TOHn are oil-filled distribution and power transformers rated up to 16 MVA with HV up to 35 kV. The typical range is 100–2500 kVA. They are used in distribution networks, industry and power plants.

Power
up to 16 MVA (typical 100–2500 kVA)
HV voltage
up to 35 kV
LV voltage
400/231; 420/242 V
Regulation
±2×2.5 % DETC; OLTC on request

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

LV voltage is 400/231 or 420/242 V. Regulation is ±2×2.5 % DETC, and on request the transformer is built with OLTC, as in the 630 kVA supply for EAM Netz. Transformers rated 12.5 MVA, 22 kV have been built for industrial consumers. Cooling is ONAN, ONAF, KNAN or KNAF, with vector groups Dyn1, Dyn5 and Dyn11. The transformers are built to STN EN 60076 and EN 50708.

Technical specifications

Powerup to 16 MVA (typical 100–2500 kVA)
HV voltageup to 35 kV
LV voltage400/231; 420/242 V
Regulation±2×2.5 % DETC; OLTC on request
CoolingONAN, ONAF, KNAN, KNAF
Vector groupsDyn1, Dyn5, Dyn11
StandardsSTN EN 60076, EN 50708

Replacement for

ТМГ-250/10, ТМГ-400/10, ТМГ-630/10, ТМГ-1000/10, ТМГ-1600/10, ТМГ-2500/10; ТМ-…/10, ТМЗ-…/10; ТМГ-…/35, ТМ-1000/35…ТМ-2500/35, ТМН-4000/35, ТМН-6300/35; ТД-10000/35, ТДНС-10000/35, ТДНС-16000/35

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

TOHn oil-filled distribution and power transformers up to 16 MVA, 35 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 21 00 00
8504 22 10 00
8504 22 90 00
8504 23 00 00
HS, 6 digits8504 22
CN (EU)8504 21 00
8504 22 10
8504 22 90
8504 23 00
HTSUS (USA)8504 21 00 40
8504 21 00 60
8504 21 00 80
8504 22 00 40
8504 22 00 80
8504 23 00 41
China customs tariff8504 21 00 00
8504 22 00 00
8504 23 11 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What power and voltage do TOHn transformers have?

Up to 16 MVA at HV up to 35 kV, with a typical range of 100–2500 kVA.

Can TOHn be ordered with OLTC?

Yes, the standard is DETC ±2×2.5 %, and OLTC on request. For example, a 630 kVA transformer with OLTC was supplied for EAM Netz.

Which cooling types are available?

ONAN, ONAF, KNAN and KNAF.