РОД, РОДЦ, ОРД, ОРДЦ, ОРЦО, РТМ and РТД oil-filled shunt reactors, 10–210 MVA

Oil-filled shunt reactors of series РОД, РОДЦ, ОРД, ОРДЦ, ОРЦО, РТМ and РТД that compensate the charging power of high-voltage transmission lines. Rated power is 10–210 MVA; the HV class is 35, 220, 500 or 550 kV.

Series
РОД, РОДЦ, ОРД, ОРДЦ, ОРЦО, РТМ, РТД
Rated power
10–210 MVA
HV voltage class
35, 220, 500, 550 kV
Type designations РОД
РОД-60000/500

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The reactors in this group are oil-filled shunt reactors of series РОД, РОДЦ, ОРД, ОРДЦ, ОРЦО, РТМ and РТД. Their purpose is to compensate the charging power of high-voltage transmission lines.

Rated power is 10–210 MVA and the HV class is 35, 220, 500 or 550 kV. Series РОД and РОДЦ belong to the range, but the list of type designations shows only РОД-60000/500 for them.

Series РОД: РОД-60000/500. Series ОРД: ОРД-66667/220. Series ОРДЦ: ОРДЦ-63300/220 and ОРДЦ-210000/500.

Series ОРЦО: ОРЦО-210000/500. Series РТМ: РТМ-10000/220, РТМ-65000/550 and РТМ-128000/550. Series РТД: РТД-20000/35 and РТД-75000/220.

A type designation is a series name followed by two numbers joined by a hyphen and a slash, for example РТМ-50000/220 or ОРДЦ-210000/500. ОРЦО-210000/500 has the same power and voltage class as ОРДЦ-210000/500.

The highest voltage class in the list belongs to series РТМ: РТМ-65000/550 and РТМ-128000/550 are 550 kV units. The lowest class, 35 kV, is that of РТД-20000/35. To select a reactor, state the series, the rated power and the HV class.

Technical specifications

SeriesРОД, РОДЦ, ОРД, ОРДЦ, ОРЦО, РТМ, РТД
Rated power10–210 MVA
HV voltage class35, 220, 500, 550 kV
Type designations РОДРОД-60000/500
Type designations ОРДОРД-66667/220
Type designations ОРДЦОРДЦ-63300/220, ОРДЦ-210000/500
Type designations ОРЦООРЦО-210000/500
Type designations РТМРТМ-10000/220, РТМ-50000/220, РТМ-65000/550, РТМ-128000/550
Type designations РТДРТД-20000/35, РТД-75000/220

European equivalents

COIL HV Shunt: high-voltage shunt reactor, Shunt reactors, Shunt reactors, including variable, up to 300 Mvar, BKD / BKS 220–1000 kV oil-immersed shunt reactors, Shunt reactors, Shunt and series reactors, Air Core Shunt Reactors, Shunt reactors

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

РОД, РОДЦ, ОРД, ОРДЦ, ОРЦО, РТМ and РТД oil-filled shunt reactors, 10–210 MVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What rated power do the shunt reactors cover?

Rated power is 10–210 MVA, from РТМ-10000/220 up to ОРДЦ-210000/500 and ОРЦО-210000/500.

Which HV classes are offered?

The HV classes are 35, 220, 500 and 550 kV. РТМ-65000/550 and РТМ-128000/550 are in the 550 kV class, РТД-20000/35 in the 35 kV class.

What are these reactors used for?

They compensate the charging power of high-voltage transmission lines. The type designation is chosen from the rated power and the HV class.

Other analogues

European analogues of РОДЦ, РОДЦ-110000/750, РОДЦ-60000/500 from other manufacturers and series.

All analogues of РОДЦ · All analogues of РОДЦ-110000/750 · All analogues of РОДЦ-60000/500

Similar equipment from other manufacturers