РТУ and РТДУ (КШР) controlled shunt reactors, 25–180 MVA, HV class 35–500 kV
Controlled shunt reactors РТУ and РТДУ (КШР, also written УШР) for smooth regulation of reactive power and voltage in 35–500 kV networks. Rated power is 25–180 MVA; the HV class is 35, 110, 220, 330, 400 or 500 kV.
- Series
- РТУ, РТДУ
- Rated power
- 25–180 MVA
- HV voltage class
- 35, 110, 220, 330, 400, 500 kV
- Purpose
- Smooth regulation of reactive power and voltage
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Series РТУ and РТДУ are controlled shunt reactors, abbreviated КШР and also written УШР. They regulate reactive power and voltage smoothly in networks of 35–500 kV; in English the type is known as a magnetically controlled shunt reactor (MCSR).
The reactor is classed as a FACTS device. Rated power is 25–180 MVA and the HV class is 35, 110, 220, 330, 400 or 500 kV.
Series РТУ: РТУ-25000/35, РТУ-63000/220 and РТУ-180000/500.
Series РТДУ: РТДУ-60000/220, РТДУ-63000/110 and РТДУ-100000/400.
The reactor forms part of a УШР complex. A single-line flow chart exists for the complex, together with circuit diagrams, one for 220–500 kV and one for 110 kV and below. Static VAR compensators are also built on the basis of the УШР.
Operating experience with the УШР covers the networks of large consumers, 220–110 kV networks, full-scale voltage stabilisation in transmission networks and long high-voltage transits. The specification table lists the type designations, which are chosen by rated power and HV class.
Technical specifications
| Series | РТУ, РТДУ |
|---|---|
| Rated power | 25–180 MVA |
| HV voltage class | 35, 110, 220, 330, 400, 500 kV |
| Purpose | Smooth regulation of reactive power and voltage |
| Networks | 35–500 kV |
| Type designations РТУ | РТУ-25000/35, РТУ-25000/110, РТУ-63000/220, РТУ-180000/330, РТУ-180000/500 |
| Type designations РТДУ | РТДУ-60000/220, РТДУ-63000/110, РТДУ-100000/400 |
European equivalents
Shunt reactors, Shunt reactors, including variable, up to 300 Mvar, BKD / BKS 220–1000 kV oil-immersed shunt reactors, Shunt reactors, Shunt and series reactors, Shunt reactors, Shunt reactors for high-voltage grids, Shunt reactors for high and extra-high voltage up to 500 kV
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
РТУ and РТДУ (КШР) controlled shunt reactors, 25–180 MVA, HV class 35–500 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does a РТУ or РТДУ controlled shunt reactor regulate?
It regulates reactive power and voltage smoothly, in networks of 35–500 kV.
What rated power do the РТУ and РТДУ type designations cover?
Rated power is 25–180 MVA, from РТУ-25000/35 to РТУ-180000/500. Series РТДУ is listed as РТДУ-60000/220, РТДУ-63000/110 and РТДУ-100000/400.
What does УШР mean next to КШР?
УШР is another designation of a controlled shunt reactor. Static VAR compensators are also built on the basis of the УШР.