РТУ and РТДУ (КШР) controlled shunt reactors, 25–180 MVA, HV class 35–500 kV

Controlled shunt reactors РТУ and РТДУ (КШР, also written УШР) for smooth regulation of reactive power and voltage in 35–500 kV networks. Rated power is 25–180 MVA; the HV class is 35, 110, 220, 330, 400 or 500 kV.

Series
РТУ, РТДУ
Rated power
25–180 MVA
HV voltage class
35, 110, 220, 330, 400, 500 kV
Purpose
Smooth regulation of reactive power and voltage

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series РТУ and РТДУ are controlled shunt reactors, abbreviated КШР and also written УШР. They regulate reactive power and voltage smoothly in networks of 35–500 kV; in English the type is known as a magnetically controlled shunt reactor (MCSR).

The reactor is classed as a FACTS device. Rated power is 25–180 MVA and the HV class is 35, 110, 220, 330, 400 or 500 kV.

Series РТУ: РТУ-25000/35, РТУ-63000/220 and РТУ-180000/500.

Series РТДУ: РТДУ-60000/220, РТДУ-63000/110 and РТДУ-100000/400.

The reactor forms part of a УШР complex. A single-line flow chart exists for the complex, together with circuit diagrams, one for 220–500 kV and one for 110 kV and below. Static VAR compensators are also built on the basis of the УШР.

Operating experience with the УШР covers the networks of large consumers, 220–110 kV networks, full-scale voltage stabilisation in transmission networks and long high-voltage transits. The specification table lists the type designations, which are chosen by rated power and HV class.

Technical specifications

SeriesРТУ, РТДУ
Rated power25–180 MVA
HV voltage class35, 110, 220, 330, 400, 500 kV
PurposeSmooth regulation of reactive power and voltage
Networks35–500 kV
Type designations РТУРТУ-25000/35, РТУ-25000/110, РТУ-63000/220, РТУ-180000/330, РТУ-180000/500
Type designations РТДУРТДУ-60000/220, РТДУ-63000/110, РТДУ-100000/400

European equivalents

Shunt reactors, Shunt reactors, including variable, up to 300 Mvar, BKD / BKS 220–1000 kV oil-immersed shunt reactors, Shunt reactors, Shunt and series reactors, Shunt reactors, Shunt reactors for high-voltage grids, Shunt reactors for high and extra-high voltage up to 500 kV

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

РТУ and РТДУ (КШР) controlled shunt reactors, 25–180 MVA, HV class 35–500 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What does a РТУ or РТДУ controlled shunt reactor regulate?

It regulates reactive power and voltage smoothly, in networks of 35–500 kV.

What rated power do the РТУ and РТДУ type designations cover?

Rated power is 25–180 MVA, from РТУ-25000/35 to РТУ-180000/500. Series РТДУ is listed as РТДУ-60000/220, РТДУ-63000/110 and РТДУ-100000/400.

What does УШР mean next to КШР?

УШР is another designation of a controlled shunt reactor. Static VAR compensators are also built on the basis of the УШР.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides