ТДЦ (TDTs) — three-phase oil-immersed power transformer with forced oil and air circulation (DTs) (series)
Voltage transformation in power grids and substations: supplying consumers, linking networks of different voltage classes and exporting power-plant output.
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Voltage transformation in power grids and substations: supplying consumers, linking networks of different voltage classes and exporting power-plant output.
Technical specifications
| Type | Three-phase oil-immersed power transformer with forced oil and air circulation (DTs) |
|---|---|
| Designation | ТДЦ |
Request a price and lead time
ТДЦ. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
European analogues of ТДЦ

Power transformers and autotransformersGenerator step-up transformers (GSU) for power stations, up to 750 MVA, up to 525 kV

Power transformers and autotransformersCore-type power and generator step-up transformers up to 1500 MVA and 1000 kV

Power transformers and autotransformersShell-type power transformers up to 1300 MVA and 765 kV, single- and three-phase

Power transformers and autotransformersOil-immersed power transformers up to 160 MVA, up to 220 kV

Power transformers and autotransformersGenerator step-up transformers, 330–1000 kV, for 300–1000 MW units

Special transformersPumped-storage transformers, 330–500 kV, 420–480 MVA, and 30.7 MVA dry-type SFC units

Special transformersWind farm transformers: platform 220–330 kV, 20 Hz low-frequency, turbine 35–66 kV

Power transformers and autotransformersGrid power transformers with separate windings up to 500 MVA, up to 420 kV

Power transformers and autotransformersGenerator step-up transformers up to 765 kV, three-phase and groups of single-phase units

Special transformersOil-filled power transformers 20 to 600 MVA, 72.5 to 800 kV, 16.7 to 60 Hz

Power transformers and autotransformersOil-filled MV and HV power transformer up to 180 MVA, insulation up to LI 1050 kV

Special transformersGenerator step-up transformers for power plants up to 670 MVA, 400 kV
Generator step-up transformers up to 1510 MVA, autotransformers, gas-insulated typesOil-immersed GSU, PTR and DTR transformers up to 1100 MVA, up to 800 kVPower transformers up to 1,200 kV and 1,500 MVA: GSU, autotransformers, grid and tractionStep-up transformers for HPP, PSPP, TPP, wind farms up to 500 MVA, HV up to 420 kVPower transformers for offshore wind farms, HV 155–225 kV, up to 240 MVA, split LV windingGenerator step-up transformers (GSU) up to 1000 MVA, 550 kV
Analogue selection is for reference only, by purpose and connection dimensions. Before replacement, check the specifications and wiring diagram against the product passport.
Designations of the ТДЦ series
| ТДЦ-125000/110 | rated power (per designation) 125000 kVA; HV winding voltage class 110 kV |
|---|---|
| ТДЦ-250000/220 | rated power (per designation) 250000 kVA; HV winding voltage class 220 kV |
| ТДЦ-400000/330 | rated power (per designation) 400000 kVA; HV winding voltage class 330 kV |