International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SolConeX 8571/22 30 A plug for Zone 1, 2, 21, 22

The 8571/22 SolConeX is a 30 A plug for hazardous areas classified as Zone 1, 2, 21, 22 under NEC 505. Voltage ranges follow EN 60309, the ambient range is -50 to +25 °C, cable diameter is 13 - 25 mm and a protective cap is supplied.

Product type
Explosion-protected plug
Series
8571/22 SolConeX
Rated operational current
30 A
Rated operational voltage
120/208 ... 144/250; 200 ... 250; 277/480; 347 to 400/600; 480; 600 V AC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The Series 8571/22 SolConeX plug mates with the Series 8571/21 wall socket and is classified for zone or division under NEC 505; the variants listed carry Zone 1, 2, 21, 22. Rated operational current is 30 A at 50 / 60 Hz. The manufacturer's description text calls it a 4- or 5-pole 20 A plug, but the selection table and filter state 30 A, which is the value used here.

The contact pins float, so the plug goes in and comes out easily. A pivoting strain relief makes cable fitting easier, and torsion from the cable does not act on the seal. The pins are self-cleaning and corrosion-free, made from high-quality materials for good electrical contact. A protective cap, included in delivery, keeps dirt off the pins when the plug is unplugged.

Variants differ by voltage range according to EN 60309: 120/208 ... 144/250, 200 ... 250, 277/480, 347 to 400/600, 480 and 600 V AC. Plugs come as 3-pole with 4 conductors or 4-pole with 5 conductors. The colour code is black, blue or red, with coding position 5, 7 or 9 o'clock.

Ambient temperature range is -50 to +25 °C. The plug resists mechanical impact and shock and is sealed against liquids and dust. It takes cable of 13 - 25 mm (0.51 - 0.98 in) diameter.

Certificates: ATEX (PTB), IECEx (PTB), FM (USA and Canada), PESO (India), KGS (Korea), ULB (Brazil) and ITRI (Taiwan).

Technical specifications

Product typeExplosion-protected plug
Series8571/22 SolConeX
Rated operational current30 A
Rated operational voltage120/208 ... 144/250; 200 ... 250; 277/480; 347 to 400/600; 480; 600 V AC
Frequency range50 / 60 Hz
Ambient temperature-50 ... +25 °C
Poles3-pole, 4 conductors; 4-pole, 5 conductors
Coding (clock hour position)5, 7, 9
Colour codeblack, blue, red
Cable diameter13 - 25 mm / 0.51 - 0.98 in
Zones1, 2, 21, 22
StandardsNEC 505, EN 60309

Part numbers

Show all part numbers (6)

294407, 294405, 294406, 294404, 294403, 294402

How it compares with similar models

ParameterSolConeX 8571/22 30 A plug for Zone 1, 2, 21, 22SolConeX 8571/21 30 A wall-mounting socket for Zone 1, 2, 21, 22SolConeX 8571/25 30 A flange socket for 'eb' and 'tb' enclosuresSolConeX 8579/22 60 A plug, IP66, for Class I Div. 2 and Zone 1/21
Product typeExplosion-protected plugExplosion-protected wall-mounting socketFlange socket (incomplete equipment)Explosion-protected plug
Rated operational current30 A30 A30 A60 A
Rated operational voltage120/208 ... 144/250; 200 ... 250; 277/480; 347 to 400/600; 480; 600 V AC120/208 ... 144/250; 200 ... 250; 277/480; 347 to 400/600; 480; 600 V AC120/208 ... 144/250; 200 ... 250; 277/480; 347 to 400/600; 480; 600 V AC600Y/347; 600; 480Y/277; 480; 250; 208Y/120 V AC
Ambient temperature-50 ... +25 °C-50 ... +25 °C-50 ... +25 °C-30 ... +40 °C

Request a price and lead time

SolConeX 8571/22 30 A plug for Zone 1, 2, 21, 22. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What cable diameter does the plug accept?

13 - 25 mm (0.51 - 0.98 in).

Is a protective cap supplied?

Yes, a protective cap is included in delivery.

Which socket does it mate with?

The Series 8571/21 wall socket; the Series 8571/25 flange socket is also specified for this plug.

Similar equipment from other manufacturers