The RZL-100 is a protection, automation, control and signalling device for 6-20 kV feeders that needs no external auxiliary supply. It has 8 analog inputs, 8 discrete inputs, 8 relays, RS-485 and Ethernet ports.

Type
Protection, automation and control device for substations and feeders
Voltage class
6-20 kV
External auxiliary supply
not required
Analog inputs
8 (IA, IB, IC, 3I0, UA, UB, UC, 3U0)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The RZL-100 series is a new line of protection and automation devices for 6-20 kV feeders, covering relay protection, automation, control and signalling. No external auxiliary power source is needed. The devices serve as main or backup protection in power systems.

Typical duties are protection of 6-20 kV overhead and cable lines, incoming and section breakers, and backup protection of transformers. A digital oscillograph and an event log are included, with backup power from current transformer circuits, arc protection on fibre optic sensors and desolenoiding of breaker trip coils. SCADA integration runs over RS-485 and Ethernet RJ-45 using Modbus RTU and Modbus TCP.

Hardware: 8 analog inputs (IA, IB, IC, 3I0, UA, UB, UC, 3U0), 8 discrete inputs (4 of them dry contact), a switching group of 8 relays including one bistable relay K3 and a device integrity relay KWD, and 3 fibre optic inputs for arc protection sensors. The display is OLED. The case is 220х207х80.5 mm and the operating temperature is -40°C...+60°C.

Versions: the RZL-100.1-В (У) is basic, with no current circuit power, no desolenoiding and no fibre optic inputs. The RZL-100.2-В (У) is extended, with current circuit power and desolenoiding but no fibre optic inputs. The RZL-100.3-В (У) is full: current circuit power, desolenoiding and 3 fibre optic inputs, with 3 sensors supplied. In the designation the letter У stands for flush mounting and В for surface mounting.

After storage with the power off, leave the device energised for at least 1 hour to charge the internal battery that keeps the clock running.

Technical specifications

TypeProtection, automation and control device for substations and feeders
Voltage class6-20 kV
External auxiliary supplynot required
Analog inputs8 (IA, IB, IC, 3I0, UA, UB, UC, 3U0)
Discrete inputs8 (4 dry contact)
Relays8 (switching group, including 1 bistable K3 and 1 device integrity relay KWD)
Fibre optic inputs3 (for arc protection sensors)
Communication portsRS-485, Ethernet RJ-45
ProtocolsModbus RTU, Modbus TCP
DisplayOLED
Operating temperature-40°C...+60°C
Dimensions220х207х80.5 mm

Part numbers

Show all part numbers (3)

RZL-100.1-V (У), RZL-100.2-V (У), RZL-100.3-V (У)

How it compares with similar models

ParameterRZL-100 protection, automation and control device for 6-20 kV substations and feedersRZL-400 protection, automation and control terminal for 6-35 kV substations and feedersRZL-600 protection, automation and control terminal for 6-154 kV substations and feedersRZL-50.RPN microprocessor controller for transformer on-load tap changers
TypeProtection, automation and control device for substations and feedersProtection, automation and control device for substations and feedersProtection, automation and control device for substations and feedersMicroprocessor device for automatic control of a transformer on-load tap changer
Voltage class6-20 kV6-35 kV6-154 kV—
Analog inputs8 (IA, IB, IC, 3I0, UA, UB, UC, 3U0)8 (IA, IB, IC, 3I0, UA, UB, UC, 3U0)8 (IA, IB, IC, 3I0, UA, UB, UC, 3U0)4 (UAB, 3U0, Iвв, Iсв)
Discrete inputs8 (4 dry contact)9 (3 dry contact)21 (including 3 dry contact)8, optically isolated
Relays8 (switching group, including 1 bistable K3 and 1 device integrity relay KWD)8 (5 changeover, 3 make)17 (8 changeover, 6 make, 1 signalling, 2 double changeover)8 free-purpose (K2 and K5 with extra contacts, KWD signalling)
Fibre optic inputs3 (for arc protection sensors)3, in versions .3 and .63 (cable length 5 m)—

European equivalents

BELplus OZE, IRV MV feeder protection terminal (V platform), PROTECTA DTIVA, SPR10

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

RZL-100 protection, automation and control device for 6-20 kV substations and feeders. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the RZL-100 need an external power source?

No. The series needs no external auxiliary supply and draws power from current circuits in the versions that include it (RZL-100.2 and RZL-100.3).

How do RZL-100.1, .2 and .3 differ?

The RZL-100.1 is basic: no current circuit power, no desolenoiding, no fibre optic inputs. The RZL-100.2 adds current circuit power and desolenoiding, and the RZL-100.3 also has 3 fibre optic inputs with 3 sensors included.

Which interfaces and protocols does the RZL-100 have?

RS-485 and Ethernet RJ-45 ports, with Modbus RTU and Modbus TCP protocols for SCADA integration.