International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

RZL-50.RPN microprocessor controller for transformer on-load tap changers

The RZL-50.RPN drives the on-load tap changer of a power transformer. It has 4 analog inputs, 8 discrete inputs, 8 relays, an RS-485 port, a digital oscillograph and an event log.

Type
Microprocessor device for automatic control of a transformer on-load tap changer
Controlled transformer
2- or 3-winding power transformer
Analog inputs
4 (UAB, 3U0, Iвв, Iсв)
Discrete inputs
8, optically isolated

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The RZL-50.RPN controls the tap changer drive of a 2- or 3-winding power transformer while it is under load, in automatic, remote and local voltage regulation. By changing the transformation ratio it monitors the voltage level, holds it within the set limits, supervises the tap changer and applies the required interlocking logic.

A digital oscillograph and an event log are built in, and the device connects to SCADA systems over RS-485 using Modbus RTU. Local control and indication are on an OLED display. Operating temperature is -40°C...+60°C. The device acts on the tap changer drive in automatic, remote and local regulation modes, events are written to the log, and fault waveforms are captured by the digital oscillograph. It is intended for power stations and substations of 6-35 kV.

Hardware: 4 analog inputs (UAB, 3U0, Iвв, Iсв), 8 optically isolated discrete inputs and 8 free-purpose relays. Relays K2 and K5 carry extra contacts, and a separate KWD relay is used for signalling.

It is fitted in the relay compartments of КРП and КРПН switchgear at power stations and substations, and on panels and control cabinets in relay rooms and control desks. The case is 170х96х180 mm, 139.2х88.2х177 mm without the front panel, and the mounting window is 143х92 mm. It is flush-mounted: the panel needs a 143х92 mm cut-out and the front panel projects beyond it. Software version is 17.

After storage with the power off, the device should be left energised for at least 1 hour to charge the internal battery that keeps the clock running.

Technical specifications

TypeMicroprocessor device for automatic control of a transformer on-load tap changer
Controlled transformer2- or 3-winding power transformer
Analog inputs4 (UAB, 3U0, Iвв, Iсв)
Discrete inputs8, optically isolated
Relays8 free-purpose (K2 and K5 with extra contacts, KWD signalling)
Communication portRS-485
ProtocolModbus RTU
DisplayOLED
Operating temperature-40°C...+60°C
Dimensions170х96х180 mm
Dimensions without front panel139.2х88.2х177 mm
Mounting window143х92 mm
Software version17

Part numbers

Show all part numbers (1)

RZL-50.RPN

How it compares with similar models

ParameterRZL-50.RPN microprocessor controller for transformer on-load tap changersRZL-400 protection, automation and control terminal for 6-35 kV substations and feedersRZL-100 protection, automation and control device for 6-20 kV substations and feedersRZL-600 protection, automation and control terminal for 6-154 kV substations and feeders
TypeMicroprocessor device for automatic control of a transformer on-load tap changerProtection, automation and control device for substations and feedersProtection, automation and control device for substations and feedersProtection, automation and control device for substations and feeders
Analog inputs4 (UAB, 3U0, Iвв, Iсв)8 (IA, IB, IC, 3I0, UA, UB, UC, 3U0)8 (IA, IB, IC, 3I0, UA, UB, UC, 3U0)8 (IA, IB, IC, 3I0, UA, UB, UC, 3U0)
Discrete inputs8, optically isolated9 (3 dry contact)8 (4 dry contact)21 (including 3 dry contact)
Relays8 free-purpose (K2 and K5 with extra contacts, KWD signalling)8 (5 changeover, 3 make)8 (switching group, including 1 bistable K3 and 1 device integrity relay KWD)17 (8 changeover, 6 make, 1 signalling, 2 double changeover)
Dimensions170х96х180 mm220х207х80.5 mm220х207х80.5 mm270х220х110.5

European equivalents

TAPCON 230 / 250 voltage regulator for transformers with OLTC, SPRECON-E-C-AVR, PROTECTA DTRV/TR, BELplus ARN / BELplus SZR

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

RZL-50.RPN microprocessor controller for transformer on-load tap changers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which transformers does the RZL-50.RPN control?

It controls the on-load tap changer drive of a 2- or 3-winding power transformer, with automatic, remote and local voltage regulation.

What inputs and outputs does it have?

4 analog inputs (UAB, 3U0, Iвв, Iсв), 8 optically isolated discrete inputs and 8 free-purpose relays. Communication is via the RS-485 port using Modbus RTU.

What are the operating temperature range and dimensions?

-40°C to +60°C. The device measures 170х96х180 mm and needs a 143х92 mm mounting window.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides