International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Generator step-up transformers (GSU) up to 1000 MVA, 550 kV

Generator step-up transformers (GSU) rated up to 1000 MVA in three-phase version for voltages up to 550 kV. They raise the voltage of power plant generators to the level of the trunk grid.

Power
up to 1000 MVA (3-phase) / 500 MVA (1-phase)
Voltage
up to 550 kV (BIL 1675 kV)
Regulation
OLTC or DETC on the HV side
Collector step-up (renewables)
up to 500 MVA, up to 345 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Single-phase step-up transformers are made up to 500 MVA, and the insulation level at 550 kV corresponds to BIL 1675 kV. Voltage is regulated by OLTC or DETC on the HV side. For wind and solar farms there are collector step-up transformers up to 500 MVA and up to 345 kV. The equipment works in 50 and 60 Hz networks and is supplied under the manufacturer's own brand.

Technical specifications

Powerup to 1000 MVA (3-phase) / 500 MVA (1-phase)
Voltageup to 550 kV (BIL 1675 kV)
RegulationOLTC or DETC on the HV side
Collector step-up (renewables)up to 500 MVA, up to 345 kV
Frequency50 / 60 Hz

Replacement for

ТДЦ-125000/110, ТДЦ-250000/220, ТДЦ-400000/330, ТЦ-630000/500, ОРЦ-533000/500, ОРЦ-417000/750 (generator unit)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Generator step-up transformers (GSU) up to 1000 MVA, 550 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 23 00 00
HS, 6 digits8504 23
CN (EU)8504 23 00
HTSUS (USA)8504 23 00 80
China customs tariff8504 23 29 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What is the maximum power of a step-up transformer?

Up to 1000 MVA in three-phase version and up to 500 MVA in single-phase. Voltage is up to 550 kV with BIL 1675 kV.

Are there step-up transformers for wind and solar farms?

Yes, collector step-up transformers for wind and solar farms are made up to 500 MVA and up to 345 kV.

Where is the voltage regulation device located?

OLTC or DETC is fitted on the HV side. The transformers are made for 50 and 60 Hz.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides