Generator step-up transformers up to 765 kV
Generator step-up transformers for voltages up to 765 kV. They raise the generator voltage of power plants to the transmission network level. They are built as three-phase units and as groups of single-phase transformers.
- Example designs
- 700 MVA 275/20 kV; 590 MVA 420/18.5 kV; group of 3 single-phase units of 360 MVA each at 512.5/20.5/20.5 kV
- Generator voltage
- usually 15–24 kV
- Design
- independent clamping of windings and core
- Production
- Nijmegen, Netherlands
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The generator voltage on the LV side is usually 15–24 kV. Implemented units include 700 MVA 275/20 kV and 590 MVA 420/18.5 kV transformers, as well as a group of 3 single-phase units of 360 MVA each at 512.5/20.5/20.5 kV. The windings and core have independent clamping. Production is in Nijmegen, Netherlands.
Technical specifications
| Example designs | 700 MVA 275/20 kV; 590 MVA 420/18.5 kV; group of 3 single-phase units of 360 MVA each at 512.5/20.5/20.5 kV |
|---|---|
| Generator voltage | usually 15–24 kV |
| Design | independent clamping of windings and core |
| Production | Nijmegen, Netherlands |
Replacement for
ТДЦ-125000/110, ТДЦ-250000/220, ТДЦ-400000/330, ТЦ-630000/500, ОРЦ-533000/500, ОРЦ-417000/750 (generator step-up)
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Generator step-up transformers up to 765 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 23 00 00 |
|---|---|
| HS, 6 digits | 8504 23 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 23 00 |
| HTSUS (USA) | 8504 21 00 20 8504 21 00 40 8504 21 00 60 8504 21 00 80 8504 22 00 40 8504 22 00 80 8504 23 00 41 8504 23 00 45 8504 23 00 80 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 23 11 00 8504 23 12 00 8504 23 13 00 8504 23 21 00 8504 23 29 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
Up to what voltage are generator step-up transformers built?
Up to 765 kV on the HV side, with a generator voltage usually of 15–24 kV.
Can a unit be built as a group of single-phase transformers?
Yes. For example, a group of 3 single-phase units of 360 MVA each at 512.5/20.5/20.5 kV has been supplied.
Which three-phase generator step-up transformers have been built?
Examples include 700 MVA 275/20 kV and 590 MVA 420/18.5 kV.