protection class I. The enclosure is thermoset, the cover polycarbonate and the seal silicone. Ingress protection is IP66 / IP67 and impact strength IK08.

Explosion protection is Ex db eb ib op is IIC T4 Gb for gas and Ex tb op is IIIC T100 °C Db for dust, covering Zone 1 | 2 G | Gb / Zone 2 | 3 G | Gc / Zone 21 | 2 D | Db / Zone 22 | 3 D | Dc. IECEx and ATEX certificates are listed, along with IEC 60598 and IEC 62262. Ambient temperature range is -40 to +50 °C.

Two M25 entries take cable of Ø 7 … 17 mm, and the housing carries 3 drilled M25 holes. Terminals accept 6 mm² solid and 4 mm² finely stranded conductors. A fitting weighs 3.57 kg.

Technical specifications

LampLED
Colour temperature5000 K
Luminous flux490 ... 775
Control interfacewithout; DALI; Internal address module
AC operating voltage100 ... 240 V
DC operating voltage100 ... 250 V
Frequency range50 – 60 Hz
Explosion protection (gas)Ex db eb ib op is IIC T4 Gb
Explosion protection (dust)Ex tb op is IIIC T100 °C Db
ZoneZone 1 | 2 G | Gb / Zone 2 | 3 G | Gc / Zone 21 | 2 D | Db / Zone 22 | 3 D | Dc
IP degree of protectionIP66 / IP67
Impact strengthIK08
ClassI
Ambient temperature-40 ... +50 °C
Cable entries2 x M25 Ø 7 … 17 mm
Enclosure / cover / seal materialThermoset / Polycarbonate / Silicone
Terminals, solid / finely stranded6 mm² / 4 mm²

Part numbers

Show all part numbers (8)

287773, 287785, 287793, 287700, 287782, 287790, 287771, 287699

How it compares with similar models

ParameterC-LUX Series 6102 Compact LED Light Fittings, Ex db eb ib op is IIC T4 Gb, IP66/IP67Series 6148 Portable LED Lamps, Ex ib IIC T4 Gb, 40000 cdSeries 6149 LED Inspection Light, Ex d IIC, Zones 1, 2, 21, 22, 1396 lmC-LUX 6109 compact emergency LED luminaire, Ex db eb ib op is IIC T4 Gb
LampLEDLEDSingle-row LED—
Luminous flux490 ... 775—1396 lmдо 775 lm
Explosion protection (gas)Ex db eb ib op is IIC T4 GbEx ib IIC T4 GbII 2 G Ex d IIC T4 Gb; II 2 G Ex d IIC T6 GbEx db eb ib op is IIC T4 Gb
Explosion protection (dust)Ex tb op is IIIC T100 °C DbEx tb IIIC T75 °C DbII 2 D Ex tb IIIC T100 °C Db; II 2 D Ex tb IIIC T80 °C DbEx tb op is IIIC T100 °C Db
ZoneZone 1 | 2 G | Gb / Zone 2 | 3 G | Gc / Zone 21 | 2 D | Db / Zone 22 | 3 D | DcZone 1 | 2 G | Gb / Zone 2 | 3 G | Gc / Zone 21 | 2 D | Db / Zone 22 | 3 D | DcZone 1 | 2 G | Gb / Zone 2 | 3 G | Gc / Zone 21 | 2 D | Db / Zone 22 | 3 D | Dc1 (2 G, Gb); 2 (3 G, Gc); 21 (2 D, Db); 22 (3 D, Dc)
ClassIII (double insulated)IIII

Request a price and lead time

C-LUX Series 6102 Compact LED Light Fittings, Ex db eb ib op is IIC T4 Gb, IP66/IP67. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What explosion protection marking does Series 6102 carry?

Ex db eb ib op is IIC T4 Gb for gas and Ex tb op is IIIC T100 °C Db for dust, for zones 1, 2, 21 and 22.

Can the fitting be controlled over DALI?

Yes. Versions with DALI or an internal address module for central battery systems exist, as well as a version without an interface.

What are the ingress protection and supply ratings?

IP66 / IP67 and IK08. Supply is 100 ... 240 V AC or 100 ... 250 V DC.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides